Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Am J Clin Oncol ; 43(9): 628-635, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32889832

RESUMEN

OBJECTIVES: Stereotactic body radiation treatment represents an intriguing therapeutic option for patients with early-stage prostate cancer. In this phase II study, stereotactic body radiation treatment was delivered by volumetric modulated arc therapy with flattening filter free beams and was gated using real-time electromagnetic transponder system to maximize precision of radiotherapy and, potentially, to reduce toxicities. MATERIALS AND METHODS: Patients affected by histologically proven prostate adenocarcinoma and National Comprehensive Cancer Network (NCCN) intermediate class of risk were enrolled in this phase II study. Beacon transponders were positioned transrectally within the prostate parenchyma 7 to 10 days before simulation computed tomography scan. The radiotherapy schedule was 38 Gy in 4 fractions delivered every other day. Toxicity assessment was performed according to Common Terminology Criteria for Adverse Events (CTCAE), v4.0. RESULTS: Thirty-six patients were enrolled in this study. Median initial prostate-specific antigen was 7.0 ng/mL (range: 2.3 to 14.0 ng/mL). Median nadir-prostate-specific antigen after treatment was 0.2 ng/mL (range: 0.006 to 4.8 ng/mL). A genitourinary acute toxicity was observed in 21 patients (dysuria grade [G] 1: 41.7%, G2: 16.7%). Gastrointestinal acute toxicity was found in 9 patients (proctitis G1: 19.4%, G2: 5.6%). Late toxicity was mild (genitourinary toxicity G1: 30.6%; G2: 8.3%; gastrointestinal toxicity G1: 13.9%; G2: 19.4%). At a median follow-up time of 41 months, 3 biochemical recurrences were observed (2 local recurrences, 1 distant metastasis). Three-year biochemical recurrence-free survival was 89.8% (International Society of Urologic Pathology Grade Group 2: 100%, Grade Group 3: 77.1%, P=0.042). CONCLUSION: Ultrahypofractionated radiotherapy, delivered with flattening filter free-volumetric modulated arc therapy and gated by electromagnetic transponders, is a valid option for intermediate-risk prostate cancer.


Asunto(s)
Adenocarcinoma/radioterapia , Recurrencia Local de Neoplasia/sangre , Neoplasias de la Próstata/radioterapia , Radiocirugia/métodos , Radioterapia de Intensidad Modulada , Adenocarcinoma/secundario , Anciano , Diarrea/etiología , Supervivencia sin Enfermedad , Fraccionamiento de la Dosis de Radiación , Disuria/etiología , Fenómenos Electromagnéticos , Humanos , Masculino , Persona de Mediana Edad , Nocturia/etiología , Proctitis/etiología , Antígeno Prostático Específico/sangre , Neoplasias de la Próstata/patología , Traumatismos por Radiación/etiología , Radiocirugia/efectos adversos , Radioterapia de Intensidad Modulada/efectos adversos
2.
Strahlenther Onkol ; 196(7): 608-616, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32303782

RESUMEN

INTRODUCTION: Stereotactic body radiation therapy (SBRT) is considered an effective and safe treatment in patients with low- and intermediate-risk prostate cancer (PC). However, due to a lack of long-term follow-up and late toxicity data, this treatment is not universally accepted. The present study aimed to evaluate outcome and early and late toxicity in a cohort of patients with low- and intermediate-risk PC treated prospectively with linear accelerator (linac)-based SBRT. PATIENTS AND METHODS: Patients with low- or intermediate-risk (NCCN criteria) PC were included. All patients received linac-based SBRT to 35 Gy in 5 fractions delivered on alternate days. Endpoints were toxicity, biochemical relapse-free survival (BRFS), metastatic progression-free survival (mPFS), and overall survival (OS). RESULTS: From 2012 to 2018, 178 patients were treated. Median baseline prostate-specific antigen (iPSA) was 6.37 ng/ml (range 1.78-20). Previous transurethral resection of the prostate (TURP) was present in 23 (12.9%) patients. Median follow-up was 58.9 months (range 9.7-89.9). BRFS rates at 1, 3, and 5 years were 98.3 (95% confidence interval, CI, 94.7-99.4%), 94.4 (95%CI 89.4-97), and 91.6% (95%CI 85.4-95.2), respectively. In univariate analysis, performance status (PS), iPSA, and nadir PSA (nPSA) were correlated with BRFS. In multivariable analysis iPSA and nPSA remained significant. BRFS rates at 5 years were 94.9% (95%CI 86.8-98) for International Society of Urological Pathology (ISUP) grade group 1, 93.2% (95%CI 80.5-97.7) for ISUP group 2, and 74.8% (95%CI 47.1-89.5) for ISUP group 3. At 1, 3, and 5 years, mPFS rates were 98.8 (95%CI 95.5-99.7), 96.2 (95%CI 91.9-98.3), and 92.9% (95%CI 87.2-96.2), respectively; OS rates were 100, 97.2 (95%CI 92.9-98.9), and 95.1% (95%CI 90-97.6), respectively. One (0.56%) case of grade 3 acute genitourinary (GU), one case of acute gastrointestinal (GI), and one case of grade 3 late GU toxicity were observed. GI toxicity positively correlated with prostate volume. CONCLUSION: At long-term follow-up, linac-based SBRT continues to be a valid option for the management localized PC. Biochemical control remains high at 5 years, albeit with some concerns regarding the optimal schedule for unfavorable intermediate-risk PC. Considering the excellent prognosis, patient selection is crucial for prevention of severe late toxicity.


Asunto(s)
Adenocarcinoma/radioterapia , Neoplasias de la Próstata/radioterapia , Radiocirugia/métodos , Adenocarcinoma/sangre , Adenocarcinoma/patología , Adenocarcinoma/cirugía , Anciano , Anciano de 80 o más Años , Terapia Combinada , Fraccionamiento de la Dosis de Radiación , Enfermedades Gastrointestinales/etiología , Ultrasonido Enfocado de Alta Intensidad de Ablación , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Tamaño de los Órganos , Aceleradores de Partículas , Supervivencia sin Progresión , Antígeno Prostático Específico/sangre , Neoplasias de la Próstata/sangre , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/cirugía , Radiocirugia/efectos adversos , Factores de Riesgo , Resección Transuretral de la Próstata , Resultado del Tratamiento , Carga Tumoral , Trastornos Urinarios/etiología
3.
Phys Med ; 38: 45-53, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28610696

RESUMEN

PURPOSE: The increasing interest in SBRT treatments encourages the use of flattening filter free (FFF) beams. Aim of this work was to evaluate the performance of the PTW60019 microDiamond detector under 6MV and 10MVFFF beams delivered with the EDGE accelerator (Varian Medical System, Palo Alto, USA). A flattened 6MV beam was also considered for comparison. METHODS: Short term stability, dose linearity and dose rate dependence were evaluated. Dose per pulse dependence was investigated in the range 0.2-2.2mGy/pulse. MicroDiamond profiles and output factors (OFs) were compared to those obtained with other detectors for field sizes ranging from 40×40cm2 to 0.6×0.6cm2. In small fields, volume averaging effects were evaluated and the relevant correction factors were applied for each detector. RESULTS: MicroDiamond short term stability, dose linearity and dependence on monitor unit rate were less than 0.8% for all energies. Response variations with dose per pulse were found within 1.8%. MicroDiamond output factors (OF) values differed from those measured with the reference ion-chamber for less than 1% up to 40×40cm2 fields where silicon diodes overestimate the dose of ≈3%. For small fields (<3×3cm2) microDiamond and the unshielded silicon diode were in good agreement. CONCLUSIONS: MicroDiamond showed optimal characteristics for relative dosimetry even under high dose rate beams. The effects due to dose per pulse dependence up to 2.2mGy/pulse are negligible. Compared to other detectors, microDiamond provides accurate OF measurements in the whole range of field sizes. For fields <1cm correction factors accounting for fluence perturbation and volume averaging could be required.


Asunto(s)
Diamante , Fotones , Radiometría/instrumentación , Radiocirugia , Silicio
4.
Anticancer Res ; 36(7): 3451-7, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27354607

RESUMEN

BACKGROUND/AIM: Radiotherapy is a common approach for treating squamous cell carcinoma (SCC) of the oropharynx. We aimed to analyze toxicity and outcome of patients affected by oropharyngeal SCC treated with volumetric modulated arc therapy (VMAT). PATIENTS AND METHODS: Fifty-four patients presenting advanced orophayngeal carcinoma who were treated with radical radiotherapy were analyzed. All patients were treated with VMAT-RapidArc, with simultaneous integrated boost in 33 fractions for a dose of 69.96 Gy to the high-risk, and of 54.45 Gy to the low-risk volume. RESULTS: Median follow-up was 23 months. In eight cases, locoregional relapse was observed (median time to relapse=10.7 months). Four among eight local recurrences appeared in the high-dose target volume. The 1- and 2-year actuarial disease-free survival rates were 88% and 80%, respectively. The 1- and 2-year actuarial overall survival rates were 94% and 87%, respectively. CONCLUSION: VMAT for oropharyngeal SCC treatment is effective and safe, with interesting rates of control of disease and survival.


Asunto(s)
Carcinoma de Células Escamosas/radioterapia , Neoplasias Orofaríngeas/radioterapia , Radioterapia de Intensidad Modulada/efectos adversos , Adulto , Anciano , Anciano de 80 o más Años , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Carboplatino/administración & dosificación , Carcinoma de Células Escamosas/mortalidad , Cetuximab/administración & dosificación , Quimioradioterapia , Cisplatino/administración & dosificación , Fraccionamiento de la Dosis de Radiación , Femenino , Fluorouracilo/administración & dosificación , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Neoplasias Orofaríngeas/mortalidad , Radiodermatitis/etiología , Resultado del Tratamiento , Xerostomía/etiología
5.
Phys Med Biol ; 56(6): 1879-904, 2011 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-21364257

RESUMEN

A new algorithm, Acuros® XB Advanced Dose Calculation, has been introduced by Varian Medical Systems in the Eclipse planning system for photon dose calculation in external radiotherapy. Acuros XB is based on the solution of the linear Boltzmann transport equation (LBTE). The LBTE describes the macroscopic behaviour of radiation particles as they travel through and interact with matter. The implementation of Acuros XB in Eclipse has not been assessed; therefore, it is necessary to perform these pre-clinical validation tests to determine its accuracy. This paper summarizes the results of comparisons of Acuros XB calculations against measurements and calculations performed with a previously validated dose calculation algorithm, the Anisotropic Analytical Algorithm (AAA). The tasks addressed in this paper are limited to the fundamental characterization of Acuros XB in water for simple geometries. Validation was carried out for four different beams: 6 and 15 MV beams from a Varian Clinac 2100 iX, and 6 and 10 MV 'flattening filter free' (FFF) beams from a TrueBeam linear accelerator. The TrueBeam FFF are new beams recently introduced in clinical practice on general purpose linear accelerators and have not been previously reported on. Results indicate that Acuros XB accurately reproduces measured and calculated (with AAA) data and only small deviations were observed for all the investigated quantities. In general, the overall degree of accuracy for Acuros XB in simple geometries can be stated to be within 1% for open beams and within 2% for mechanical wedges. The basic validation of the Acuros XB algorithm was therefore considered satisfactory for both conventional photon beams as well as for FFF beams of new generation linacs such as the Varian TrueBeam.


Asunto(s)
Fotones/uso terapéutico , Radiometría/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Agua/química , Algoritmos , Anisotropía , Humanos , Modelos Biológicos , Dosificación Radioterapéutica
6.
Phys Med ; 26(1): 44-8, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19356958

RESUMEN

Exposures to the extremities have increased due to new therapeutic protocols involving beta sources. In this study, thermoluminescent dosimeters based on alpha-Al(2)O(3):C were used to map the dose distribution to the extremities of physicians and paramedical personnel handling beta emitters. The results showed a strong inhomogeneous dose distribution between different phalanxes, fingers and hands of all the investigated subjects, without an indication of systematic trends in the dose patterns. Consequently, conventional dosimetric practices, based on the use of wrist or ring dosimeters, may be not suitable for providing reliable assessments of the inhomogeneous doses received at the fingertip.


Asunto(s)
Partículas beta , Dedos , Mano , Exposición Profesional , Dosis de Radiación , Dosimetría Termoluminiscente/instrumentación , Óxido de Aluminio , Compuestos Inorgánicos de Carbono , Estudios de Factibilidad , Física Sanitaria , Humanos , Cuerpo Médico de Hospitales , Médicos , Estudios Retrospectivos
7.
Radiat Prot Dosimetry ; 113(4): 359-65, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-15788418

RESUMEN

The angular dependence of the thermoluminescent (TL) signal of thin alpha-Al2O3:C dosemeters was investigated for a series of beta-emitting radionuclides commonly employed in nuclear medicine and characterised by different mean energies (99Tc, 177Lu, 90Sr/90Y and 90Y). Irradiations were performed in a controlled geometry, using a properly designed irradiator intended to realistically reproduce the situation of exposure of hospital personnel to beta-emitting pharmaceuticals. Under the conditions of extended source and short source to detector distance, the TL signal of thin alpha-Al2O3:C layers per unit irradiation time was observed to be independent on the angle of incidence within acceptable limits, particularly for those radionuclides with maximum energy >500 keV. This property may be easily explained by using simple physical considerations, such as the limited thickness of the dosemeters. The results confirm that these detectors are suitable for beta-ray extremity dose measurements, when the photon contribution is negligible, as in the case considered.


Asunto(s)
Dosimetría Termoluminiscente/instrumentación , Dosimetría Termoluminiscente/métodos , Aluminio , Óxido de Aluminio/química , Partículas beta , Método de Montecarlo , Fotones , Dosis de Radiación , Radioisótopos/química , Radiometría/instrumentación , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA