Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
JACC Clin Electrophysiol ; 7(10): 1297-1308, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34217659

RESUMEN

OBJECTIVES: This study investigates the effect of stellate ganglion (SG) phototherapy in healthy participants and assesses its efficacy in suppressing electrical storm (ES) refractory to antiarrhythmic drugs and catheter ablation. BACKGROUND: Modulation of the autonomic nervous system has been shown to be an effective adjunctive therapy for ES. METHODS: Ten-minute SG phototherapy was performed twice weekly for 4 weeks in 20 healthy volunteers. To evaluate the acute and chronic effects of SG phototherapy, heart rate variability and serum concentrations of adrenaline, noradrenaline, and dopamine were obtained before phototherapy, immediately after the first phototherapy session, after 8 sessions of phototherapy, and 3 months after the first phototherapy session. In addition, the efficacy of SG phototherapy was evaluated in 11 patients with ES refractory to medication, sedation, and catheter ablation. RESULTS: In healthy participants, serum adrenaline concentration significantly decreased after phototherapy, whereas low-frequency power/high-frequency power significantly decreased during phototherapy. Moreover, the effect on heart rate variability did not last beyond 3 months. In the clinical pilot study, 7 patients had a suppression of ES after SG phototherapy; however, without maintenance therapy, 2 patients had a recurrence of ventricular arrhythmias. Furthermore, it did not control ES in 4 patients. CONCLUSIONS: SG phototherapy reduced sympathetic activity and may be a safe and effective adjunctive therapy to control ES in some patients, but its long-term efficacy remains unknown. Chronic phototherapy might help reduce ES recurrence.


Asunto(s)
Ganglio Estrellado , Taquicardia Ventricular , Arritmias Cardíacas , Humanos , Rayos Láser , Fototerapia , Proyectos Piloto
2.
J Cardiovasc Electrophysiol ; 31(2): 440-449, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31916643

RESUMEN

INTRODUCTION: The voltage map during sinus rhythm (SR) is a cornerstone of substrate mapping (SM) in scar-related ventricular tachycardia (VT) and frequently used with pace mapping (PM). Where to conduct PM is unclear in cases of an extensive or unidentified substrate. Conduction properties are another aspect incorporated by SM, and conduction slowing has gained interest as being related to successful ablation, although its mechanism has not been elucidated. We aimed to investigate the relationship between SR conduction properties and VT isthmuses. METHODS: Nineteen patients (mean age, 62 years) who underwent VT ablation with voltage mapping and PM were reviewed. Isochronal late activation maps (ILAMs) with eight zones were reconstructed and sequentially named from one to eight according to the SR propagation. Good PM sites were superimposed on ILAMs, and the isthmus was defined using different pacing latencies. ILAM properties harboring isthmuses were investigated. RESULTS: Twenty-eight ILAMs (13 epicardium, 1 right ventricular [RV], and 14 left ventricular [LV] endocardium) were reviewed. Eighteen isthmuses of 24 target VTs were identified, in which the proximal ends were in a later zone than the distal ends (zone 6 vs 4; P < .001), suggesting a reverse isthmus vector to the SR. The conduction velocity of the zone involving the distal isthmus was significantly lower than that of the SR preceding zone (0.40 vs 1.30 m/s; P < .001). SR conduction velocity decelerated by 69.5% (range 59.7%-74.5%) before propagating into the isthmus area. CONCLUSION: Conduction slowing area during SR were related with the exit portion of the VT isthmuses.


Asunto(s)
Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca , Taquicardia Ventricular/fisiopatología , Potenciales de Acción , Adulto , Anciano , Anciano de 80 o más Años , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Factores de Tiempo , Tokio
3.
Circ Arrhythm Electrophysiol ; 12(6): e007415, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-31113233

RESUMEN

Background His-bundle pacing (HBP) is a physiological form of pacing. Although high capture thresholds are common, few predictors of low HBP threshold have been determined. We aimed to identify electrophysiological predictors. Methods Fifty-one patients (53% with atrioventricular block) underwent HBP for bradycardia with an intrinsic QRS duration of <120 ms. Attempts to anchor the HBP lead were guided by unipolar His-bundle electrograms (HB EGMs) recorded with an electrophysiology recording system. Patients were followed-up for >6 months. Results In total, 153 attempts at anchoring the HBP lead were made, of which, 45 achieved acceptable HBP thresholds (≤2.5 V at 1 ms). The amplitude of negative deflection in HB EGM and the selective HBP form at fixation were independently associated with achieving an acceptable threshold. A negative amplitude of ≥0.060 mV in HB EGM was determined as the optimal value for identifying the acceptable threshold. This deep negative HB EGM was recorded with an HBP threshold of 1.4±1.3 V (in 34 attempts), significantly lower than that of positive HB EGM without deep negative deflection (2.8±1.3 V, in 31 trials; or >5 V, in 38 trials). The permanent HBP lead remained with deep negative (≥0.060 mV) or positive HB EGMs in 28 and 14 patients, respectively, and with positive or negative HB injury current in 19 and 23 patients, respectively. During follow-up, increased HBP threshold of >1 V was significantly more prevalent in the positive HB EGM group. The HBP thresholds of deep negative HB EGM and HB injury current, but not of the selective HBP group, were significantly lower than the other subgroups during follow-up. Conclusions Deep negative HB EGM at fixation was associated with an excellent short-term HBP threshold, similar to HB injury current. Analysis of unipolar HB EGM postfixation may enable prediction of permanent HBP threshold.


Asunto(s)
Potenciales de Acción , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/terapia , Bradicardia/diagnóstico , Fascículo Atrioventricular/fisiopatología , Estimulación Cardíaca Artificial , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Anciano , Anciano de 80 o más Años , Bloqueo Atrioventricular/fisiopatología , Bradicardia/fisiopatología , Bradicardia/terapia , Estimulación Cardíaca Artificial/efectos adversos , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Estudios Prospectivos , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
4.
Europace ; 21(7): 1039-1047, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-30891597

RESUMEN

AIMS: The circuit of pulmonary vein-gap re-entrant atrial tachycardia (PV-gap RAT) after atrial fibrillation ablation is sometimes difficult to identify by conventional mapping. We analysed the detailed circuit and electrophysiological features of PV-gap RATs using a novel high-resolution mapping system. METHODS AND RESULTS: This multicentre study investigated 27 (7%) PV-gap RATs in 26 patients among 378 atrial tachycardias (ATs) mapped with Rhythmia™ system in 281 patients. The tachycardia cycle length (TCL) was 258 ± 52 ms with P-wave duration of 116 ± 28 ms. Three types of PV-gap RAT circuits were identified: (A) two gaps in one pulmonary vein (PV) (unilateral circuit) (n = 17); (B) two gaps in the ipsilateral superior and inferior PVs (unilateral circuit) (n = 6); and (C) two gaps in one PV with a large circuit around contralateral PVs (bilateral circuit) (n = 4). Rhythmia™ mapping demonstrated two distinctive entrance and exit gaps of 7.6 ± 2.5 and 7.9 ± 4.1 mm in width, respectively, the local signals of which showed slow conduction (0.14 ± 0.18 and 0.11 ± 0.10m/s) with fragmentation (duration 86 ± 27 and 78 ± 23 ms) and low-voltage (0.17 ± 0.13 and 0.17 ± 0.21 mV). Twenty-two ATs were terminated (mechanical bump in one) and five were changed by the first radiofrequency application at the entrance or exit gap. Moreover, the conduction time inside the PVs (entrance-to-exit) was 138 ± 60 ms (54 ± 22% of TCL); in all cases, this resulted in demonstrating P-wave with an isoelectric line in all leads. CONCLUSION: This is the first report to demonstrate the detailed mechanisms of PV-gap re-entry that showed evident entrance and exit gaps using a high-resolution mapping system. The circuits were variable and Rhythmia™-guided ablation targeting the PV-gap can be curative.


Asunto(s)
Fibrilación Atrial/cirugía , Técnicas Electrofisiológicas Cardíacas , Complicaciones Posoperatorias/fisiopatología , Complicaciones Posoperatorias/cirugía , Venas Pulmonares/fisiopatología , Venas Pulmonares/cirugía , Taquicardia Supraventricular/fisiopatología , Taquicardia Supraventricular/cirugía , Ablación por Catéter/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
6.
Europace ; 16(7): 1007-14, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24446509

RESUMEN

AIMS: The step-wise approach to catheter ablation for persistent atrial fibrillation (AF) requires considerable substrate modification targeting at complex fractionated atrial electrograms (CFAEs) in addition to pulmonary vein (PV) isolation. An alternative strategy that minimizes the amount of ablation would be desirable. The aim of this study was to investigate whether the use of pre-procedural amiodarone affects: (i) the amount of ablation required to achieve procedural success, and (ii) long-term outcomes. METHODS AND RESULTS: We studied 121 consecutive patients with persistent AF who underwent catheter ablation. The patients were divided into two groups: Group 1, amiodarone (n = 31); Group 2, other antiarrhythmic drugs or rate control (n = 90). All the patients underwent a step-wise ablation procedure beginning with PV isolation, then proceeding with ablation of the CFAEs and linear lesions until sinus rhythm was achieved. Mean left atrial cycle length of AF (AFCL) was recorded at each step. The number of CFAE ablation sites was recorded. The number of CFAE sites in Group 1 was significantly less than that in Group 2 (P = 0.0121). The AFCLs after each step in Group 1 were significantly longer than those in Group 2. The procedure time and the radiofrequency time of CFAE ablation in Group 1 were significantly shorter than that in Group 2 (P = 0.0276 and P = 0.0458, respectively). There was no significant difference between the two groups in early and long-term outcomes. CONCLUSION: Use of pre-procedural amiodarone prolongs AFCL during catheter ablation and reduces the number of CFAE sites requiring ablation to achieve procedural success while maintaining equivalent long-term results.


Asunto(s)
Amiodarona/uso terapéutico , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/terapia , Ablación por Catéter , Tempo Operativo , Venas Pulmonares/efectos de los fármacos , Anciano , Amiodarona/efectos adversos , Antiarrítmicos/efectos adversos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Terapia Combinada , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/fisiopatología , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA