Lasers Surg Med ; 45(1): 28-33, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23280439

RESUMEN

BACKGROUND AND OBJECTIVE: Preclinical studies suggest an increased vaporization rate and speed of the 532 nm 180-W XPS GreenLight laser (180-W) compared with the 120-W HPS GreenLight laser (120-W) and the 80-W PV GreenLight laser (80-W). To test the clinical relevance of this observation we analyzed intraoperative data and early postoperative results after photoselective vaporization of the prostate (PVP) with the 180-W, 120-W, and 80-W laser. STUDY DESIGN/MATERIALS AND METHODS: A retrospective pair-to-pair comparison was performed including 80 consecutive patients who underwent PVP for the treatment of benign prostate enlargement with the 180-W, 120-W, and 80-W laser. The groups matched concerning age, prostate volume, PSA-value, and preoperative catheterization. Primary study outcome measurement was PSA-value reduction at 3 months; intraoperative data, perioperative complications, and early postoperative functional course were secondary study outcome measurements. RESULTS: Energy application per case (kJ), preoperative prostate volume (kJ/ml) operating time (kJ/minute), and lasing time (kJ/minute) was significantly higher with the 180-W laser. Prevalence of impaired visibility due to bleeding was comparable between the 180-W and the 120-W laser but significantly lower with 80-W. Duration of hospitalization was shorter with the 180-W laser compared to the former laser systems. During the postoperative course of 3 months voiding parameters and micturition symptoms significantly improved in all groups, the incidence of postoperative dysuria was comparable. Postoperative PSA-value reduction was significantly higher after treatment with the 180-W laser. CONCLUSIONS: With the 180-W laser, higher energy application and higher speed of tissue vaporization leads to increased tissue vaporization compared to the former 120-W and 80-W laser systems. Clinical efficacy and perioperative safety are maintained with the higher powered laser.


Asunto(s)
Láseres de Estado Sólido/uso terapéutico , Terapia por Luz de Baja Intensidad/instrumentación , Hiperplasia Prostática/terapia , Resección Transuretral de la Próstata/instrumentación , Anciano , Anciano de 80 o más Años , Hospitalización , Humanos , Terapia por Luz de Baja Intensidad/efectos adversos , Masculino , Hiperplasia Prostática/complicaciones , Hiperplasia Prostática/patología , Recuperación de la Función , Estudios Retrospectivos , Factores de Tiempo , Resección Transuretral de la Próstata/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA