Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Heart Rhythm ; 19(1): 102-112, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34534699

RESUMEN

BACKGROUND: Detailed effects of electrode size on electrograms (EGMs) have not been systematically examined. OBJECTIVES: We aimed to elucidate the effect of electrode size on EGMs and investigate an optimal configuration of electrode size and interelectrode spacing for gap detection and far-field reduction. METHODS: This study included 8 sheep in which probes with different electrode size and interelectrode spacing were epicardially placed on healthy, fatty, and lesion tissues for measurements. Between 3 electrode sizes (0.1 mm/0.2 mm/0.5 mm) with 3 mm spacing. As indices of capability in gap detection and far-field reduction, in different electrode sizes (0.1 mm/0.2 mm/0.5 mm) and interelectrode spacing (0.1 mm/0.2 mm/0.3 mm/0.5 mm/3 mm) and the optimized electrode size and interelectrode spacing were determined. Compared between PentaRay and the optimal probe determined in study 2. RESULTS: Study 1 demonstrated that unipolar voltage and the duration of EGMs increased as the electrode size increased in any tissue (P < .001). Bipolar EGMs had the same tendency in healthy/fat tissues, but not in lesions. Study 2 showed that significantly higher gap to lesion volume ratio and healthy to fat tissue voltage ratio were provided by a smaller electrode (0.2 mm or 0.3 mm electrode) and smaller spacing (0.1 mm spacing), but 0.3 mm electrode/0.1 mm spacing provided a larger bipolar voltage (P < .05). Study 3 demonstrated that 0.3 mm electrode/0.1 mm spacing provided less deflection with more discrete EGMs (P < .0001) with longer and more reproducible AF cycle length (P < .0001) compared to PentaRay. CONCLUSION: Electrode size affects both unipolar and bipolar EGMs. Catheters with microelectrodes and very small interelectrode spacing may be superior in gap detection and far-field reduction. Importantly, this electrode configuration could dramatically reduce artifactual complex fractionated atrial electrograms and may open a new era for AF mapping.


Asunto(s)
Electrodos , Técnicas Electrofisiológicas Cardíacas/instrumentación , Animales , Ablación por Catéter , Modelos Animales de Enfermedad , Diseño de Equipo , Femenino , Oveja Doméstica
2.
J Interv Card Electrophysiol ; 60(2): 313-319, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32621214

RESUMEN

BACKGROUND: High-density automated mapping of complex atrial tachycardias (ATs) requires accurate assessment of activation maps. A new local activation display module (HD coloring, Biosense Webster®) provides higher map resolution, a better delineation of potential block reducing color interpolation, and a new propagation display. We evaluated the accuracy of a dedicated local activation display compared with standard algorithm. METHODS: High-density maps from 10 AT were collected with a multipolar catheter and were displayed with standard activation or HD coloring. Six expert operators retrospectively analyzed activation maps and were asked to define (1) the tachycardia mechanism, (2) ablation target, and (3) level of difficulty to interpret those maps. RESULTS: Using HD coloring, operators were able to reach a correct diagnosis in 93% vs. 63%, p < 0.05 compared to standard activation maps. Time to diagnosis was shorter 1.9 ± 1.0 min vs. 3.9 ± 2.1 min, p < 0.05. Confidence level would have allowed ablation without necessity for entrainment maneuvers in 87% vs. 53%, p < 0.05. Operators would have needed to remap or proceed with multiple entrainments in 3% vs. 13% of cases, p < 0.05. Finally, ablation strategy was more accurately identified in 97% vs. 67%, p < 0.05. CONCLUSION: Activation mapping with the new HD coloring module allowed a more accurate, reliable, and faster interpretation of complex ATs mechanisms compared to standard activation maps.


Asunto(s)
Ablación por Catéter , Taquicardia Supraventricular , Técnicas Electrofisiológicas Cardíacas , Humanos , Estudios Retrospectivos , Taquicardia , Taquicardia Supraventricular/diagnóstico por imagen , Taquicardia Supraventricular/cirugía
3.
Heart Rhythm ; 16(11): 1661-1668, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31207315

RESUMEN

BACKGROUND: Wall thickness (WT) in post-myocardial infarction scar is heterogenous, with channels of relatively preserved thickness bordered by thinner scar. OBJECTIVE: This study sought to determine whether 3-dimensionally-reconstructed computed tomography (CT) channels correlate with electrophysiological isthmuses during ventricular tachycardia (VT). METHODS: We retrospectively studied 9 postinfarction patients (aged 57 ± 15 years, 1 female) with 10 complete VT activation maps (cycle length 429 ± 77ms) created using high-resolution mapping. Three-dimensionally-reconstructed WT maps from CT were merged with the activation map during sinus rhythm (SR) and VT. The relationship between WT and electrophysiological characteristics was analyzed. RESULTS: A total of 41 CT channels were identified (median 4 per patient), of median (range) length 21.2 mm (17.3-36.8 mm), width 9.0 mm (6.7-16.5 mm), and area 1.49 cm2(1.00-1.75 cm2). WT in the channel was significantly thicker in the center than in the edge (median 2.4 mm vs 1.5 mm, P < .0001). Of 3163 (2493-5960) mapping points in SR, 382 (191-1115) local abnormal ventricular activities (LAVAs) were identified. One patient had a maximal proportion of LAVAs in 3-4 mm, 3 patients in 2-3 mm, 2 in 1-2 mm, and 2 in 0-1 mm. The VT isthmuses of all 10 VTs corresponded with 1-4 CT channels. Twenty-one of the 41 CT channels (51.2%) corresponded to a VT isthmus (entrance, mid, or exit). Electrophysiological VT isthmuses were more likely to be associated with CT channels that were longer (P = .04, odds ratio [OR] 1.05/mm), thinner (but not less than 1 mm) (P = .03, OR 0.36/mm), or parallel to the mitral annulus (P = .07, OR 3.93). CONCLUSION: VT isthmuses were always found in CT channels (100% sensitivity), and half of CT channels hosted VT isthmuses (positive predictive value 51%). Longer and thinner (but >1 mm) CT channels were significantly associated with VT isthmuses.


Asunto(s)
Infarto del Miocardio/complicaciones , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/etiología , Tomografía Computarizada por Rayos X/métodos , Cicatriz/fisiopatología , Medios de Contraste , Técnicas Electrofisiológicas Cardíacas , Femenino , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
4.
Circ Arrhythm Electrophysiol ; 12(6): e007293, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-31122054

RESUMEN

Background Catheter ablation of ventricular tachycardia (VT) in structural heart disease is challenging because of noninducibility or hemodynamic compromise. Ablation often depends on elimination of local abnormal ventricular activities (LAVAs) but which may be hidden in far-field signal. We investigated whether altering activation wavefront affects activation timing and LAVA characterization and allows a better understanding of isthmus anatomy. Methods Patients with ischemic cardiomyopathy underwent mapping using the ultra-high density Rhythmia system (Boston Scientific). Maps were generated for all stable VTs and with pacing from the atrium, right ventricular apex, and an left ventricular branch of the coronary sinus. Results Fifty-six paced maps and 23 VT circuits were mapped in 22 patients. In 79% of activation maps, there was ≥1 line of block in the paced conduction wavefront, with 93% having fixed block and 32% showing functional partial block. Bipolar scar was larger with atrial than right ventricular (31.7±18.5 versus 27.6±16.3 cm2, P=0.003) or left ventricular pacing (31.7±18.5 versus 27.0±19.2 cm2, P=0.009); LAVA areas were smaller with atrial than right ventricular (12.3±10.5 versus 18.4±11.0 cm2, P<0.001) or left ventricular pacing (12.3±10.5 versus 17.1±10.7 cm2, P<0.001). LAVA areas were larger with wavefront propagation perpendicular versus parallel to the line of block along isthmus boundaries (19.3±7.1 versus 13.6±7.4 cm2, P=0.01). All patients had successful VT isthmus ablation. In 11±8 months follow-up, 2 patients had a recurrence. Conclusions Wavefronts of conduction slowing/block may aid identification of critical isthmuses in unmappable VTs. Altering the activation wavefront leads to significant differences in conduction properties of myocardial tissue, along with scar and LAVA characterization. In patients where few LAVAs are identified during substrate mapping, using an alternate activation wavefront running perpendicular to the VT isthmus may increase sensitivity to detect arrhythmogenic substrate and critical sites for reentry.


Asunto(s)
Potenciales de Acción , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Ventrículos Cardíacos/cirugía , Taquicardia Ventricular/cirugía , Anciano , Estimulación Cardíaca Artificial , Ablación por Catéter/efectos adversos , Femenino , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Recurrencia , Factores de Riesgo , Volumen Sistólico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda
5.
JACC Clin Electrophysiol ; 5(4): 470-479, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-31000101

RESUMEN

OBJECTIVES: This study reports the use of a novel "Lumipoint" algorithm in ventricular tachycardia (VT) ablation. BACKGROUND: Automatic mapping systems aid rapid acquisition of activation maps. However, they may annotate farfield rather than nearfield signal in low voltage areas, making maps difficult to interpret. The Lumipoint algorithm analyzes the complete electrogram tracing and therefore includes nearfield signals in its analysis. METHODS: Twenty-two patients with ischemic cardiomyopathy and 5 with dilated cardiomyopathy underwent mapping using the ultra-high density Rhythmia system. Lumipoint algorithms were applied retrospectively. RESULTS: In all left ventricular substrate maps, changing the window of interest to the post-QRS phase automatically identified late potentials. In 25 of 27 left ventricular VT activation maps, a minimum spatial window of interest correctly identified the VT isthmus as seen by the manually annotated map, entrainment, and response to ablation. In 6 maps, the algorithm identified the isthmus where the standard automatically annotated map did not. CONCLUSIONS: The Lumipoint algorithm automatically highlights areas with electrograms having specific characteristics or timings. This can identify late and fractionated potentials and regions that exhibit discontinuous activation, as well as the isthmus of a VT circuit. These features may enhance human interpretation of the electrogram signals during a case, particularly where the circuit lies in partial scar with low amplitude nearfield signals and potentially allow a more targeted ablation strategy.


Asunto(s)
Algoritmos , Técnicas Electrofisiológicas Cardíacas/métodos , Ventrículos Cardíacos/fisiopatología , Taquicardia Ventricular/diagnóstico , Anciano , Ablación por Catéter , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/cirugía
6.
Heart Rhythm ; 16(4): 553-561, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30389441

RESUMEN

BACKGROUND: Ablation of complex atrial tachycardias (ATs) is difficult. OBJECTIVE: The purpose of this study was to elucidate a mechanism underlying the behavior of ATs during ablation and to create an algorithm to predict it. METHODS: An algorithm predicting termination/conversion of AT and the second AT circuit associated with the ablation site was developed from 52 index reentrant AT high-resolution activation maps in 45 patients (retrospective phase). First, the wavefront collision site was identified. Then, the N or N-1 beat was defined for each collision associated with the ablation site. When the AT involved wavefront collision solely between N-1/N-1 (N/N) beats, the AT would terminate during ablation. Conversely, when the AT included wavefront collision between N/N-1 beats, the index AT would convert to a second AT. The algorithm was then prospectively tested in 172 patients with 194 ATs (127 anatomic macroreentrant ATs [AMATs], 44 non-AMATs, 23 multiple-loop ATs). RESULTS: Accuracy in predicting AT termination/conversion and the second AT circuit was 95.9% overall, 96.1% in AMATs, 95.5% in non-AMATs, and 95.7% in multiple-loop ATs. Median (25th-75th percentile) absolute variation between predicted and actually observed cycle length of the second AT was 6 (4-9) ms. Prediction failure occurred in 8 ATs; either the second AT used an unmapped chamber or structure in the index map (n = 7) or a line of block was misinterpreted as very slow conduction in the index map (n = 1). CONCLUSION: A simple mechanism underlies the behavior of ATs during ablation, even in complex ATs. With a simple algorithm using high-resolution mapping, AT termination/conversion and the second AT circuit and cycle length may be predicted from the index activation map.


Asunto(s)
Ablación por Catéter , Sistema de Conducción Cardíaco/fisiopatología , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Algoritmos , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Taquicardia por Reentrada en el Nodo Atrioventricular/clasificación
7.
Circ Arrhythm Electrophysiol ; 11(7): e006120, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-30002064

RESUMEN

BACKGROUND: Sudden cardiac death because of ventricular fibrillation (VF) is commonly unexplained in younger victims. Detailed electrophysiological mapping in such patients has not been reported. METHODS: We evaluated 24 patients (29±13 years) who survived idiopathic VF. First, we used multielectrode body surface recordings to identify the drivers maintaining VF. Then, we analyzed electrograms in the driver regions using endocardial and epicardial catheter mapping during sinus rhythm. Established electrogram criteria were used to identify the presence of structural alterations. RESULTS: VF occurred spontaneously in 3 patients and was induced in 16, whereas VF was noninducible in 5. VF mapping demonstrated reentrant and focal activities (87% versus 13%, respectively) in all. The activities were dominant in one ventricle in 9 patients, whereas they had biventricular distribution in others. During sinus rhythm areas of abnormal electrograms were identified in 15/24 patients (62.5%) revealing localized structural alterations: in the right ventricle in 11, the left ventricle in 1, and both in 3. They covered a limited surface (13±6 cm2) representing 5±3% of the total surface and were recorded predominantly on the epicardium. Seventy-six percent of these areas were colocated with VF drivers (P<0.001). In the 9 patients without structural alteration, we observed a high incidence of Purkinje triggers (7/9 versus 4/15, P=0.033). Catheter ablation resulted in arrhythmia-free outcome in 15/18 patients at 17±11 months follow-up. CONCLUSIONS: This study shows that localized structural alterations underlie a significant subset of previously unexplained sudden cardiac death. In the other subset, Purkinje electrical pathology seems as a dominant mechanism.


Asunto(s)
Potenciales de Acción , Muerte Súbita Cardíaca/etiología , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Ramos Subendocárdicos/fisiopatología , Fibrilación Ventricular/diagnóstico , Adolescente , Adulto , Estimulación Cardíaca Artificial , Ablación por Catéter , Causas de Muerte , Muerte Súbita Cardíaca/prevención & control , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Supervivencia sin Progresión , Ramos Subendocárdicos/cirugía , Factores de Riesgo , Factores de Tiempo , Fibrilación Ventricular/complicaciones , Fibrilación Ventricular/fisiopatología , Fibrilación Ventricular/prevención & control , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA