Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Ann Cardiol Angeiol (Paris) ; 70(5): 312-316, 2021 Nov.
Artículo en Francés | MEDLINE | ID: mdl-34548128

RESUMEN

This survey evaluated hypnosis practice in French centres in June 2020. The survey was sent via email to different rhythmology centres in France and responses from cardiologists and nurses were obtained. We present here the preliminary results of this survey. Hypnosis was used on a regular basis in 7.5% of the centres and 13% of the participants received education on hypnosis. 75% of the participants were interested to have an education of hypnosis. The survey points the different possibilities of improvement of management of patients while having the different procedures.


Asunto(s)
Hipnosis , Francia/epidemiología , Humanos , Encuestas y Cuestionarios
2.
J Interv Card Electrophysiol ; 60(2): 313-319, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32621214

RESUMEN

BACKGROUND: High-density automated mapping of complex atrial tachycardias (ATs) requires accurate assessment of activation maps. A new local activation display module (HD coloring, Biosense Webster®) provides higher map resolution, a better delineation of potential block reducing color interpolation, and a new propagation display. We evaluated the accuracy of a dedicated local activation display compared with standard algorithm. METHODS: High-density maps from 10 AT were collected with a multipolar catheter and were displayed with standard activation or HD coloring. Six expert operators retrospectively analyzed activation maps and were asked to define (1) the tachycardia mechanism, (2) ablation target, and (3) level of difficulty to interpret those maps. RESULTS: Using HD coloring, operators were able to reach a correct diagnosis in 93% vs. 63%, p < 0.05 compared to standard activation maps. Time to diagnosis was shorter 1.9 ± 1.0 min vs. 3.9 ± 2.1 min, p < 0.05. Confidence level would have allowed ablation without necessity for entrainment maneuvers in 87% vs. 53%, p < 0.05. Operators would have needed to remap or proceed with multiple entrainments in 3% vs. 13% of cases, p < 0.05. Finally, ablation strategy was more accurately identified in 97% vs. 67%, p < 0.05. CONCLUSION: Activation mapping with the new HD coloring module allowed a more accurate, reliable, and faster interpretation of complex ATs mechanisms compared to standard activation maps.


Asunto(s)
Ablación por Catéter , Taquicardia Supraventricular , Técnicas Electrofisiológicas Cardíacas , Humanos , Estudios Retrospectivos , Taquicardia , Taquicardia Supraventricular/diagnóstico por imagen , Taquicardia Supraventricular/cirugía
3.
J Interv Card Electrophysiol ; 38(3): 155-8, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24097226

RESUMEN

PURPOSE: Electrophysiological studies and radiofrequency catheter ablations require single or multiple sheath placements through femoral vein cannulation. The objective of this study was to determine the incidence, predictors, and outcomes of deep vein thrombosis (DVT) following such procedures. METHODS AND RESULTS: We prospectively enrolled 220 consecutive patients with a median age of 70 [60-79] years. The median duration of the procedures from insertion to removal of sheaths was 45 [30-75] min. At least two sheaths were inserted in 158 (72%) of the cases. Duplex ultrasonography evaluation of the lower leg veins was performed 6 h after the procedure and revealed common femoral vein thrombosis in 11 (5%) patients. All thrombi were partial and none was complete. Thrombi were mobile in four patients and extended to the external iliac vein in three patients. None of the patients presented with clinical signs of DVT or pulmonary embolism. Anticoagulation was prescribed for 2-4 weeks and a follow-up duplex ultrasonography obtained in the first seven patients revealed complete resolution of thrombi in all cases. On multivariate analysis, two predictors of thrombosis occurrence were identified: a greater sum of sheath diameters (odds ratio, 1.41 [95% confidence interval, 1.25-1.60] per 1-French increase; p < 0.001) and a longer procedural duration (odds ratio, 1.02 [95% confidence interval, 1.00-1.04] per 1-min increase; p = 0.04). CONCLUSIONS: Asymptomatic femoral DVT occur in 5% of electrophysiological studies and right-heart radiofrequency catheter ablations, particularly when large sheaths are inserted for a longer period. The role of anticoagulation in this clinical setting warrants further evaluation.


Asunto(s)
Ablación por Catéter/estadística & datos numéricos , Cateterismo/estadística & datos numéricos , Técnicas Electrofisiológicas Cardíacas/estadística & datos numéricos , Vena Femoral/diagnóstico por imagen , Trombosis de la Vena/diagnóstico por imagen , Trombosis de la Vena/epidemiología , Anciano , Causalidad , Femenino , Francia/epidemiología , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Factores de Riesgo , Ultrasonografía
4.
Arch Cardiovasc Dis ; 105(5): 281-90, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22709469

RESUMEN

BACKGROUND: Cardiac amyloidosis due to familial amyloid polyneuropathy (FAP) includes restrictive cardiomyopathy, thickened cardiac walls, conduction disorders and cardiac denervation. Impaired blood pressure variability has been documented in FAP related to the Val30Met mutation. AIMS: To document blood pressure variability in FAP patients with various mutation types and its relationship to the severity of cardiac involvement. METHODS: Blood pressure variability was analysed in 49 consecutive FAP patients and was compared with a matched control population. Cardiac evaluation included echocardiography, right heart catheterization, electrophysiological study, Holter electrocardiogram and metaiodobenzylguanidine (MIBG) scintigraphy. RESULTS: A non-dipping pattern was found in 80% of FAP patients and in 35% of control patients (P<0.0001); this was due to a significantly lower diurnal blood pressure in FAP patients (FAP group, 113 ± 21 mmHg; control group, 124 ± 8 mmHg; P<0.0001), whereas nocturnal blood pressures were similar. Among FAP patients, a non-dipping pattern was significantly associated with haemodynamic involvement, cardiac thickening or conduction disorders. These associations did not depend on the average blood pressure levels. Impaired blood pressure variability was more frequent and more pronounced in patients with multiple criteria for severe cardiac amyloidosis. CONCLUSION: Low blood pressure variability is common in cardiac amyloidosis due to FAP. A non-dipping pattern was more frequently observed in FAP patients with haemodynamic impairment, cardiac thickening or conduction disorders. It is suggested that impairment of circadian rhythm of blood pressure reflects the severity of cardiac amyloidosis due to FAP.


Asunto(s)
Neuropatías Amiloides Familiares/complicaciones , Presión Sanguínea , Cardiomiopatías/etiología , Ritmo Circadiano , 3-Yodobencilguanidina , Adulto , Anciano , Neuropatías Amiloides Familiares/genética , Neuropatías Amiloides Familiares/fisiopatología , Cateterismo Cardíaco , Cardiomiopatías/diagnóstico , Cardiomiopatías/fisiopatología , Estudios Transversales , Ecocardiografía , Electrocardiografía Ambulatoria , Técnicas Electrofisiológicas Cardíacas , Femenino , Francia , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Mutación , Prealbúmina/genética , Valor Predictivo de las Pruebas , Radiofármacos , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA