Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Cardiovasc Revasc Med ; 17(8): 566-570, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27641485

RESUMEN

BACKGROUND: Computed tomography (CT) has become the standard imaging modality for pre-procedural aortic annular sizing prior to transcatheter aortic valve replacement (TAVR). We hypothesized that the accuracy of CT derived annular measurements would be greater at sites with higher TAVR procedural volume. METHODS: Within a large integrated health system, TAVR was performed at low (<40 cases), intermediate (40-75 cases), and high-volume sites (>75 cases). 181 patients underwent TAVR with a Sapien XT transcatheter heart valve (THV). Two blinded experienced readers independently remeasured the annulus on CT and compared their measurements to site reported measurements. Hypothetical THV sizes were chosen based on measurements from site CT reports and independent readers' measurements, and compared to the implanted THV size. RESULTS: Correlation between site reported measurements and independent readers measurements of mean annulus size varied between low-volume (r=0.31, p=0.18), intermediate-volume (r=0.34, p=0.01), and high-volume sites (r=0.96, p<0.01). On multivariate analysis, interpretation of ≥20 CT scans (OR 0.29; 95% CI 0.03-0.81; p 0.02) and high-volume site (OR 0.16; 95% CI 0.10-0.82; p 0.02) were associated with reduced mismatch between the site predicted THV size and independent readers predicted THV size. Mismatch between site predicted THV size and implanted THV size was associated with a worse 30-day composite of mortality, dialysis-dependent renal failure, cerebrovascular accident, new permanent pacemaker, and hospital readmission (55.3 vs. 38.7%; p=0.05). CONCLUSIONS: Accuracy of CT aortic annular sizing is improved with higher individual experience and site TAVR volume. These findings should be confirmed in larger, prospective studies.


Asunto(s)
Válvula Aórtica/diagnóstico por imagen , Cateterismo Cardíaco/instrumentación , Angiografía por Tomografía Computarizada , Enfermedades de las Válvulas Cardíacas/terapia , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Hospitales de Alto Volumen , Hospitales de Bajo Volumen , Anciano , Anciano de 80 o más Años , Arizona , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/mortalidad , Competencia Clínica , Supervivencia sin Enfermedad , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Análisis Multivariante , Variaciones Dependientes del Observador , Oportunidad Relativa , Valor Predictivo de las Pruebas , Diseño de Prótesis , Interpretación de Imagen Radiográfica Asistida por Computador , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA