Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Analyst ; 148(4): 772-779, 2023 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-36661384

RESUMEN

In this study, for the first time, a silver-based metal-organic framework (Ag-MOF) was synthesized and used as the electrochemiluminescence (ECL) emitter for building an ECL sensor. After modification with chitosan (CS) and gold nanoparticles (Au NPs), the ECL stability of Ag-MOF was improved. To detect mercury ions, a biosensor was constructed using the mercury ion aptamer and steric effect of streptavidin. First, the capture strand (cDNA) with terminal-modified sulfhydryl group was attached to the electrode surface by the Au-S bond. Then, the mercury-ion aptamer (Apt-Hg) modified with biotin was anchored to the electrode by complementary pairing with cDNA. Streptavidin (SA) could be fixed on the electrode by linking with biotin, thereby reducing the ECL signal. However, in the presence of mercury ions, the aptamer was removed and streptavidin could not be immobilized on the electrode. Hence, the ECL signal of the sensor increased with the concentration of mercury ions, which was linear in the range from 1 µM to 300 fM. The detection limit could reach 66 fM (S/N = 3). The sensor provided a new method for the detection of mercury ions.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Mercurio , Nanopartículas del Metal , Biotina/química , Estreptavidina/química , Plata , ADN Complementario , Oro/química , Técnicas Electroquímicas/métodos , Nanopartículas del Metal/química , Mediciones Luminiscentes/métodos , Aptámeros de Nucleótidos/química , Iones , Técnicas Biosensibles/métodos , Límite de Detección
2.
Anal Chim Acta ; 1048: 42-49, 2019 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-30598156

RESUMEN

A novel enhanced photoelectrochemical (PEC) DNA biosensor, based on a compact heterojunction g-C3N4/MoS2 and co-sensitization effect with CdSe quantum dots (QDs), was first proposed for simple and accurate analysis of a short ssDNA. In this work, the g-C3N4/MoS2 was successfully synthesized and used as the electrode matrix material to construct PEC biosensor. 2D/2D heterojunction was formed between g-C3N4 and MoS2, which could promote the separation of photogenerated electron-hole pairs resulting in an enhanced photocurrent. In the presence of target DNA, CdSe QDs labeled reporter DNA was complementary pairing with target DNA which was specific recognized by capture DNA loading on self-assembled CdS QDs film, leading to close contact between CdSe QDs and g-C3N4/MoS2 modified electrode surface, thereby resulting in the enhanced photocurrent intensity due to the co-sensitization effect. Under the optimal operating conditions, the photoelectrochemical biosensor demonstrated favorable accuracy and could respond to 0.32 pM (S/N = 3) with a linear concentration range from 1.0 pM to 2.0 µM. Moreover, the proposed PEC DNA biosensor exhibits high sensitivity, excellent specificity, acceptable reproducibility and accuracy, showing a promising potential in DNA bioanalysis and other relative fields.


Asunto(s)
Técnicas Biosensibles/métodos , ADN de Cadena Simple/análisis , Técnicas Electroquímicas/métodos , Fotoquímica/métodos , Puntos Cuánticos/química , Compuestos de Cadmio/química , Compuestos de Cadmio/efectos de la radiación , ADN de Cadena Simple/genética , Disulfuros/química , Electrodos , Luz , Límite de Detección , Molibdeno/química , Nitrilos/química , Hibridación de Ácido Nucleico , Puntos Cuánticos/efectos de la radiación , Compuestos de Selenio/química , Compuestos de Selenio/efectos de la radiación
3.
Biosens Bioelectron ; 103: 99-103, 2018 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-29288884

RESUMEN

An electrochemical biosensor was developed based on a steric hindrance hybridization assay to allow the highly sensitive detection of streptavidin. In the steric hindrance hybridization assay, the signaling strand DNA (sig-DNA) was labeled at the 3' end with CdSe quantum dots (QDs) and at the 5' end with biotin, and capturing strand DNA (the complementary strand of sig-DNA) was labeled at the 5' end with thiol. The steric hindrance effect generated by streptavidin which was bound with the signaling DNA strand. The streptavidin limited the ability of the sig-DNA to hybridize with the cap-DNA, which were linked on the surface of a gold electrode. Therefore, the concentration of streptavidin was detected indirectly based on the concentration of CdSe QDs on the electrode surface. The concentration of CdSe QDs on the electrode surface was detected by differential pulse anodic stripping voltammetry. Under optimal conditions, the streptavidin detection range using the as-prepared biosensor was 1.96pg/mL to 1.96µg/mL and the detection limit was 0.65pg/mL. The experimental results showed that the electrochemical biosensor could detect streptavidin rapidly and accurately.


Asunto(s)
Técnicas Biosensibles/métodos , Compuestos de Cadmio/aislamiento & purificación , ADN/química , Técnicas Electroquímicas , Compuestos de Selenio/aislamiento & purificación , Compuestos de Cadmio/toxicidad , Oro/química , Límite de Detección , Hibridación de Ácido Nucleico/genética , Puntos Cuánticos/química , Compuestos de Selenio/toxicidad , Estreptavidina/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA