Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
JACC Clin Electrophysiol ; 10(4): 637-650, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38276927

RESUMEN

BACKGROUND: Voltage mapping to detect ventricular scar is important for guiding catheter ablation, but the field-of-view of unipolar, bipolar, conventional, and microelectrodes as it relates to the extent of viable myocardium (VM) is not well defined. OBJECTIVES: The purpose of this study was to evaluate electroanatomic voltage-mapping (EAVM) with different-size electrodes for identifying VM, validated against high-resolution ex-vivo cardiac magnetic resonance (HR-LGE-CMR). METHODS: A total of 9 swine with early-reperfusion myocardial infarction were mapped with the QDOT microcatheter. HR-LGE-CMR (0.3-mm slices) were merged with EAVM. At each EAVM point, the underlying VM in multisize transmural cylinders and spheres was quantified from ex vivo CMR and related to unipolar and bipolar voltages recorded from conventional and microelectrodes. RESULTS: In each swine, 220 mapping points (Q1, Q3: 216, 260 mapping points) were collected. Infarcts were heterogeneous and nontransmural. Unipolar and bipolar voltage increased with VM volumes from >175 mm3 up to >525 mm3 (equivalent to a 5-mm radius cylinder with height >6.69 mm). VM volumes in subendocardial cylinders with 1- or 3-mm depth correlated poorly with all voltages. Unipolar voltages recorded with conventional and microelectrodes were similar (difference 0.17 ± 2.66 mV) and correlated best to VM within a sphere of radius 10 and 8 mm, respectively. Distance-weighting did not improve the correlation. CONCLUSIONS: Voltage increases with transmural volume of VM but correlates poorly with small amounts of VM, which limits EAVM in defining heterogeneous scar. Microelectrodes cannot distinguish thin from thick areas of subendocardial VM. The field-of-view for unipolar recordings for microelectrodes and conventional electrodes appears to be 8 to 10 mm, respectively, and unexpectedly similar.


Asunto(s)
Infarto del Miocardio , Animales , Porcinos , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/fisiopatología , Imagen por Resonancia Magnética/métodos , Gadolinio , Técnicas Electrofisiológicas Cardíacas/instrumentación , Técnicas Electrofisiológicas Cardíacas/métodos , Microelectrodos , Electrodos , Miocardio/patología , Medios de Contraste
2.
JACC Clin Electrophysiol ; 5(10): 1130-1140, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31648737

RESUMEN

OBJECTIVES: This study sought to evaluate the value of combined electrogram (EGM) information provided by simultaneous mapping using micro- and conventional electrodes in the identification of post-myocardial infarction ventricular tachycardia substrate. BACKGROUND: Ventricular tachycardias after myocardial infarction are related to scars with complex geometry. Scar delineation and ventricular tachycardia substrate identification relies on bipolar voltages (BV) and EGM characteristics. Early reperfusion therapy results in small, nontransmural scars, the details of which may not be delineated using 3.5 mm tip catheters. METHODS: Nine swine with early reperfusion myocardial infarction were mapped using Biosense Webster's QDOT Micro catheter, incorporating 3 microelectrodes at the tip of the standard 3.5 mm electrode. Analysis of EGM during sinus rhythm, right ventricular pacing, and short-coupled right ventricular extrastimuli was performed. The swine were sacrificed and mapping data were projected onto the heart. Transmural biopsies (n = 196) corresponding to mapping points were obtained, allowing a head-to-head comparison of EGM recorded by micro- and conventional electrodes with histology. RESULTS: To identify scar areas using standard electrodes, unique cutoff values of unipolar voltage <5.44 mV, BV <1.27 mV (conventional), and BV <2.84 mV (microelectrode) were identified. Combining the information provided by unipolar voltage and BV mapping, the sensitivity of scar identification was increased to 93%. Micro-EGM were better able to distinguish small near-fields corresponding to a layer of viable subendocardium than conventional EGM were. CONCLUSIONS: The combined information provided by multisize electrode mapping increases the sensitivity with which areas of scar are identified. EGM from microelectrodes, with narrower spacing, allow identification of near-fields arising from thin subendocardial layer and layers activated with short delay obscured in EGM from conventional mapping catheter.


Asunto(s)
Cardiomiopatías/fisiopatología , Cicatriz/fisiopatología , Técnicas Electrofisiológicas Cardíacas/métodos , Isquemia Miocárdica/fisiopatología , Taquicardia Ventricular/fisiopatología , Animales , Cardiomiopatías/complicaciones , Cardiomiopatías/patología , Cicatriz/etiología , Cicatriz/patología , Electrodos , Endocardio/fisiopatología , Isquemia Miocárdica/complicaciones , Isquemia Miocárdica/patología , Porcinos , Taquicardia Ventricular/etiología
3.
Europace ; 21(12): 1919-1927, 2019 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-31545375

RESUMEN

AIMS: Contact force (CF) between radiofrequency (RF) ablation catheter and myocardium and ablation index (AI) correlates with RF lesion depth and width in normal-voltage (>1.5 mV) myocardium (NVM). We investigate the impact of CF on RF lesion depth and width in low (<0.5 mV) (LVM) and intermediate-voltage (0.5-1.5 mV) myocardium (IVM) following myocardial infarction. Correlation between RF lesion depth and width evaluated by native contrast magnetic resonance imaging (ncMRI) and gross anatomical evaluation was investigated. METHODS AND RESULTS: Twelve weeks after myocardial infarction, 10 pigs underwent electroanatomical mapping and endocardial RF ablations were deployed in NVM, IVM, and LVM myocardium. In vivo ncMRI was performed before the heart was excised and subjected to gross anatomical evaluation. Ninety (82%) RF lesions were evaluated. Radiofrequency lesion depth and width were smaller in IVM and LVM compared with NVM (P < 0.001). Radiofrequency lesion depth and width correlated with CF, AI, and impedance drop in NVM (CF and AI P < 0.001) and IVM (CF and AI depths P < 0.001; CF and AI widths P < 0.05). Native contrast magnetic resonance imaging evaluated RF lesion depth and width correlated with gross anatomical depth and width (NVM and IVM P < 0.001; LVM P < 0.05). CONCLUSIONS: Radiofrequency lesions deployed by similar duration, power and CF are smaller in IVM and LVM than in NVM. Radiofrequency lesion depth and width correlated with CF, AI, and impedance drop in NVM and IVM but not in LVM. Native contrast magnetic resonance imaging may be useful to assess RF lesion depth and width in NVM, IVM, and LVM.


Asunto(s)
Ablación por Catéter/métodos , Cicatriz/fisiopatología , Corazón/diagnóstico por imagen , Infarto del Miocardio/fisiopatología , Miocardio/patología , Taquicardia Ventricular/cirugía , Animales , Procedimientos Quirúrgicos Cardíacos , Cicatriz/diagnóstico por imagen , Cicatriz/patología , Impedancia Eléctrica , Técnicas Electrofisiológicas Cardíacas , Imagen por Resonancia Magnética , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/patología , Recurrencia , Sus scrofa , Porcinos , Taquicardia Ventricular/fisiopatología , Insuficiencia del Tratamiento
4.
Europace ; 20(3): 395-407, 2018 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-29300976

RESUMEN

There are major challenges ahead for clinicians treating patients with atrial fibrillation (AF). The population with AF is expected to expand considerably and yet, apart from anticoagulation, therapies used in AF have not been shown to consistently impact on mortality or reduce adverse cardiovascular events. New approaches to AF management, including the use of novel technologies and structured, integrated care, have the potential to enhance clinical phenotyping or result in better treatment selection and stratified therapy. Here, we report the outcomes of the 6th Consensus Conference of the Atrial Fibrillation Network (AFNET) and the European Heart Rhythm Association (EHRA), held at the European Society of Cardiology Heart House in Sophia Antipolis, France, 17-19 January 2017. Sixty-two global specialists in AF and 13 industry partners met to develop innovative solutions based on new approaches to screening and diagnosis, enhancing integration of AF care, developing clinical pathways for treating complex patients, improving stroke prevention strategies, and better patient selection for heart rate and rhythm control. Ultimately, these approaches can lead to better outcomes for patients with AF.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Cardiología/normas , Prestación Integrada de Atención de Salud/normas , Fibrilación Atrial/epidemiología , Fibrilación Atrial/fisiopatología , Consenso , Difusión de Innovaciones , Humanos , Valor Predictivo de las Pruebas , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA