Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
2.
Europace ; 15(3): 414-9, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23385050

RESUMEN

AIMS: The aim of the study was to assess the impact of isthmus location of atypical atrial flutters/atrial tachycardias (ATs) on outcomes of catheter ablation. Atrial tachycardias are clinically challenging arrhythmias that can occur in the presence of atrial scar--often due to either cardiac surgery or prior ablation for atrial fibrillation. We previously demonstrated a catheter ablation approach employing rapid multielectrode activation mapping with targeted entrainment manoeuvrs. However, the role that AT isthmus location plays in acute and long-term success of ablation remains uncertain. METHODS AND RESULTS: Retrospective multicenter analysis of 91 consecutive AT patients undergoing ablation using a systematic four-step approach: (i) high-density activation mapping; (ii) analysis of atrial activation to identify wavefronts of electrical propagation; (iii) targeted entrainment of putative channels; and (iv) irrigated radiofrequency ablation of constrained regions of the circuit. Clinical outcomes, procedural details, and clinical profiles were determined. A total of 171 ATs (1.9 ± 1.0 per patient, 26% septal ATs) were targeted for ablation. The acute success rates were 97 and 77% for patients with either non-septal ATs or septal ATs, respectively (P = 0.0023). Similarly, the long-term success rates were 82 and 67% for patients with either no septal ATs or at least one septal AT, respectively (P = 0.1057). The long-term success rates were 75, 88, and 57% for patients with ATs associated with prior catheter ablation, cardiac surgery or MAZE, and idiopathic atrial scar, respectively. CONCLUSION: Catheter ablation of AT can be successfully performed employing a strategy of combined high-density activation and entrainment mapping. Septal ATs are associated with higher rates of acute and long-term recurrences.


Asunto(s)
Aleteo Atrial/cirugía , Ablación por Catéter , Cicatriz/complicaciones , Taquicardia Supraventricular/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Aleteo Atrial/diagnóstico , Aleteo Atrial/etiología , Ablación por Catéter/efectos adversos , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Modelos de Riesgos Proporcionales , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/etiología , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos , Adulto Joven
3.
Europace ; 15(3): 339-46, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23148118

RESUMEN

AIMS: Although complex fractionated atrial electrograms (CFAEs) are purported to represent critical sites for atrial fibrillation (AF) perpetuation, the mechanism and the significance of CFAE in the genesis of AF remain poorly understood. This study evaluated the relationship between CFAE and areas of abnormal atrial tissue defined by low-voltage electrograms (LVE) and signal average of the P-wave (SAPW). METHODS AND RESULTS: Complex fractionated atrial electrogram maps were obtained after pulmonary vein isolation in 15 patients with persistent AF. Patients were then cardioverted and voltage/activation maps were acquired in normal sinus rhythm (NSR). Total left atrium (LA), CFAE and LVE areas were measured as % of total LA area (mean ± SD). Conduction velocities of normal, LVE and CFAE areas were also measured during NSR. Patients underwent signal averaged ECG of the P-wave in NSR within 24 h of the procedure. Complex fractionated atrial electrograms areas accounted for 33 ± 24% of total LA. In NSR, only 12 ± 10% of LA area had LVE. There was no anatomic correlation between CFAE sites and LVE; the area of overlap between CFAE and LVE was only 1.6 ± 1.5%. Conduction velocity was faster in CFAE areas (2.3 ± 1.4 m/s) than in normal voltage areas (1.3 ± 0.3 m/s), and LVE areas (1.1 ± 0.7 m/s, P = 0.06). A positive correlation was only found between LVE areas and SAPW duration (r = 0.7, P = 0.04). CONCLUSION: Areas of CFAEs correspond to areas of normal atrial voltage and normal conduction velocity during NSR. Complex fractionated atrial electrogram probably represents the response of normal healthy atrial tissue to rapid pulmonary vein activation.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Sistema de Conducción Cardíaco/cirugía , Venas Pulmonares/cirugía , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Distribución de Chi-Cuadrado , Electrocardiografía , Femenino , Atrios Cardíacos/fisiopatología , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Venas Pulmonares/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
4.
Circ Arrhythm Electrophysiol ; 6(1): 151-9, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23255277

RESUMEN

BACKGROUND: Percutaneous left ventricular assist devices (pLVADs) are increasingly being used to facilitate ablation of unstable ventricular tachycardia (VT), but the safety profile and hemodynamic benefits of these devices have not been described in a systematic, prospective manner. METHODS AND RESULTS: Twenty patients with scar VT underwent ablation with a pLVAD. Neuromonitoring using cerebral oximetry was performed to evaluate a cerebral desaturation threshold to guide the duration of activation/entrainment mapping. The efficacy of pLVAD support was tested in a controlled manner with simulated VT. Complete procedural success was achieved in 50% (n=8) of patients, who were initially inducible for sustained VT, and partial procedural success in 37% (n=6). Using a cerebral desaturation level of 55% as a lower safety limit to guide the duration of sustained VT, 3 patients (15%) developed mild acute kidney injury (all resolved), and 1 (5%) patient developed mild cognitive dysfunction. During fast simulated VT (300 ms), cerebral desaturation to ≤55% occurred in more than half (53%) of patients tested without pLVAD support, compared with only 5% with full pLVAD support (P=0.003). CONCLUSIONS: In a consecutive series of patients with severe left ventricular dysfunction, pLVAD-supported scar VT ablation was safe and feasible. During fast simulated VT, a miniaturized axial flow pump imparted a more favorable hemodynamic profile compared with pharmacological agents alone. Cerebral oximetry is a complimentary monitoring modality during scar VT ablation, and avoidance of cerebral desaturations below a threshold of 55% may safely guide the duration of mapping during unstable VT.


Asunto(s)
Ablación por Catéter , Cicatriz/complicaciones , Corazón Auxiliar , Hemodinámica , Miocardio/patología , Taquicardia Ventricular/cirugía , Disfunción Ventricular Izquierda/terapia , Lesión Renal Aguda/etiología , Anciano , Presión Sanguínea , Ablación por Catéter/efectos adversos , Circulación Cerebrovascular , Cicatriz/patología , Trastornos del Conocimiento/etiología , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Intraoperatorio/métodos , Oximetría , Estudios Prospectivos , Diseño de Prótesis , Volumen Sistólico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/fisiopatología , Resultado del Tratamiento , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/fisiopatología , Función Ventricular Izquierda
5.
Europace ; 14(5): 653-60, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22417723

RESUMEN

AIMS: Temporary, ablation-mediated effects such as oedema may cause reversible pulmonary vein (PV) isolation. To investigate this, point-by-point circumferential ablation was performed to achieve acute electrical PV isolation with an incomplete circumferential ablation line. Then, the impact of this intentional 'visual gap' (ViG) on the conduction properties of the ablation lesion set was assessed with adenosine and pacing manoeuvres. METHODS AND RESULTS: Twenty-eight patients undergoing ablation for paroxysmal (n= 20) or persistent atrial fibrillation (n= 8) were included. Pulmonary vein (PV) ablation was performed around ipsilateral vein pairs. Once acute isolation was achieved, ablation was halted and the presence and size of the ViG were calculated. The ViG electrophysiological properties were tested with pace capture along the ViG at 10 mA/2 ms, and assessment for dormant PV conduction with adenosine. Despite electrical isolation, a ViG was present in 75% (n= 42/56) of vein pairs (21 of 28 left PVs and 21 of 28 right PVs). There was no difference in the ViG size between the left and right PVs (22.1 ± 14.2 and 17.3 ± 11.3 mm, P > 0.05). Dormant PV connections were revealed by adenosine in more than a quarter (n= 12/42) of acutely isolated PV pairs, of which the majority were dependent on conduction through the ViG. CONCLUSIONS: Electrical PV isolation can usually be achieved without complete circumferential ablation. However, more than a quarter of these 'isolated' PVs exhibit dormant conduction-predominantly via the un-ablated 'ViGs' in the ablation lesion set. These findings support the hypothesis that reversible tissue injury contributes to PV isolation that may be acute but not necessarily durable.


Asunto(s)
Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Complicaciones Posoperatorias/prevención & control , Venas Pulmonares/cirugía , Adenosina , Anciano , Antiarrítmicos , Fibrilación Atrial/complicaciones , Edema/complicaciones , Edema/fisiopatología , Femenino , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Periodo Intraoperatorio , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Valor Predictivo de las Pruebas , Venas Pulmonares/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA