BMC Neurol ; 23(1): 5, 2023 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-36604639

RESUMEN

PURPOSE: The treatment of vasospasms during endovascular stroke treatment (EST) with intra-arterial nimodipine (NM) is routinely performed. However, the efficacy of resolving iatrogenic vasospasms during the angiographic intervention and the infarct development in follow-up imaging after EST has not been studied yet. METHODS: Retrospective single-center analysis of patients receiving EST for anterior circulation vessel occlusion between 01/2015 and 12/2021. The primary endpoint was ASPECTS in follow-up imaging. Secondary endpoints were the clinical outcome (combined endpoint NIHSS 24 h after EST and difference between modified Rankin Scale (mRS) before stroke and at discharge (delta mRS)) and intracranial hemorrhage (ICH) in follow-up imaging. Patients with vasospasms receiving NM (NM+) or not (NM-) were compared in univariate analysis. RESULTS: Vasospasms occurred in 79/1283 patients (6.2%), who consecutively received intra-arterial NM during EST. The targeted vasospasm angiographically resolved in 84% (66/79) under NM therapy. ASPECTS was lower in follow-up imaging after vasospasms and NM-treatment (NM - 7 (6-9), NM + 6 (4.5-8), p = 0.013) and the clinical outcome was worse (NIHSS 24 h after EST was higher in patients treated with NM (median, IQR; NM+: 14, 5-21 vs. NM-: 9, 3-18; p = 0.004), delta-mRS was higher in the NM + group (median, IQR; NM+: 3, 1-4 vs. NM-: 2, 1-2; p = 0.011)). Any ICH (NM+: 27/79, 34.2% vs. NM-: 356/1204, 29.6%; p = 0.386) and symptomatic ICH (NM+: 2/79, 2.5% vs. NM-: 21/1204, 1.7%; p = 0.609) was equally distributed between groups. CONCLUSION: Intra-arterial nimodipine during EST resolves iatrogenic vasospasms efficiently during EST without increasing intracranial hemorrhage rates. However, patients with vasospasms and NM treatment show higher infarct growth resulting in lower ASPECTS in follow-up imaging.


Asunto(s)
Enfermedades del Sistema Nervioso Autónomo , Isquemia Encefálica , Procedimientos Endovasculares , Accidente Cerebrovascular , Humanos , Nimodipina/uso terapéutico , Estudios Retrospectivos , Estudios de Seguimiento , Resultado del Tratamiento , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/tratamiento farmacológico , Accidente Cerebrovascular/etiología , Hemorragias Intracraneales/etiología , Trombectomía/métodos , Enfermedades del Sistema Nervioso Autónomo/etiología , Infarto/etiología , Enfermedad Iatrogénica , Procedimientos Endovasculares/métodos , Isquemia Encefálica/tratamiento farmacológico
2.
Cardiovasc Intervent Radiol ; 42(6): 905-914, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30761410

RESUMEN

PURPOSE: To investigate the novel zein-based non-adhesive precipitating liquid embolic HEIE1_2017. MATERIALS AND METHODS: Zein-based liquid embolics are an own class of embolization material. In this study, HEIE1_2017, a novel zein-based liquid embolic, was investigated. Visibility was assessed in vitro in CT and MRI phantoms, embolization characteristics were assessed in vivo in the kidneys of 12 pigs. Components of HEIE1_2017 were zein as occlusion material, ethanol as solvent, and iodized oil as radiopaque material. HEIE1_2017 was used in pure (HEI-PURE) and manually modified (HEI-MOD) form and compared with 6% ethylene vinyl alcohol copolymer (EVOH). Different radiological methods (CT, MRI, DSA, cone-beam CT, and micro-CT) and histopathologic analyses were applied to compare visibility and vascular occlusion patterns. RESULTS: In CT phantoms, all embolics were definitely visible as hyperdense materials. In MRI phantoms, signal-to-noise ratio was highest for HEI-PURE, followed by HEI-MOD and EVOH. In all kidneys, embolization procedures were technically successful and without complications. In DSA, all embolics were definitely visible during and after embolization. Only EVOH caused substantial artifacts in cone-beam CT and CT. In micro-CT and histopathology, HEI-PURE showed a homogeneous occlusion from segmental arteries to glomerular capillaries. HEI-MOD demonstrated the deepest vascular penetration (up to the level of peritubular capillaries), but with an inhomogeneous distribution. For EVOH, there was inhomogeneous vascular occlusion from segmental arteries to glomerular capillaries. CONCLUSION: HEIE1_2017 is a promising novel zein-based liquid embolic. Further preclinical and clinical studies with higher case numbers and long-term follow-up are needed to further assess the value of this embolic material.


Asunto(s)
Quimioembolización Terapéutica/métodos , Diatrizoato de Meglumina/administración & dosificación , Etanol/administración & dosificación , Riñón/diagnóstico por imagen , Propilenglicol/administración & dosificación , Zeína/administración & dosificación , Angiografía de Substracción Digital , Animales , Artefactos , Aceite Yodado , Imagen por Resonancia Magnética/métodos , Modelos Animales , Fantasmas de Imagen , Radiografía , Porcinos , Tomografía Computarizada por Rayos X , Rayos X
3.
J Neurointerv Surg ; 10(3): 268-274, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28689184

RESUMEN

BACKGROUND: The choice of the embolic agent and the embolization technique can have a significant impact on the success of endovascular embolization. OBJECTIVE: To evaluate a novel iodinated copolymer-based liquid embolic agent (precipitating hydrophobic injectable liquid (PHIL)) in the porcine rete mirabile (RM), serving as an endovascular embolization model. Onyx, as an established liquid embolic agent, served as comparator. MATERIALS AND METHODS: Sixteen embolization procedures were performed using PHIL (n=8) or Onyx (n=8) as liquid embolic agent. Waiting time between injections was set to 30 or 60 s (n=4 per study group). Survival time after intervention was 2 hours or 7 days. Embolization characteristics (eg, procedure times, number of injections and volume of embolic agent) and embolization extent (percentage of embolized RM in post-interventional x-ray) were assessed. Post-interventional CT and histopathological analyses were performed. RESULTS: Embolization characteristics and embolization extent were not significantly different for PHIL and Onyx, including subgroups (eg, embolization extent 44% vs 69% (medians); p=0.101). For PHIL, extension of the waiting time from 30 to 60 s led to a significantly higher embolization extent (24% vs 72% (medians); p=0.035). Moderate disintegration and mild inflammation of the embolized blood vessels were present for both embolic agents. CONCLUSION: PHIL is feasible for transarterial embolization in an acute and subacute endovascular embolization model. In this preliminary experimental in vivo study, embolization characteristics, embolization extent, and biocompatibility seem to be similar to those of Onyx.


Asunto(s)
Modelos Animales de Enfermedad , Embolización Terapéutica/métodos , Procedimientos Endovasculares/métodos , Malformaciones Arteriovenosas Intracraneales/diagnóstico por imagen , Malformaciones Arteriovenosas Intracraneales/terapia , Polivinilos/administración & dosificación , Animales , Dimetilsulfóxido/administración & dosificación , Evaluación Preclínica de Medicamentos/métodos , Radiografía Intervencional/métodos , Porcinos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS