Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
JACC Cardiovasc Interv ; 10(9): 879-888, 2017 05 08.
Artículo en Inglés | MEDLINE | ID: mdl-28473110

RESUMEN

OBJECTIVES: This study sought to evaluate the incidence and clinical effect of coronary chronic total occlusions (CTOs) in patients with ischemic cardiomyopathy receiving an implantable cardioverter-defibrillator (ICD) for secondary prevention of sudden cardiac death (SCD). BACKGROUND: CTOs are common in patients with ischemic cardiomyopathy, which is the major cause of SCD. However, the impact of CTO in SCD survivors receiving an ICD is unknown. METHODS: A total of 425 patients who had survived an episode of ventricular arrhythmias and underwent ICD implantation for secondary prevention in 8 centers were included. Coronary angiogram, CTO angiographic characteristics, and ventricular arrhythmia pattern were centrally analyzed. Primary and secondary endpoints were appropriate ICD therapies and mortality during a median follow-up of 4.1 years, according to the presence of CTO in the baseline angiogram. RESULTS: Appropriate ICD therapies were higher in patients with CTO (51.7% vs. 36.3%; p = 0.001 at 4 years). Left ventricular ejection fraction (LVEF) (p = 0.015) and CTO (p = 0.001) were independent predictors of appropriate ICD therapy. Ventricular arrhythmia onset was associated to a shorter coupling interval and lower prematurity index in CTO patients. Defibrillator therapies were independently associated with worse LVEF (p = 0.046) and renal dysfunction (p = 0.023) among patients with CTO, and a tendency was observed in patients with better collateral flow (p = 0.093). Patients with poorer renal function (p = 0.029), LVEF (p = 0.041), and CTO (p = 0.033) experienced higher mortality rate. CONCLUSIONS: Among ICD recipients for secondary prevention of SCD, coronary CTO conferred a higher risk of VA recurrence and mortality in long-term follow-up. Angiographic and VA patterns could provide insights into the mechanisms of SCD and may have implications for the use of interventions designed to limit ICD shocks in this high-risk population.


Asunto(s)
Arritmias Cardíacas/terapia , Angiografía Coronaria , Oclusión Coronaria/diagnóstico por imagen , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Técnicas Electrofisiológicas Cardíacas , Prevención Secundaria/instrumentación , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Enfermedad Crónica , Oclusión Coronaria/mortalidad , Muerte Súbita Cardíaca/etiología , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Europa (Continente)/epidemiología , Femenino , Humanos , Incidencia , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Modelos de Riesgos Proporcionales , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
2.
Int J Cardiol ; 177(2): 448-54, 2014 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-25443245

RESUMEN

BACKGROUND: There is great variability for the type of anaesthesia used during TAVI, with no clear consensus coming from comparative studies or guidelines. We sought to detect regional differences in the anaesthetic management of patients undergoing transcatheter aortic valve implantation (TAVI) in Europe and to evaluate the relationship between type of anaesthesia and in-hospital and 1 year outcome. METHODS: Between January 2011 and May 2012 the Sentinel European TAVI Pilot Registry enrolled 2807 patients treated via a transfemoral approach using either local (LA-group, 1095 patients, 39%) or general anaesthesia (GA-group, 1712 patients, 61%). RESULTS: A wide variation in LA use was evident amongst the 10 participating countries. The use of LA has increased over time (from a mean of 37.5% of procedures in the first year, to 57% in last 6 months, p<0.01). MI, major stroke as well as in-hospital death rate (7.0% LA vs 5.3% GA, p=0.053) had a similar incidence between groups, confirmed in multivariate regression analysis after adjusting for confounders. Dividing our population in tertiles according to the Log-EuroSCORE we found similar mortality under LA, whilst mortality was higher in the highest risk tertile under GA. Survival at 1 year, compared by Kaplan-Meier analysis, was similar between groups (log-rank: p=0.1505). CONCLUSIONS: Selection of anaesthesia appears to be more influenced by national practice and operator preference than patient characteristics. In the absence of an observed difference in outcomes for either approach, there is no compelling argument to suggest that operators and centres should change their anaesthetic practice.


Asunto(s)
Anestesia General/métodos , Anestesia Local/métodos , Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Anestesia General/mortalidad , Anestesia Local/mortalidad , Estenosis de la Válvula Aórtica/mortalidad , Femenino , Humanos , Masculino , Proyectos Piloto , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
3.
Eur Heart J Cardiovasc Imaging ; 15(1): 32-40, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23751506

RESUMEN

OBJECTIVES: The aim of this study was to examine the feasibility of transthoracic two-dimensional (2D)-echocardiography in defining the cavo-tricuspid isthmus (CTI) anatomy and its value concerning the ease of catheter ablation of isthmic atrial flutter (AF). METHODS: CTI analysis was accomplished in 39 cases: 16 necropsy specimens and 23 patients. Sixteen were patients with isthmus-dependent AF and seven controls with other supraventricular re-entrant tachycardias. Two-dimensional transthoracic echocardiography and a right atrium angiogram were performed before radiofrequency catheter ablation (RFCA). RESULTS: The measurements of the CTI with angiography were compared with those taken with echocardiography and correlation was excellent (r= 0.91; P < 0.0001). In normal patients, the dimension of the vestibular thickness was successfully compared and validated with the histological examination of the necropsy specimens: histology median 6.8 mm, range 4.4-10.5 vs. echo median 6.2 mm, range 5.4-8.7; P: NS. Vestibular thickness was greater in complex than in simple RFCA (13.6 ± 1.9 mm vs. 10.0 ± 2.3 mm; P = 0.01). When vestibular thickness ≥11.5 mm, the ablation prone to be complex (sensitivity 83.3%, specificity 80%, positive predictive value 71.4%, and negative predictive value 88.9%). CONCLUSIONS: Two-dimensional transthoracic echocardiography clearly depicts the inferior isthmus and, displaying the thickness of the tricuspid vestibule, it was related with complexity of the ablation procedure in isthmus-dependent AF.


Asunto(s)
Aleteo Atrial/diagnóstico por imagen , Aleteo Atrial/cirugía , Ablación por Catéter/métodos , Ecocardiografía , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Anciano , Aleteo Atrial/patología , Cadáver , Angiografía Coronaria , Técnicas Electrofisiológicas Cardíacas , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad , Taquicardia Supraventricular/diagnóstico por imagen , Resultado del Tratamiento , Válvula Tricúspide/patología
4.
Heart Rhythm ; 11(1): 8-14, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24103221

RESUMEN

BACKGROUND: Results from randomized trials designed to compare cryoenergy with radiofrequency for pulmonary vein (PV) isolation are lacking. OBJECTIVE: To compare the efficacy of a simplified strategy for PV cryoablation (group C) vs PV isolation with open-irrigated radiofrequency catheters (group R). METHODS: Fifty patients with paroxysmal atrial fibrillation (AF) and 4 independent PVs received a Reveal XT implantable cardiac monitor and were randomized to group C or group R. In group C, PV ablation was done with a single Arctic Front balloon (23 or 28 mm) per patient and two 300-second applications per PV. No further applications were delivered to close residual conduction gaps. In group R, bidirectional PV conduction block was pursued with Lasso and Navistar ThermoCool catheters and the CARTO system. The primary end point was the proportion of patients remaining free from AF recurrences ≥2 minutes without taking antiarrhythmic drugs 12 months after ablation. RESULTS: The primary end point was met by 12 (48%) patients in group C and 25 (68%) patients in group R (odds ratio 0.43; P = .05). This difference disappeared after adjustment for acute procedural outcome. In patients for whom all 4 PVs were blocked at the end of the procedure, there was no difference between group C and group R in the primary end point (67% vs 68%; P = .94). CONCLUSIONS: The efficacy of the simplified strategy for PV cryoablation tested in this study is inferior to PV isolation using open-irrigated radiofrequency catheters with electrophysiological and electroanatomical guidance. Complete PV conduction block is critical to the success of AF ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Criocirugía/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Sistema de Conducción Cardíaco/cirugía , Monitoreo Fisiológico/métodos , Venas Pulmonares/cirugía , Adolescente , Adulto , Anciano , Fibrilación Atrial/fisiopatología , Femenino , Estudios de Seguimiento , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca/fisiología , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Taquicardia Paroxística/fisiopatología , Taquicardia Paroxística/cirugía , Resultado del Tratamiento , Adulto Joven
5.
EuroIntervention ; 8 Suppl P: P90-3, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22917800

RESUMEN

Early reperfusion of the occluded artery is the mainstay of the treatment of ST-segment elevation myocardial infarction (STEMI), and the best way to coordinate the resources to deliver optimal care as soon as possible is through STEMI networks. Coordination of the healthcare system is the responsibility of each of the 17 different autonomous communities in Spain. Since 2002, when the first STEMI network in Spain was established, six other communities have developed regional networks, covering 39% of the population in Spain. In the autonomous communities, after implementing an intervention model, an improvement in the reperfusion times with an increase in the number of primary percutaneous coronary interventions has been observed. This optimisation of the system has resulted in a decrease in the mortality rate among STEMI patients treated in Spanish communities with a STEMI network. Despite the encouraging advances, the challenge remains of assuring equity of treatment for all of our patients regardless of their region of residence.


Asunto(s)
Prestación Integrada de Atención de Salud/organización & administración , Accesibilidad a los Servicios de Salud/organización & administración , Planificación Hospitalaria/organización & administración , Infarto del Miocardio/terapia , Intervención Coronaria Percutánea , Prestación Integrada de Atención de Salud/normas , Accesibilidad a los Servicios de Salud/normas , Planificación Hospitalaria/normas , Humanos , Modelos Organizacionales , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/mortalidad , Objetivos Organizacionales , Intervención Coronaria Percutánea/normas , Guías de Práctica Clínica como Asunto , Desarrollo de Programa , Evaluación de Programas y Proyectos de Salud , España , Factores de Tiempo , Tiempo de Tratamiento/organización & administración , Resultado del Tratamiento
7.
J Cardiovasc Electrophysiol ; 17(6): 662-9, 2006 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16836719

RESUMEN

INTRODUCTION: Atrial fibrillation (AF) may be triggered by ectopic beats originating in sleeves of atrial myocardium entering the pulmonary veins (PVs). PV isolation by means of circumferential ostial or atrial radiofrequency ablation is an effective but also a difficult and long procedure, requiring extensive applications that can have serious potential complications. Our objective was to examine pathological effects of PV beta-radiation, particularly the ability to destroy PV myocardial sleeves without inducing PV stenosis and other unwanted effects, in order to establish its potential feasibility for the treatment of AF. METHODS AND RESULTS: Ten minipigs were studied. A phosphorus-32 source wire centered within a 2.5-mm diameter balloon catheter (Galileo III Intravascular Radiotherapy System, Guidant, Santa Clara, CA, USA) was used to deliver beta-radiation to the superior wall of the right PV trunk. Pathological analysis was performed either immediately after ablation (2 pigs) or 81 +/- 27 days later (8 pigs). Acute effects of PV beta-radiation consisted of endothelial denudation covered by white thrombus, elastic lamina disruption, and PV sleeve necrosis. Late effects consisted of mild focal neointimal hyperplasia that reduced the PV luminal area by only 1.3 +/- 1.8%, elastic lamina thickening, and PV sleeve fibrosis. Four of these 8 PVs were completely re-endothelized. Lesions were transmural in 6 of 10 radiated PVs and segmental, involving 28 +/- 7% of the right PV perimeter. CONCLUSION: Intravascular beta-radiation can induce transmural necrosis and fibrosis of PV myocardial sleeves without PV stenosis and other unwanted effects, which supports a potential usefulness of this energy source in the treatment of AF.


Asunto(s)
Braquiterapia , Ablación por Catéter/métodos , Venas Pulmonares/efectos de la radiación , Animales , Fibrilación Atrial/radioterapia , Fibrilación Atrial/cirugía , Partículas beta , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Estudios de Factibilidad , Modelos Animales , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/patología , Radiografía , Porcinos , Porcinos Enanos
8.
Rev. esp. cardiol. Supl. (Ed. impresa) ; 6(supl.D): 38d-51d, 2006. graf, tab
Artículo en Español | IBECS | ID: ibc-166103

RESUMEN

Los ácidos grasos poliinsaturados n-3 u omega-3 son una prometedora terapia dietética preventiva para la enfermedad cardiovascular, y constituyen un método seguro y efectivo para la prevención de la muerte súbita. El pescado graso es la fuente dietética principal de ácidos grasos poliinsaturados n-3. En los últimos años, las propiedades antiarrítmicas de estos ácidos grasos han sido extensamente investigadas. Se han propuesto y estudiado varios mecanismos para explicar este efecto antiarrítmico, pero hasta el momento ninguno de ellos ha sido validado de forma definitiva. En esta revisión se resumen los conocimientos epidemiológicos que sostienen el uso de los ácidos grasos n-3 con esta indicación, la evidencia básica y clínica alcanzada en estudios experimentales en animales y humanos, así como las teorías actuales sobre el mecanismo antiarrítmico de esta clase de ácidos grasos poliinsaturados (AU)


Dietary n-3 or omega-3 polyunsaturated fatty acids show promise as preventive therapy for cardiovascular disease, offering a safe and effective means of reducing sudden death. Oily fish is the main dietary source of omega-3 polyunsaturated fatty acid. In recent years, the anti-arrhythmic effects of polyunsaturated fatty acids have been extensively investigated. Several mechanisms that could explain these antiarrhythmic effects have been proposed and have been investigated. However, to date, no definitive mechanism has been identified. This review summarizes the epidemiological data supporting the use of omega-3 fatty acids in this context, the preclinical and clinical evidence revealed by animal and human studies, and current hypotheses about the antiarrhythmic mechanism of this class of polyunsaturated fatty acid (AU)


Asunto(s)
Humanos , Arritmias Cardíacas/tratamiento farmacológico , Taquicardia Supraventricular/tratamiento farmacológico , Ácidos Grasos Omega-3/administración & dosificación , Ácidos Grasos Omega-3/farmacología , Aceites de Pescado/administración & dosificación , Muerte Súbita/prevención & control , Muerte Súbita Cardíaca/prevención & control , Electrofisiología/métodos , Electrofisiología/tendencias , Prevención Primaria/métodos , Prevención Secundaria/métodos
9.
J Cardiovasc Electrophysiol ; 13(8): 750-6, 2002 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-12212691

RESUMEN

INTRODUCTION: Radiofrequency (RF) ablation of accessory pathways (APs) is often a time-consuming procedure, mainly because conventional criteria have modest accuracy. Thus, additional mapping criteria are desirable. Our hypothesis was that comparison of paced atrial activation sequences with that obtained during orthodromic AV reentrant tachycardia might be useful for locating the atrial insertion of single APs. METHODS AND RESULTS: The study included 15 patients with a single AP referred for ablation. Analysis of the atrial activation sequence was simplified by measuring the activation time (AT) that elapsed between two atrial reference points placed next to the AV annulus on either side of the area containing the AP. Ablation was guided by conventional criteria. Before each RF delivery, a short pacing train was delivered from the ablation catheter and, after verification of atrial capture, the AT was compared with the AT obtained during orthodromic tachycardia. Fifty sites of RF delivery were appropriate for analysis. The multivariate model with the highest predictive power included a deviation of AT between pacing and tachycardia < or = 5 msec (P < 0.001), a local AV ratio > or = 1 (P = 0.04), and stability of the local electrogram (P = 0.05). The combination of all these criteria predicted a successful application with high sensitivity, specificity, and positive predictive value (92%, 86%, and 71% respectively). To validate the method prospectively, 10 additional consecutive patients underwent an AP ablation procedure guided by these criteria. CONCLUSION: This technique seems to be highly accurate in selecting the atrial site for RF ablation of single APs.


Asunto(s)
Nervio Accesorio/patología , Nervio Accesorio/cirugía , Mapeo del Potencial de Superficie Corporal , Estimulación Cardíaca Artificial , Ablación por Catéter , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/terapia , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos/patología , Atrios Cardíacos/cirugía , Sistema de Conducción Cardíaco/patología , Sistema de Conducción Cardíaco/cirugía , Humanos , Modelos Logísticos , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Taquicardia por Reentrada en el Nodo Atrioventricular/epidemiología , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA