Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37428890

RESUMEN

AIMS: Although the mechanism of an atrial tachycardia (AT) can usually be elucidated using modern high-resolution mapping systems, it would be helpful if the AT mechanism and circuit could be predicted before initiating mapping. OBJECTIVE: We examined if the information gathered from the cycle length (CL) of the tachycardia can help predict the AT-mechanism and its localization. METHODS: One hundred and thirty-eight activation maps of ATs including eight focal-ATs, 94 macroreentrant-ATs, and 36 localized-ATs in 95 patients were retrospectively reviewed. Maximal CL (MCL) and minimal CL (mCL) over a minute period were measured via a decapolar catheter in the coronary sinus. CL-variation and beat-by-beat CL-alternation were examined. Additionally, the CL-respiration correlation was analysed by the RhythmiaTM system. : Both MCL and mCL were significantly shorter in macroreentrant-ATs [MCL = 288 (253-348) ms, P = 0.0001; mCL = 283 (243-341) ms, P = 0.0012], and also shorter in localized-ATs [MCL = 314 (261-349) ms, P = 0.0016; mCL = 295 (248-340) ms, P = 0.0047] compared to focal-ATs [MCL = 506 (421-555) ms, mCL = 427 (347-508) ms]. An absolute CL-variation (MCL-mCL) < 24 ms significantly differentiated re-entrant ATs from focal-ATs with a sensitivity = 96.9%, specificity = 100%, positive predictive value (PPV) = 100%, and negative predictive value (NPV) = 66.7%. The beat-by-beat CL-alternation was observed in 10/138 (7.2%), all of which showed the re-entrant mechanism, meaning that beat-by-beat CL-alternation was the strong sign of re-entrant mechanism (PPV = 100%). Although the CL-respiration correlation was observed in 28/138 (20.3%) of ATs, this was predominantly in right-atrium (RA)-ATs (24/41, 85.7%), rather than left atrium (LA)-ATs (4/97, 4.1%). A positive CL-respiration correlation highly predicted RA-ATs (PPV = 85.7%), and negative CL-respiration correlation probably suggested LA-ATs (NPV = 84.5%). CONCLUSION: Detailed analysis of the tachycardia CL helps predict the AT-mechanism and the active AT chamber before an initial mapping.


Asunto(s)
Ablación por Catéter , Taquicardia Supraventricular , Humanos , Estudios Retrospectivos , Técnicas Electrofisiológicas Cardíacas , Taquicardia , Atrios Cardíacos , Resultado del Tratamiento
2.
Heart Rhythm ; 19(11): 1792-1801, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35961492

RESUMEN

BACKGROUND: Although differential pacing conventionally has been used to confirm the achievement of block across linear lesion sets, high-resolution mapping demonstrates that pseudo-block is observed in 20%-30% of cases. OBJECTIVES: The purpose of this study was to examine the reliability and versatility of a method using "activation vectors" based on omnipolar technology to confirm the block line. METHODS: Linear ablation was performed during pacing, with the HD Grid catheter (Abbott) placed beside the linear lesion opposite the pacing site. The endpoint of complete linear lesion was complete inversion of the activation vectors to the opposite direction. When inversion of the activation vectors was not observed after 10 minutes of radiofrequency (RF) application, high-resolution mapping was performed to assess whether complete block was achieved. RESULTS: In 33 patients, 24 cavotricuspid isthmus lines, 11 mitral isthmus (MI) lines, 16 posterior lines, and 2 intercaval lines were performed using this method. Of the total of 53 lines, 10 (18.9%) required intermediate evaluation of the block line with high-resolution mapping because of the absence of inversion of activation vectors despite 10 minutes of RF application, resulting in incomplete block with endocardial gaps or epicardial conductions. Additional RF applications finally achieved inversion in direction of activation vectors in the 10 lines. In total, the present method can diagnose achievement of complete block line with 100% accuracy, whereas conventional differential pacing misdiagnosed incomplete block with epicardial conduction in posterior lines in 3 cases and in MI lines in 2 cases. CONCLUSION: Confirmation of complete linear lesions using "activation vectors" based on omnipolar technology is a reliable and versatile method.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Humanos , Reproducibilidad de los Resultados , Resultado del Tratamiento , Ablación por Catéter/métodos , Frecuencia Cardíaca , Técnicas Electrofisiológicas Cardíacas , Aleteo Atrial/cirugía , Fibrilación Atrial/cirugía
3.
Heart Rhythm ; 17(8): 1271-1279, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32325198

RESUMEN

BACKGROUND: The mechanisms for scar-related ventricular tachycardia (VT) originating from the periaortic region remain incompletely characterized. OBJECTIVE: The purpose of this study was to map the circuits responsible for periaortic VT in high resolution. METHODS: Cases with periaortic VT (2016-2020) were analyzed to characterize the substrate and mechanisms with multielectrode mapping. Periaortic VT was defined as low-voltage and/or deceleration zones within 2 cm of the left ventriculoaortic junction with a corresponding critical site during VT. RESULTS: Forty-nine periaortic monomorphic VTs were analyzed in 30 patients (25% of all patients with nonischemic cardiomyopathy). Isolated periaortic substrate was observed in 27% of patients, with 73% having concomitant scar, most commonly in the mid-septum (47%). Deceleration zones were equally prevalent on the septal and lateral portions of the periaortic region (87% vs 73%; P = .19). During activation mapping of VT (tachycardia cycle length 392 ± 105 ms), localized reentrant patterns of activation (14 mm [10-17 mm] × 10 mm [7-14 mm]) were demonstrated in 63% and 37% of VTs showed centrifugal activation, consistent with a focal breakout pattern. Ninety-three percent of VTs fulfilled criteria for a reentrant mechanism. Sixty-five percent of reentrant circuits had endocardial activation gaps within the tachycardia cycle length (3-dimensional circuitry), which were associated with higher rates of recurrence as compared with 2-dimensional complete circuits at 1 year (73% vs 37%; P = .028). CONCLUSION: Periaortic VTs were observed in 25% of patients with nonischemic cardiomyopathy and scar-related VT. For the first time, localized reentry confined to this anatomically challenging region was demonstrated as the predominant mechanism by high-resolution circuit activation mapping.


Asunto(s)
Cicatriz/complicaciones , Sistema de Conducción Cardíaco/fisiopatología , Ventrículos Cardíacos/fisiopatología , Taquicardia Ventricular/fisiopatología , Anciano , Ablación por Catéter/métodos , Cicatriz/fisiopatología , Técnicas Electrofisiológicas Cardíacas , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía
4.
J Cardiovasc Electrophysiol ; 31(4): 968-971, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32077542

RESUMEN

We present a rare case of reentrant ventricular tachycardia proven by entrainment maneuvers that was successfully ablated from the noncoronary cusp. The case highlights regional anatomy, pacing maneuvers with multi-modality images from fluoroscopy, intracardiac echo, and electroanatomical mapping.


Asunto(s)
Bloqueo de Rama/cirugía , Ablación por Catéter , Taquicardia Ventricular/cirugía , Potenciales de Acción , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/fisiopatología , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
5.
Circulation ; 140(17): 1383-1397, 2019 10 22.
Artículo en Inglés | MEDLINE | ID: mdl-31533463

RESUMEN

BACKGROUND: Accurate and expedited identification of scar regions most prone to reentry is needed to guide ventricular tachycardia (VT) ablation. We aimed to prospectively assess outcomes of VT ablation guided primarily by the targeting of deceleration zones (DZ) identified by propagational analysis of ventricular activation during sinus rhythm. METHODS: Patients with scar-related VT were prospectively enrolled in the University of Chicago VT Ablation Registry between 2016 and 2018. Isochronal late activation maps annotated to the latest local electrogram deflection were created with high-density multielectrode mapping catheters. Targeted ablation of DZ (>3 isochrones within 1cm radius) was performed, prioritizing later activated regions with maximal isochronal crowding. When possible, activation mapping of VT was performed, and successful ablation sites were compared with DZ locations for mechanistic correlation. Patients were prospectively followed for VT recurrence and mortality. RESULTS: One hundred twenty patients (median age 65 years [59-71], 15% female, 50% nonischemic, median ejection fraction 31%) underwent 144 ablation procedures for scar-related VT. 57% of patients had previous ablation and epicardial access was employed in 59% of cases. High-density mapping during baseline rhythm was performed (2518 points [1615-3752] endocardial, 5049±2580 points epicardial) and identified an average of 2±1 DZ, which colocalized to successful termination sites in 95% of cases. The median total radiofrequency application duration was 29 min (21-38 min) to target DZ, representing ablation of 18% of the low-voltage area. At 12±10 months, 70% freedom from VT recurrence (80% in ischemic cardiomyopathy and 63% in nonischemic cardiomyopathy) was achieved. The overall survival rate was 87%. CONCLUSIONS: A novel voltage-independent high-density mapping display can identify the functional substrate for VT during sinus rhythm and guide targeted ablation, obviating the need for extensive radiofrequency delivery. Regions with isochronal crowding during the baseline rhythm were predictive of VT termination sites, providing mechanistic evidence that deceleration zones are highly arrhythmogenic, functioning as niduses for reentry.


Asunto(s)
Arritmias Cardíacas/fisiopatología , Mapeo del Potencial de Superficie Corporal , Cardiomiopatías/fisiopatología , Taquicardia Ventricular/fisiopatología , Anciano , Arritmias Cardíacas/terapia , Mapeo del Potencial de Superficie Corporal/métodos , Cardiomiopatías/terapia , Ablación por Catéter/métodos , Electrocardiografía/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Femenino , Frecuencia Cardíaca/fisiología , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/fisiopatología , Isquemia Miocárdica/terapia , Taquicardia Ventricular/terapia
7.
J Cardiovasc Electrophysiol ; 30(4): 528-537, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30656771

RESUMEN

INTRODUCTION: Adenosine triphosphate (ATP) sensitive atrial tachycardia (AT) has been treated by radiofrequency catheter ablation. Cryofreezing energy has emerged as a novel energy source for catheter ablation. The aim of this study was to investigate the efficacy and safety of cryofreezing ablation for ATP-sensitive AT. METHODS AND RESULTS: A total of six patients with ATP-sensitive ATs were included in this study. A single atrial extrastimulation was able to initiate and terminate these ATs in all six patients. The electrophysiological findings satisfied the diagnostic criteria of ATP-sensitive AT. The ablation catheter was located at the earliest activation site of atrial excitation during the AT, and cryofreezing energy was delivered through a cryoablation catheter to perform cryomapping at temperature of -30 or -80°C. When cryomapping successfully terminated the ATs, cryoablation at a temperature of -80°C was subsequently performed. The earliest atrial activation during AT was recorded at the Koch's triangle area associated with a distinct intra-atrial activation sequence from that recorded during ventricular pacing. Cryoablation was performed at successful cryomapping sites and resulted in the complete elimination of the AT in all six patients without affecting the bidirectional atrioventricular (AV) nodal conduction. CONCLUSION: Cryofreezing energy was safe and effective in treating ATP-sensitive ATs even in patients with its origins located in the vicinity of the AV node.


Asunto(s)
Adenosina Trifosfato/administración & dosificación , Criocirugía , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Taquicardia Supraventricular/cirugía , Potenciales de Acción , Adulto , Anciano , Criocirugía/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA