Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Europace ; 20(suppl_2): ii11-ii21, 2018 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-29722861

RESUMEN

Aims: Remote magnetic navigation (RMN) is a safe and effective means of performing ventricular tachycardia (VT) ablation. It may have advantages over manual catheter ablation due to ease of manoeuvrability and catheter stability. We sought to compare the safety and efficacy of RMN vs. manual VT ablation. Methods and results: Retrospective study of procedural outcomes of 139 consecutive VT ablation procedures (69 RMN, 70 manual ablation) in 113 patients between 2009 and 2015 was performed. Remote magnetic navigation was associated with overall higher acute procedural success (80% vs. 60%, P = 0.01), with a trend to fewer major complications (3% vs. 9% P = 0.09). Seventy-nine patients were followed up for a median of 17.0 [interquartile range (IQR) 3.0-41.0] months for the RMN group and 15.5 (IQR 6.5-30.0) months for manual ablation group. In the ischaemic cardiomyopathy subgroup, RMN was associated with longer survival from the composite endpoint of VT recurrence leading to defibrillator shock, re-hospitalization or repeat catheter ablation and all-cause mortality; single-procedure adjusted hazard ratio (HR) 0.240 (95% CI 0.070-0.821) P = 0.023, multi-procedure HR 0.170 (95% CI 0.046-0.632) P = 0.002. In patients with implanted defibrillators, multi-procedure VT-free survival was superior with RMN, HR 0.199 (95% CI 0.060-0.657) P = 0.003. Conclusion: Remote magnetic navigation may improve clinical outcomes after catheter ablation of VT in patients with ischaemic cardiomyopathy. Further prospective clinical studies are required to confirm these findings.


Asunto(s)
Cateterismo Cardíaco/métodos , Ablación por Catéter/métodos , Magnetismo/métodos , Tecnología de Sensores Remotos/métodos , Cirugía Asistida por Computador/métodos , Taquicardia Ventricular/cirugía , Potenciales de Acción , Adulto , Anciano , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Catéteres Cardíacos , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Ablación por Catéter/mortalidad , Técnicas Electrofisiológicas Cardíacas , Femenino , Frecuencia Cardíaca , Humanos , Magnetismo/instrumentación , Imanes , Masculino , Persona de Mediana Edad , Recurrencia , Tecnología de Sensores Remotos/instrumentación , Estudios Retrospectivos , Factores de Riesgo , Cirugía Asistida por Computador/efectos adversos , Cirugía Asistida por Computador/instrumentación , Cirugía Asistida por Computador/mortalidad , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidad , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
2.
Artículo en Inglés | MEDLINE | ID: mdl-29038101

RESUMEN

BACKGROUND: Recent studies have demonstrated that intramyocardial adipose tissue (IMAT) may contribute to ventricular electrophysiological remodeling in patients with chronic myocardial infarction. Using an ovine model of myocardial infarction, we aimed to determine the influence of IMAT on scar tissue identification during endocardial contact mapping and optimal voltage-based mapping criteria for defining IMAT dense regions. METHOD AND RESULTS: In 7 sheep, left ventricular endocardial and transmural mapping was performed 84 weeks (15-111 weeks) post-myocardial infarction. Spearman rank correlation coefficient was used to assess the relationship between endocardial contact electrogram amplitude and histological composition of myocardium. Receiver operator characteristic curves were used to derive optimal electrogram thresholds for IMAT delineation during endocardial mapping and to describe the use of endocardial mapping for delineation of IMAT dense regions within scar. Endocardial electrogram amplitude correlated significantly with IMAT (unipolar r=-0.48±0.12, P<0.001; bipolar r=-0.45±0.22, P=0.04) but not collagen (unipolar r=-0.36±0.24, P=0.13; bipolar r=-0.43±0.31, P=0.16). IMAT dense regions of myocardium reliably identified using endocardial mapping with thresholds of <3.7 and <0.6 mV, respectively, for unipolar, bipolar, and combined modalities (single modality area under the curve=0.80, P<0.001; combined modality area under the curve=0.84, P<0.001). Unipolar mapping using optimal thresholding remained significantly reliable (area under the curve=0.76, P<0.001) during mapping of IMAT, confined to putative scar border zones (bipolar amplitude, 0.5-1.5 mV). CONCLUSIONS: These novel findings enhance our understanding of the confounding influence of IMAT on endocardial scar mapping. Combined bipolar and unipolar voltage mapping using optimal thresholds may be useful for delineating IMAT dense regions of myocardium, in postinfarct cardiomyopathy.


Asunto(s)
Tejido Adiposo/patología , Cicatriz/diagnóstico , Técnicas Electrofisiológicas Cardíacas , Endocardio/patología , Infarto del Miocardio/diagnóstico , Miocardio/patología , Potenciales de Acción , Animales , Área Bajo la Curva , Biopsia , Cicatriz/metabolismo , Cicatriz/patología , Cicatriz/fisiopatología , Colágeno/metabolismo , Modelos Animales de Enfermedad , Endocardio/metabolismo , Endocardio/fisiopatología , Frecuencia Cardíaca , Masculino , Infarto del Miocardio/metabolismo , Infarto del Miocardio/patología , Infarto del Miocardio/fisiopatología , Miocardio/metabolismo , Valor Predictivo de las Pruebas , Curva ROC , Reproducibilidad de los Resultados , Oveja Doméstica , Procesamiento de Señales Asistido por Computador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA