Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
Intervalo de año de publicación
1.
Environ Pollut ; 272: 115992, 2021 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-33246769

RESUMEN

The unified bioaccessibility method (UBM) was harnessed to assess in vitro oral bioaccessibility pools of dialkyl phthalate congeners (with methyl, -ethyl, -butylbenzyl, -n-butyl, -2-ethylhexyl, and -n-octyl moieties) and bisphenol A at the 17 µg g-1 level in beach sand contaminated with polyethylene microplastics. A variety of sample preparation approaches prior to the analysis of the UBM gastrointestinal extracts, including traditional methods (protein precipitation, liquid-liquid extraction, and solid-phase extraction) and dispersive liquid-liquid microextraction (DLLME) were comprehensively evaluated for clean-up and analyte enrichment. DLLME was chosen among all tested approaches on account of the high extraction efficiency (73-95%, excluding bis(2-ethylhexyl)phthalate and di-n-octyl phthalate), high sample throughput (∼7 min per set of samples), and environmental friendliness as demonstrated by the analytical eco-scale score of 83, and the green analytical procedure index pictogram with green/yellow labeling. The release of the less hydrophobic plastic-laden compounds (dimethyl phthalate, diethyl phthalate and bisphenol A) from the contaminated sample into the body fluids was significant, with bioaccessibility values ranging from 30 to 70%, and from 43 to 74% in gastric and gastrointestinal fluids, respectively, and with relative standard deviation < 17% in all cases. The majority of the compounds were leached during gastric digestion, likely as the combined action of the low pH and the gastric enzymes. The risk exposure analysis revealed that accumulation/concentration in the body fluids is potentially relevant for dimethyl phthalate, diethyl phthalate and bisphenol A, with relative accumulation ratios ranging from 1.1 ± 0.1 to 2.6 ± 0.4. The average daily intake values for the suite of compounds, corrected with the bioaccessibility fraction, ranged from 60 to 430 ng kg of body weight-1·day-1, in all cases, far below the tolerable daily intakes, thus indicating the lack of children health risk by ingestion of microplastic-laden sand with elevated concentrations of plasticizers.


Asunto(s)
Disruptores Endocrinos , Ácidos Ftálicos , Niño , Humanos , Microplásticos , Extractos Vegetales , Plásticos , Arena
2.
Sci Total Environ ; 690: 217-225, 2019 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-31288113

RESUMEN

Soil pollution with trace elements is a concerning issue worldwide. Monitoring of soil pollution and remediation protocols need still from valid complementary analytical approaches able to detect changes in speciation and lability of metals in soils (e.g. stabilization or mobility). In this work, we compare three different analytical approaches to assess potential changes in environmental availability of Cu, As and Zn in a Mediterranean polluted soil that was amended with different combinations of iron sulphate and alkaline paper sludge waste. The studied methods were: (i) a standard large-bore flow-through column system (macrocolumn), (ii) an automatic dynamic flow-through microcolumn extraction system, and (iii) the diffusive gradients in thin gels technique (DGT). The three analytical approaches tested showed immobilization of Zn and Cu in contaminated mine soils after co-application of paper sludge and iron sulphate, but they differ quantitatively in terms of As mobility. Interconversion between oxidation states of inorganic As is observed to occur to a larger extent in macrocolumn. Because this may only occur in very specific Mediterranean scenarios (i.e. organic matter application to intermittently flooded mine soils), macrocolumn extraction procedures might not appropriately mimic the environmental availability of As in soils with organic amendments (e.g., paper sludge waste). Microcolumn leaching is the fastest screening tool to ascertain the efficiency of chemical amendments, but DGT is a good alternative with less technical demands.

3.
Anal Chem ; 91(1): 1140-1149, 2019 01 02.
Artículo en Inglés | MEDLINE | ID: mdl-30501183

RESUMEN

In this work, inexpensive manufacturing of unibody transparent mesofluidic platforms for pressure-driven Lab-On-a-Valve (LOV) methodologies is accomplished via rapid one-step 3D prototyping from digital models by user-friendly freeware. Multichannel architecture having 800-1800 µm cross-sectional features with unconventional 3D conduit structures and integrating optical and electrochemical detection facilities is for the first time reported. User-defined flow-programming capitalizing upon software control for automatic liquid handling is synergistically combined with additive manufacturing based on stereolithographic 3D printing so as to launch the so-called fourth generation of microflow analysis (3D-µFIA). Using an affordable consumer-grade 3D printer dedicated LOV platforms are 3D printed at will and prints are characterized in terms of solvent compatibility, optical and mechanical properties, and sorption of inorganic and organic species to prospect potentialities for the unfettered choice of chemistries. The unique versatility of the 3D-printed LOV device that is attached to a multiposition rotary valve as a central design unit is demonstrated by (i) online handling of biological materials followed by on-chip photometric detection, (ii) flow-through bioaccessibility tests in exposome studies of contaminated soils with miniaturized voltammetric detection, (iii) online phospholipid removal by TiO2-incorporated microextraction approaches using on-chip disposable sorbents, and (iv) automatic dynamic permeation tests mimicking transdermal measurements in Franz-cell configurations. A multipurpose LOV fluidic platform can be fabricated for less than 11 Euros.


Asunto(s)
Glucemia/análisis , Líquidos Corporales/química , Dispositivos Laboratorio en un Chip , Fosfolípidos/análisis , Impresión Tridimensional , Oligoelementos/análisis , Automatización , Bioensayo/instrumentación , Humanos
4.
Talanta ; 166: 391-398, 2017 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-28213251

RESUMEN

A novel fully automated in-vitro oral dissolution test assay as a front-end to liquid chromatography has been developed and validated for on-line chemical profiling and monitoring of temporal release profiles of three caffeoylquinic acid (CQA) isomers, namely, 3-CQA,4-CQA and 5-CQA, known as chlorogenic acids, in dietary supplements. Tangential-flow filtration is harnessed as a sample processing approach for on-line handling of CQA containing extracts of hard gelatin capsules and introduction of protein-free samples into the liquid chromatograph. Oral bioaccessibility/dissolution test assays were performed at 37.0±0.5°C as per US Pharmacopeia recommendations using pepsin with activity of ca. 749,000 USP units/L in 0.1mol/L HCl as the extraction medium and a paddle apparatus stirred at 50rpm. CQA release rates and steady-state dissolution conditions were determined accurately by fitting the chromatographic datasets, namely, the average cumulative concentrations of bioaccessible pools of every individual isomer monitored during 200min, with temporal resolutions of ≥10min, to a first-order dissolution kinetic model. Distinct solid-to-liquid phase ratios in the mimicry of physiological extraction conditions were assessed. Relative standard deviations for intra-day repeatability and inter-day intermediate precision of 5-CQA within the 5-40µg/mL concentration range were <3.4% and <5.5%, respectively. Trueness of the automatic flow method for determination of 5-CQA released from dietary supplements in gastric fluid surrogate was demonstrated by spike recoveries, spanning from 91.5-104.0%, upon completion of the dissolution process. The proposed hyphenated setup was resorted for evaluating potential differences in dissolution profiles and content of the three most abundant chlorogenic acid isomers in dietary supplements from varied manufacturers.


Asunto(s)
Ácido Clorogénico/farmacocinética , Cromatografía Liquida/métodos , Suplementos Dietéticos/análisis , Administración Oral , Disponibilidad Biológica , Ácido Clorogénico/administración & dosificación , Ácido Clorogénico/análisis , Café/química , Isomerismo , Límite de Detección , Sistemas en Línea
5.
Talanta ; 84(5): 1259-66, 2011 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-21641435

RESUMEN

In this work, a miniaturized, completely enclosed multisyringe-flow system is proposed for high-throughput purification of RuBisCO from Triticum aestivum extracts. The automated method capitalizes on the uptake of the target protein at 4°C onto Q-Sepharose Fast Flow strong anion-exchanger packed in a cylindrical microcolumn (105 × 4 mm) followed by a stepwise ionic-strength gradient elution (0-0.8 mol/L NaCl) to eliminate concomitant extract components and retrieve highly purified RuBisCO. The manifold is furnished downstream with a flow-through diode-array UV/vis spectrophotometer for real-time monitoring of the column effluent at the protein-specific wavelength of 280 nm to detect the elution of RuBisCO. Quantitation of RuBisCO and total soluble proteins in the eluate fractions were undertaken using polyacrylamide gel electrophoresis (PAGE) and the spectrophotometric Bradford assay, respectively. A comprehensive investigation of the effect of distinct concentration gradients on the isolation of RuBisCO and experimental conditions (namely, type of resin, column dimensions and mobile-phase flow rate) upon column capacity and analyte breakthrough was effected. The assembled set-up was aimed to critically ascertain the efficiency of preliminary batchwise pre-treatments of crude plant extracts (viz., polyethylenglycol (PEG) precipitation, ammonium sulphate precipitation and sucrose gradient centrifugation) in terms of RuBisCO purification and absolute recovery prior to automated anion-exchange column separation. Under the optimum physical and chemical conditions, the flow-through column system is able to admit crude plant extracts and gives rise to RuBisCO purification yields better than 75%, which might be increased up to 96 ± 9% with a prior PEG fractionation followed by sucrose gradient step.


Asunto(s)
Cromatografía por Intercambio Iónico/métodos , Análisis de Inyección de Flujo/métodos , Extractos Vegetales/química , Ribulosa-Bifosfato Carboxilasa/análisis , Ribulosa-Bifosfato Carboxilasa/aislamiento & purificación , Triticum/química , Automatización , Análisis de Inyección de Flujo/instrumentación , Concentración de Iones de Hidrógeno , Jeringas , Temperatura , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA