Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Pacing Clin Electrophysiol ; 45(9): 1042-1050, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35883271

RESUMEN

INTRODUCTION: Mitral valve surgery employing a superior transseptal approach (STA) is associated with arrhythmogenicity and intra-atrial conduction delay, despite being optimal for visualization of the surgical field. It is sometimes difficult to treat atrial tachycardias (AT) that arise after STA. To investigate AT circuits that arise after STA in detail in order to identify the optimal ablation line, using ultra-high-resolution mapping (UHRM). METHODS: We retrospectively analyzed 12 AT from 10 patients (median age 70 years, nine males) who had undergone STA surgery. The tachycardias were mapped using the Rhythmia mapping system (Boston Scientific, Natick, Massachusetts). RESULTS: The 12 STA-related AT (STA-AT) circuits were classifiable as follows according to location of the optimal ablation line: (1) peri-septal incision STA-AT (n = 3), (2) cavotricuspid isthmus (CTI) dependent STA-AT (n = 7), and (3) biatrial tachycardia (n = 2). Radiofrequency (RF) application terminated 11 of the 12 STA-AT. We found that difference in STA-AT circuit type was due to characteristics of the septal incision line made for STA. UHRM was important in identifying optimal ablation sites that did not create additional conduction disturbances in the right atrium (RA). CONCLUSIONS: ATs after STA involve complex arrhythmia circuits due to multiple and long incision lines in the RA. Accurate understanding of the arrhythmia circuit and sinus conduction in the RA after STA is recommended for treating post-surgical tachycardia in a minimally invasive manner.


Asunto(s)
Bloqueo Atrioventricular , Ablación por Catéter , Taquicardia Supraventricular , Anciano , Arritmias Cardíacas/cirugía , Bloqueo Atrioventricular/cirugía , Técnicas Electrofisiológicas Cardíacas , Humanos , Masculino , Válvula Mitral/cirugía , Estudios Retrospectivos , Taquicardia , Taquicardia Supraventricular/etiología , Taquicardia Supraventricular/prevención & control , Taquicardia Supraventricular/cirugía , Resultado del Tratamiento
2.
J Am Heart Assoc ; 11(13): e025697, 2022 07 05.
Artículo en Inglés | MEDLINE | ID: mdl-35766315

RESUMEN

Background The association between alcohol consumption, atrial substrate, and outcomes after atrial fibrillation (AF) ablation remains controversial. This study evaluated the impacts of drinking on left atrial substrate and AF recurrence after ablation. Methods and Results We prospectively enrolled 110 patients with AF without structural heart disease (64±12 years) from 2 institutions. High-density left atrial electroanatomic mapping was performed using a high-density grid multipolar catheter. We investigated the impact of alcohol consumption on left atrial voltage, left atrial conduction velocity, and AF ablation outcome. Patients were classified as abstainers (<1 drink/wk), mild drinkers (1-7 drinks/wk), or moderate-heavy drinkers (>7 drinks/wk). High-density mapping (mean 2287±600 points/patient) was performed on 49 abstainers, 27 mild drinkers, and 34 moderate-heavy drinkers. Low-voltage zone and slow-conduction zone were identified in 39 (35%) and 54 (49%) patients, respectively. There was no significant difference in the proportions of low-voltage zone and slow-conduction zone among the 3 groups. The success rate after a single ablation was significantly lower in drinkers than in abstainers (79.3% versus 95.9% at 12 months; mean follow-up, 18±8 months; P=0.013). The success rate after a single or multiple ablations was not significantly different among abstainers and drinkers. In multivariate analysis, alcohol consumption (P=0.02) and the presence of a low-voltage zone (P=0.032) and slow-conduction zone (P=0.02) were associated with AF recurrence after a single ablation, while low-voltage zone (P=0.023) and slow-conduction zone (P=0.024) were associated with AF recurrence after a single or multiple ablations. Conclusions Alcohol consumption was associated with AF recurrence after a single ablation but not changes in atrial substrate.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Consumo de Bebidas Alcohólicas/efectos adversos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Atrios Cardíacos , Humanos , Recurrencia , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA