Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
2.
Europace ; 21(1): 147-153, 2019 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-30016418

RESUMEN

AIMS: Left ventricular (LV) outflow tract ventricular arrhythmias (OTVA) are associated with hypertension (HT), older age, and LV dysfunction, suggesting that LV overload plays a role in the aetiopathogenesis. We hypothesized that anatomical modifications of the LV outflow tract (LVOT) could predict left vs. right OTVA site of origin (SOO). METHODS AND RESULTS: Fifty-six (32 men, 53 ± 18 years old) consecutive patients referred for OTVA ablation were included. Cardiac multidetector computed tomography was performed before ablation and then imported to the CARTO system to aid the mapping and ablation procedure. Anatomical characteristics of the aortic root as well as aortopulmonary valvular planar angulation (APVPA) were analysed. The LV was the OTVA SOO (LVOT-VA) in 32 (57%) patients. These patients were more frequently male (78% vs. 22%, P = 0.001), older (57 ± 18 vs. 47 ± 18 years, P = 0.055), and more likely to have HT (59% vs. 21%, P = 0.004), compared to right OTVA patients. Aortopulmonary valvular planar angulation was higher in LVOT-VA patients (68 ± 5° vs. 55 ± 6°, respectively; P < 0.001). Absolute size of all aortic root diameters was associated with LVOT origin. However, after indexing by body surface area, only sinotubular junction diameter maintained a significant association (P = 0.049). Multivariable analysis showed that APVPA was an independent predictor of LVOT origin. Aortopulmonary valvular planar angulation ≥62° reached 94% sensitivity and 83% specificity (area under the curve 0.95) for predicting LVOT origin. CONCLUSIONS: The measurement of APVPA as a marker of chronic LV overload is useful for the prediction of left vs. right ventricular OTVA origin.


Asunto(s)
Ventrículos Cardíacos/diagnóstico por imagen , Tomografía Computarizada Multidetector , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda , Función Ventricular Derecha , Complejos Prematuros Ventriculares/etiología , Remodelación Ventricular , Potenciales de Acción , Adulto , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Femenino , Frecuencia Cardíaca , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/fisiopatología , Factores de Riesgo , Disfunción Ventricular Izquierda/complicaciones , Disfunción Ventricular Izquierda/fisiopatología , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/fisiopatología , Complejos Prematuros Ventriculares/cirugía
3.
Europace ; 20(2): 337-346, 2018 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-28017938

RESUMEN

Aims: Identification of local abnormal electrograms (EGMs) during ventricular tachycardia substrate ablation (VTSA) is challenging when they are hidden within the far-field signal. This study analyses whether the response to a double ventricular extrastimulus during substrate mapping could identify slow conducting areas that are hidden during sinus rhythm. Methods and results: Consecutive patients (n = 37) undergoing VTSA were prospectively included. Bipolar EGMs with >3 deflections and duration <133 ms were considered as potential hidden slow conduction EGMs (HSC-EGM) if located within/surrounding the scar area. Whenever a potential HSC-EGM was identified, a double ventricular extrastimulus was delivered. If the local potential delayed, it was annotated as HSC-EGM. The incidence of HSC-EGM in core, border-zone, and normal-voltage regions was determined. Ablation was delivered at conducting channel entrances and HSC-EGMs. VT inducibility after VTSA obtained was compared with data from a historic control group. 2417 EGMs were analyzed. 575 (23.7%) qualified as potential HSC-EGM, and 198 of them were tagged as HSC-EGMs. Scars in patients with HSC-EGMs (n = 21, 56.7%) were smaller (35.424.7 vs 67.639.1 cm2; P = 0.006) and more heterogeneous (core/scar area ratio 0.250.2 vs 0.450.19; P = 0.02). 28.8% of HSC-EGMs were located in normal-voltage tissue; 81.3% were targeted for ablation. Patients undergoing VTSA incorporating HSC analysis needed less radiofrequency time (17.411 vs 2310.7 minutes; P = 0.016) and had a lower rate of VT inducibility after VTSA than the historic controls (24.3% vs 50%; P = 0.018). Conclusion: Ventricular tachycardia substrate ablation incorporating HSC analysis allowed further arrhythmic substrate identification (especially in normal-voltage areas) and reduced RF time and VT inducibility after VTSA.


Asunto(s)
Estimulación Cardíaca Artificial , Técnicas Electrofisiológicas Cardíacas , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca , Taquicardia Ventricular/diagnóstico , Potenciales de Acción , Anciano , Ablación por Catéter , Femenino , Sistema de Conducción Cardíaco/cirugía , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Valor Predictivo de las Pruebas , Estudios Prospectivos , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/cirugía , Factores de Tiempo , Resultado del Tratamiento
4.
Europace ; 20(3): 512-519, 2018 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-28069835

RESUMEN

Aims: Ventricular tachycardia (VT) substrate ablation is based on detailed electroanatomical maps (EAM). This study analyses whether high-density multielectrode mapping (MEM) is superior to conventional point-by-point mapping (PPM) in guiding VT substrate ablation procedures. Methods and results: This was a randomized controlled study (NCT02083016). Twenty consecutive ischemic patients undergoing VT substrate ablation were randomized to either group A [n = 10; substrate mapping performed first by PPM (Navistar) and secondly by MEM (PentaRay) ablation guided by PPM] or group B [n = 10; substrate mapping performed first by MEM and second by PPM ablation guided by MEM]. Ablation was performed according to the scar-dechanneling technique. Late potential (LP) pairs were defined as a Navistar-LP and a PentaRay-LP located within a three-dimensional distance of ≤ 3 mm. Data obtained from EAM, procedure time, radiofrequency time, and post-ablation VT inducibility were compared between groups. Larger bipolar scar areas were obtained with MEM (55.7±31.7 vs. 50.5±26.6 cm2; P = 0.017). Substrate mapping time was similar with MEM (19.7±7.9 minutes) and PPM (25±9.2 minutes); P = 0.222. No differences were observed in the number of LPs identified within the scar by MEM vs. PPM (73±50 vs. 76±52 LPs per patient, respectively; P = 0.965). A total of 1104 LP pairs were analysed. Using PentaRay, far-field/LP ratio was significantly lower (0.58±0.4 vs. 1.64±1.1; P = 0.01) and radiofrequency time was shorter [median (interquartile range) 12 (7-20) vs. 22 (17-33) minutes; P = 0.023]. No differences were observed in VT inducibility after procedure. Conclusion: MEM with PentaRay catheter provided better discrimination of LPs due to a lower sensitivity for far-field signals. Ablation guided by MEM was associated with a shorter radiofrequency time.


Asunto(s)
Cateterismo Cardíaco/métodos , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas , Sistema de Conducción Cardíaco/cirugía , Taquicardia Ventricular/cirugía , Potenciales de Acción , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Técnicas Electrofisiológicas Cardíacas/instrumentación , Femenino , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Tempo Operativo , Proyectos Piloto , Valor Predictivo de las Pruebas , España , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
5.
J Interv Card Electrophysiol ; 28(2): 71-80, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20390331

RESUMEN

PURPOSE: Desmin mutations in humans cause desmin-related cardiomyopathy, resulting in heart failure, atrial and ventricular arrhythmias, and sudden cardiac death. The intermediate filament desmin is strongly expressed in striated muscle cells and in Purkinje fibers of the ventricular conduction system. The aim of the present study was to characterize electrophysiological cardiac properties in a desmin-deficient mouse model. METHODS: The impact of desmin deficiency on cardiac electrophysiological characteristics was examined in the present study. In vivo electrophysiological studies were carried out in 29 adult desmin deficient (Des-/-) and 19 wild-type (Des+/+) mice. Additionally, epicardial activation mapping was performed in Langendorff-perfused hearts. RESULTS: Intracardiac electrograms showed no significant differences in AV, AH, and HV intervals. Functional testing revealed equal AV-nodal refractory periods, sinus-node recovery times, and Wenckebach points. However, compared to the wild-type situation, Des-/- mice were found to have a significantly reduced atrial (23.6+/-10.3 ms vs. 31.8+/-12.5 ms; p=0.045), but prolonged ventricular refractory period (33.0+/-8.7 ms vs. 26.7+/-6.5 ms; p=0.009). The probability of induction of atrial fibrillation was significantly higher in Des-/- mice (Des-/-: 38% vs. Des+/+: 27%; p=0.0255), while ventricular tachycardias significantly were reduced (Des-/-: 7% vs. Des+/+: 21%; p<0.0001). Epicardial activation mapping showed slowing of conduction in the ventricles of Des-/- mice. CONCLUSIONS: Des-/- mice exhibit reduced atrial but prolonged ventricular refractory periods and ventricular conduction slowing, accompanied by enhanced inducibility of atrial fibrillation and diminished susceptibility to ventricular arrhythmias. Desmin deficiency does not result in electrophysiological changes present in human desminopathies, suggesting that functional alterations rather than loss of desmin cause the cardiac alterations in these patients.


Asunto(s)
Sistema de Conducción Cardíaco/fisiopatología , Animales , Fibrilación Atrial/fisiopatología , Desmina/deficiencia , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Genotipo , Frecuencia Cardíaca/fisiología , Ratones , Ratones Endogámicos C57BL
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA