Europace ; 25(2): 469-477, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36369980

RESUMEN

AIMS: Existing strategies that identify post-infarct ventricular tachycardia (VT) ablation target either employ invasive electrophysiological (EP) mapping or non-invasive modalities utilizing the electrocardiogram (ECG). Their success relies on localizing sites critical to the maintenance of the clinical arrhythmia, not always recorded on the 12-lead ECG. Targeting the clinical VT by utilizing electrograms (EGM) recordings stored in implanted devices may aid ablation planning, enhancing safety and speed and potentially reducing the need of VT induction. In this context, we aim to develop a non-invasive computational-deep learning (DL) platform to localize VT exit sites from surface ECGs and implanted device intracardiac EGMs. METHODS AND RESULTS: A library of ECGs and EGMs from simulated paced beats and representative post-infarct VTs was generated across five torso models. Traces were used to train DL algorithms to localize VT sites of earliest systolic activation; first tested on simulated data and then on a clinically induced VT to show applicability of our platform in clinical settings. Localization performance was estimated via localization errors (LEs) against known VT exit sites from simulations or clinical ablation targets. Surface ECGs successfully localized post-infarct VTs from simulated data with mean LE = 9.61 ± 2.61 mm across torsos. VT localization was successfully achieved from implanted device intracardiac EGMs with mean LE = 13.10 ± 2.36 mm. Finally, the clinically induced VT localization was in agreement with the clinical ablation volume. CONCLUSION: The proposed framework may be utilized for direct localization of post-infarct VTs from surface ECGs and/or implanted device EGMs, or in conjunction with efficient, patient-specific modelling, enhancing safety and speed of ablation planning.


Asunto(s)
Ablación por Catéter , Aprendizaje Profundo , Taquicardia Ventricular , Humanos , Técnicas Electrofisiológicas Cardíacas , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía , Electrocardiografía/métodos , Infarto/cirugía
2.
Med Image Anal ; 61: 101626, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32000114

RESUMEN

Patient-specific computational models of structure and function are increasingly being used to diagnose disease and predict how a patient will respond to therapy. Models of anatomy are often derived after segmentation of clinical images or from mapping systems which are affected by image artefacts, resolution and contrast. Quantifying the impact of uncertain anatomy on model predictions is important, as models are increasingly used in clinical practice where decisions need to be made regardless of image quality. We use a Bayesian probabilistic approach to estimate the anatomy and to quantify the uncertainty about the shape of the left atrium derived from Cardiac Magnetic Resonance images. We show that we can quantify uncertain shape, encode uncertainty about the left atrial shape due to imaging artefacts, and quantify the effect of uncertain shape on simulations of left atrial activation times.


Asunto(s)
Atrios Cardíacos/anatomía & histología , Imagen por Resonancia Magnética , Modelos Cardiovasculares , Artefactos , Teorema de Bayes , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos/diagnóstico por imagen , Humanos , Análisis de Componente Principal , Incertidumbre
3.
Clin Med (Lond) ; 20(1): 43-47, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31941731

RESUMEN

Supraventricular tachycardia (SVT) is a common cause of hospital admissions and can cause significant patient discomfort and distress. The most common SVTs include atrioventricular nodal re-entrant tachycardia, atrioventricular re-entrant tachycardia and atrial tachycardia. In many cases, the underlying mechanism can be deduced from electrocardiography during tachycardia, comparing it with sinus rhythm, and assessing the onset and offset of tachycardia. Recent European Society of Cardiology guidelines continue to advocate the use of vagal manoeuvres and adenosine as first-line therapies in the acute diagnosis and management of SVT. Alternative therapies include the use of beta-blockers and calcium channel blockers. All patients treated for SVT should be referred for a heart rhythm specialist opinion. Long-term treatment is dependent on several factors including frequency of symptoms, risk stratification, and patient preference. Management can range from conservative, if symptoms are rare and the patient is low risk, to catheter ablation which is curative in the majority of patients.


Asunto(s)
Ablación por Catéter , Taquicardia Supraventricular , Adenosina , Antagonistas Adrenérgicos beta , Electrocardiografía , Humanos , Taquicardia Supraventricular/cirugía , Taquicardia Supraventricular/terapia
4.
IEEE Trans Biomed Eng ; 67(1): 99-109, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-30969911

RESUMEN

OBJECTIVE: Local activation time (LAT) mapping of the atria is important for targeted treatment of atrial arrhythmias, but current methods do not interpolate on the atrial manifold and neglect uncertainties associated with LAT observations. In this paper, we describe novel methods to, first, quantify uncertainties in LAT arising from bipolar electrogram analysis and assignment of electrode recordings to the anatomical mesh, second, interpolate uncertain LAT measurements directly on left atrial manifolds to obtain complete probabilistic activation maps, and finally, interpolate LAT jointly across both the manifold and different S1-S2 pacing protocols. METHODS: A modified center of mass approach was used to process bipolar electrograms, yielding a LAT estimate and error distribution from the electrogram morphology. An error distribution for assigning measurements to the anatomical mesh was estimated. Probabilistic LAT maps were produced by interpolating on a left atrial manifold using Gaussian Markov random fields, taking into account observation errors and characterizing LAT predictions by their mean and standard deviation. This approach was extended to interpolate across S1-S2 pacing protocols. RESULTS: We evaluated our approach using recordings from three patients undergoing atrial ablation. Cross-validation showed consistent and accurate prediction of LAT observations both at different locations on the left atrium and for different S1-S2 intervals. SIGNIFICANCE: Interpolation of scalar and vector fields across anatomical structures from point measurements is a challenging problem in biomedical engineering, compounded by uncertainties in measurements and meshes. New methods and approaches are required, and in this paper, we have demonstrated an effective method for probabilistic interpolation of uncertain LAT.


Asunto(s)
Función Atrial/fisiología , Técnicas Electrofisiológicas Cardíacas/métodos , Atrios Cardíacos/diagnóstico por imagen , Modelos Estadísticos , Procesamiento de Señales Asistido por Computador , Humanos
5.
Europace ; 21(9): 1432-1441, 2019 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-31219547

RESUMEN

AIMS: Potential advantages of real-time magnetic resonance imaging (MRI)-guided electrophysiology (MR-EP) include contemporaneous three-dimensional substrate assessment at the time of intervention, improved procedural guidance, and ablation lesion assessment. We evaluated a novel real-time MR-EP system to perform endocardial voltage mapping and assessment of delayed conduction in a porcine ischaemia-reperfusion model. METHODS AND RESULTS: Sites of low voltage and slow conduction identified using the system were registered and compared to regions of late gadolinium enhancement (LGE) on MRI. The Sorensen-Dice similarity coefficient (DSC) between LGE scar maps and voltage maps was computed on a nodal basis. A total of 445 electrograms were recorded in sinus rhythm (range: 30-186) using the MR-EP system including 138 electrograms from LGE regions. Pacing captured at 103 sites; 47 (45.6%) sites had a stimulus-to-QRS (S-QRS) delay of ≥40 ms. Using conventional (0.5-1.5 mV) bipolar voltage thresholds, the sensitivity and specificity of voltage mapping using the MR-EP system to identify MR-derived LGE was 57% and 96%, respectively. Voltage mapping had a better predictive ability in detecting LGE compared to S-QRS measurements using this system (area under curve: 0.907 vs. 0.840). Using an electrical threshold of 1.5 mV to define abnormal myocardium, the total DSC, scar DSC, and normal myocardium DSC between voltage maps and LGE scar maps was 79.0 ± 6.0%, 35.0 ± 10.1%, and 90.4 ± 8.6%, respectively. CONCLUSION: Low-voltage zones and regions of delayed conduction determined using a real-time MR-EP system are moderately associated with LGE areas identified on MRI.


Asunto(s)
Trastorno del Sistema de Conducción Cardíaco/diagnóstico por imagen , Trastorno del Sistema de Conducción Cardíaco/fisiopatología , Técnicas Electrofisiológicas Cardíacas/métodos , Imagen por Resonancia Magnética Intervencional/métodos , Daño por Reperfusión Miocárdica/fisiopatología , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/fisiopatología , Animales , Trastorno del Sistema de Conducción Cardíaco/etiología , Trastorno del Sistema de Conducción Cardíaco/cirugía , Ablación por Catéter , Modelos Animales de Enfermedad , Imagen por Resonancia Magnética/métodos , Masculino , Daño por Reperfusión Miocárdica/complicaciones , Daño por Reperfusión Miocárdica/diagnóstico por imagen , Cirugía Asistida por Computador , Sus scrofa , Porcinos , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía
6.
Europace ; 20(12): 2028-2035, 2018 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-29701778

RESUMEN

Aims: Conducting gaps in lesion sets are a major reason for failure of ablation procedures. Voltage mapping and pace-capture have been proposed for intra-procedural identification of gaps. We aimed to compare gap size measured acutely and chronically post-ablation to macroscopic gap size in a porcine model. Methods and results: Intercaval linear ablation was performed in eight Göttingen minipigs with a deliberate gap of ∼5 mm left in the ablation line. Gap size was measured by interpolating ablation contact force values between ablation tags and thresholding at a low force cut-off of 5 g. Bipolar voltage mapping and pace-capture mapping along the length of the line were performed immediately, and at 2 months, post-ablation. Animals were euthanized and gap sizes were measured macroscopically. Voltage thresholds to define scar were determined by receiver operating characteristic analysis as <0.56 mV (acutely) and <0.62 mV (chronically). Taking the macroscopic gap size as gold standard, error in gap measurements were determined for voltage, pace-capture, and ablation contact force maps. All modalities overestimated chronic gap size, by 1.4 ± 2.0 mm (ablation contact force map), 5.1 ± 3.4 mm (pace-capture), and 9.5 ± 3.8 mm (voltage mapping). Error on ablation contact force map gap measurements were significantly less than for voltage mapping (P = 0.003, Tukey's multiple comparisons test). Chronically, voltage mapping and pace-capture mapping overestimated macroscopic gap size by 11.9 ± 3.7 and 9.8 ± 3.5 mm, respectively. Conclusion: Bipolar voltage and pace-capture mapping overestimate the size of chronic gap formation in linear ablation lesions. The most accurate estimation of chronic gap size was achieved by analysis of catheter-myocardium contact force during ablation.


Asunto(s)
Potenciales de Acción , Ablación por Catéter/efectos adversos , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos/cirugía , Frecuencia Cardíaca , Animales , Atrios Cardíacos/patología , Atrios Cardíacos/fisiopatología , Modelos Animales , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Porcinos , Porcinos Enanos , Insuficiencia del Tratamiento
8.
Europace ; 20(FI2): f254-f262, 2018 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-29294008

RESUMEN

Aims: Magnetic resonance imaging (MRI) is the gold standard for defining myocardial substrate in 3D and can be used to guide ventricular tachycardia ablation. We describe the feasibility of using a prototype magnetic resonance-guided electrophysiology (MR-EP) system in a pre-clinical model to perform real-time MRI-guided epicardial mapping, ablation, and lesion imaging with active catheter tracking. Methods and results: Experiments were performed in vivo in pigs (n = 6) using an MR-EP guidance system research prototype (Siemens Healthcare) with an irrigated ablation catheter (Vision-MR, Imricor) and a dedicated electrophysiology recording system (Advantage-MR, Imricor). Following epicardial access, local activation and voltage maps were acquired, and targeted radiofrequency (RF) ablation lesions were delivered. Ablation lesions were visualized in real time during RF delivery using MR-thermometry and dosimetry. Hyper-acute and acute assessment of ablation lesions was also performed using native T1 mapping and late-gadolinium enhancement (LGE), respectively. High-quality epicardial bipolar electrograms were recorded with a signal-to-noise ratio of greater than 10:1 for a signal of 1.5 mV. During epicardial ablation, localized temperature elevation could be visualized with a maximum temperature rise of 35 °C within 2 mm of the catheter tip relative to remote myocardium. Decreased native T1 times were observed (882 ± 107 ms) in the lesion core 3-5 min after lesion delivery and relative location of lesions matched well to LGE. There was a good correlation between ablation lesion site on the iCMR platform and autopsy. Conclusion: The MR-EP system was able to successfully acquire epicardial voltage and activation maps in swine, deliver, and visualize ablation lesions, demonstrating feasibility for intraprocedural guidance and real-time assessment of ablation injury.


Asunto(s)
Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Ventrículos Cardíacos/cirugía , Imagen por Resonancia Magnética Intervencional , Potenciales de Acción , Animales , Catéteres Cardíacos , Ablación por Catéter/instrumentación , Medios de Contraste/administración & dosificación , Técnicas Electrofisiológicas Cardíacas/instrumentación , Estudios de Factibilidad , Femenino , Gadolinio DTPA/administración & dosificación , Frecuencia Cardíaca , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/patología , Ventrículos Cardíacos/fisiopatología , Modelos Animales , Valor Predictivo de las Pruebas , Sus scrofa , Factores de Tiempo
9.
Europace ; 20(2): e11-e20, 2018 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-28379525

RESUMEN

Aims: Local activation time (LAT) mapping forms the cornerstone of atrial tachycardia diagnosis. Although anatomic and positional accuracy of electroanatomic mapping (EAM) systems have been validated, the effect of electrode sampling density on LAT map reconstruction is not known. Here, we study the effect of chamber geometry and activation complexity on optimal LAT sampling density using a combined in silico and in vivo approach. Methods and results: In vivo 21 atrial tachycardia maps were studied in three groups: (1) focal activation, (2) macro-re-entry, and (3) localized re-entry. In silico activation was simulated on a 4×4cm atrial monolayer, sampled randomly at 0.25-10 points/cm2 and used to re-interpolate LAT maps. Activation patterns were studied in the geometrically simple porcine right atrium (RA) and complex human left atrium (LA). Activation complexity was introduced into the porcine RA by incomplete inter-caval linear ablation. In all cases, optimal sampling density was defined as the highest density resulting in minimal further error reduction in the re-interpolated maps. Optimal sampling densities for LA tachycardias were 0.67 ± 0.17 points/cm2 (focal activation), 1.05 ± 0.32 points/cm2 (macro-re-entry) and 1.23 ± 0.26 points/cm2 (localized re-entry), P = 0.0031. Increasing activation complexity was associated with increased optimal sampling density both in silico (focal activation 1.09 ± 0.14 points/cm2; re-entry 1.44 ± 0.49 points/cm2; spiral-wave 1.50 ± 0.34 points/cm2, P < 0.0001) and in vivo (porcine RA pre-ablation 0.45 ± 0.13 vs. post-ablation 0.78 ± 0.17 points/cm2, P = 0.0008). Increasing chamber geometry was also associated with increased optimal sampling density (0.61 ± 0.22 points/cm2 vs. 1.0 ± 0.34 points/cm2, P = 0.0015). Conclusion: Optimal sampling densities can be identified to maximize diagnostic yield of LAT maps. Greater sampling density is required to correctly reveal complex activation and represent activation across complex geometries. Overall, the optimal sampling density for LAT map interpolation defined in this study was ∼1.0-1.5 points/cm2.


Asunto(s)
Función Atrial , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos/fisiopatología , Taquicardia Supraventricular/diagnóstico , Potenciales de Acción , Animales , Estimulación Cardíaca Artificial , Simulación por Computador , Modelos Animales de Enfermedad , Frecuencia Cardíaca , Humanos , Modelos Cardiovasculares , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Porcinos , Porcinos Enanos , Taquicardia Supraventricular/fisiopatología , Factores de Tiempo
10.
JACC Clin Electrophysiol ; 3(2): 89-103, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-29759398

RESUMEN

OBJECTIVES: This study sought to develop an actively tracked cardiac magnetic resonance-guided electrophysiology (CMR-EP) system and perform first-in-human clinical ablation procedures. BACKGROUND: CMR-EP offers high-resolution anatomy, arrhythmia substrate, and ablation lesion visualization in the absence of ionizing radiation. Implementation of active tracking, where catheter position is continuously transmitted in a manner analogous to electroanatomic mapping (EAM), is crucial for CMR-EP to take the step from theoretical technology to practical clinical tool. METHODS: The setup integrated a clinical 1.5-T scanner, an EP recording and ablation system, and a real-time image guidance platform with components undergoing ex vivo validation. The full system was assessed using a preclinical study (5 pigs), including mapping and ablation with histological validation. For the clinical study, 10 human subjects with typical atrial flutter (age 62 ± 15 years) underwent MR-guided cavotricuspid isthmus (CTI) ablation. RESULTS: The components of the CMR-EP system were safe (magnetically induced torque, radiofrequency heating) and effective in the CMR environment (location precision). Targeted radiofrequency ablation was performed in all animals and 9 (90%) humans. Seven patients had CTI ablation completed using CMR guidance alone; 2 patients required completion under fluoroscopy, with 2 late flutter recurrences. Acute and chronic CMR imaging demonstrated efficacious lesion formation, verified with histology in animals. Anatomic shape of the CTI was an independent predictor of procedural success. CONCLUSIONS: CMR-EP using active catheter tracking is safe and feasible. The CMR-EP setup provides an effective workflow and has the potential to change the way in which ablation procedures may be performed.


Asunto(s)
Aleteo Atrial/patología , Aleteo Atrial/cirugía , Ablación por Catéter/métodos , Angiografía por Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Animales , Cicatriz/patología , Técnicas Electrofisiológicas Cardíacas/métodos , Estudios de Factibilidad , Femenino , Humanos , Imagen por Resonancia Cinemagnética/métodos , Imagen por Resonancia Magnética Intervencional/métodos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Cirugía Asistida por Computador/métodos , Sus scrofa , Porcinos , Resultado del Tratamiento , Adulto Joven
11.
Europace ; 19(10): 1743-1749, 2017 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-27702855

RESUMEN

AIMS: Complex ablation procedures are supported by accurate representation of an increasing variety of electrophysiological and imaging data within electroanatomic mapping systems (EMS). This study aims to develop a novel method for representing multiple complementary datasets on a single cardiac chamber model. Validation of the system and its application to both atrial and ventricular arrhythmias is examined. METHODS AND RESULTS: Dot mapping was conceived to display multiple datasets by utilizing quantitative surface shading to represent one dataset and finely spaced dots to represent others. Dot positions are randomized within triangular (surface meshes) or tetrahedral (volumetric meshes) simplices making the approach directly transferrable to contemporary EMS. Test data representing uniform electrical activation (n = 10) and focal scarring (n = 10) were used to test dot mapping data perception accuracy. User experience of dot mapping with atrial and ventricular clinical data is evaluated. Dot mapping ensured constant screen dot density for regions of uniform dataset values, regardless of user manipulation of the cardiac chamber. Perception accuracy of dot mapping was equivalent to colour mapping for both propagation direction (1.5 ± 1.8 vs. 4.8 ± 5.3°, P = 0.24) and focal source localization (1.1 ± 0.7 vs. 1.4 ± 0.5 mm, P = 0.88). User acceptance testing revealed equivalent diagnostic accuracy and display fidelity when compared with colour mapping. CONCLUSION: Dot mapping provides the unique ability to display multiple datasets from multiple sources on a single cardiac chamber model. The visual combination of multiple datasets may facilitate interpretation of complex electrophysiological and imaging data.


Asunto(s)
Potenciales de Acción , Arritmias Cardíacas/diagnóstico , Gráficos por Computador , Técnicas Electrofisiológicas Cardíacas , Sistema de Conducción Cardíaco/fisiopatología , Imagenología Tridimensional , Procesamiento de Señales Asistido por Computador , Algoritmos , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/terapia , Sistema de Conducción Cardíaco/diagnóstico por imagen , Frecuencia Cardíaca , Humanos , Imagen por Resonancia Magnética , Modelos Cardiovasculares , Modelación Específica para el Paciente , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Factores de Tiempo
13.
Circ Arrhythm Electrophysiol ; 8(1): 18-24, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25528745

RESUMEN

BACKGROUND: This study aimed to determine 5-year efficacy of catheter ablation for persistent atrial fibrillation (AF) using AF termination as a procedural end point. METHODS AND RESULTS: One hundred fifty patients (57±10 years) underwent persistent AF ablation using a stepwise ablation approach (pulmonary vein isolation, electrogram-guided, and linear ablation) with the desired procedural end point being AF termination. Repeat ablation was performed for recurrent AF or atrial tachycardia. AF was terminated by ablation in 120 patients (80%). Arrhythmia-free survival rates after a single procedure were 35.3%±3.9%, 28.0%±3.7%, and 16.8%±3.2% at 1, 2, and 5 years, respectively. Arrhythmia-free survival rates after the last procedure (mean 2.1±1.0 procedures) were 89.7%±2.5%, 79.8%±3.4%, and 62.9%±4.5%, at 1, 2, and 5 years, respectively. During a median follow-up of 58 (interquartile range, 43-73) months after the last ablation procedure, 97 of 150 (64.7%) patients remained in sinus rhythm without antiarrhythmic drugs. Another 14 (9.3%) patients maintained sinus rhythm after reinitiation of antiarrhythmic drugs, and an additional 15 (10.0%) patients regressed to paroxysmal recurrences only. Failure to terminate AF during the index procedure (hazard ratio 3.831; 95% confidence interval, 2.070-7.143; P<0.001), left atrial diameter≥50 mm (hazard ratio 2.083; 95% confidence interval, 1.078-4.016; P=0.03), continuous AF duration≥18 months (hazard ratio 1.984; 95% confidence interval, 1.024-3.846; P<0.04), and structural heart disease (hazard ratio 1.874; 95% confidence interval, 1.037-3.388; P=0.04) predicted arrhythmia recurrence. CONCLUSIONS: In patients with persistent AF, an ablation strategy aiming at AF termination is associated with freedom from arrhythmia recurrence in the majority of patients over a 5-year follow-up period. Procedural AF nontermination and specific baseline factors predict long-term outcome after ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Venas Pulmonares/cirugía , Anciano , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Supervivencia sin Enfermedad , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Recurrencia , Reoperación , Factores de Riesgo , Taquicardia Supraventricular/etiología , Taquicardia Supraventricular/cirugía , Factores de Tiempo , Resultado del Tratamiento
14.
Arch Cardiovasc Dis ; 106(10): 501-10, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24070597

RESUMEN

BACKGROUND: The classification of atrial fibrillation as paroxysmal or persistent (PsAF) is clinically useful, but does not accurately reflect the underlying pathophysiology and is therefore a suboptimal guide to selection of ablation strategy. AIM: To determine if additional substrate ablation is beneficial for a subset of patients with PsAF, in whom long periods of sinus rhythm (SR) can be maintained. METHODS: We included patients presenting with PsAF in whom continuous periods of SR>3months were documented. All patients were in SR on the day of the procedure. Electrical pulmonary vein isolation (PVI) was performed in all patients. Additional electrogram (EGM)-guided ablation was left to the discretion of the operator. Patient characteristics and follow-up were analysed with respect to presence or absence of additional EGM-guided ablation. RESULTS: Sixty-five patients (mean age 60.1±8.9years; 81.5% men) met the inclusion criteria. EGM-guided ablation was performed in 32 (49%) patients. Patients with and without EGM-guided ablation had similar baseline characteristics. Absence of EGM-guided ablation was one of the independent predictors for arrhythmia recurrences after the index procedure (hazard ratio 0.24; confidence interval 0.12-0.47). After a median follow-up of 18±10months, the number of procedures required was significantly higher in the 'PVI-only' group (2.24±0.75 vs. 1.84±0.81; P=0.04) to achieve a similar success rate (84% vs. 81%; P=0.833). CONCLUSION: The addition of EGM-guided ablation requires fewer procedures to achieve similar clinical efficacy in mid-term follow-up compared with a PVI-only strategy in patients with PsAF presenting for ablation in SR.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Femenino , Francia , Humanos , Londres , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Venas Pulmonares/fisiopatología , Recurrencia , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
15.
Med Phys ; 40(7): 071902, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23822439

RESUMEN

PURPOSE: X-ray fluoroscopically guided cardiac electrophysiology (EP) procedures are commonly carried out to treat patients with arrhythmias. X-ray images have poor soft tissue contrast and, for this reason, overlay of a three-dimensional (3D) roadmap derived from preprocedural volumetric images can be used to add anatomical information. It is useful to know the position of the catheter electrodes relative to the cardiac anatomy, for example, to record ablation therapy locations during atrial fibrillation therapy. Also, the electrode positions of the coronary sinus (CS) catheter or lasso catheter can be used for road map motion correction. METHODS: In this paper, the authors present a novel unified computational framework for image-based catheter detection and tracking without any user interaction. The proposed framework includes fast blob detection, shape-constrained searching and model-based detection. In addition, catheter tracking methods were designed based on the customized catheter models input from the detection method. Three real-time detection and tracking methods are derived from the computational framework to detect or track the three most common types of catheters in EP procedures: the ablation catheter, the CS catheter, and the lasso catheter. Since the proposed methods use the same blob detection method to extract key information from x-ray images, the ablation, CS, and lasso catheters can be detected and tracked simultaneously in real-time. RESULTS: The catheter detection methods were tested on 105 different clinical fluoroscopy sequences taken from 31 clinical procedures. Two-dimensional (2D) detection errors of 0.50 ± 0.29, 0.92 ± 0.61, and 0.63 ± 0.45 mm as well as success rates of 99.4%, 97.2%, and 88.9% were achieved for the CS catheter, ablation catheter, and lasso catheter, respectively. With the tracking method, accuracies were increased to 0.45 ± 0.28, 0.64 ± 0.37, and 0.53 ± 0.38 mm and success rates increased to 100%, 99.2%, and 96.5% for the CS, ablation, and lasso catheters, respectively. Subjective clinical evaluation by three experienced electrophysiologists showed that the detection and tracking results were clinically acceptable. CONCLUSIONS: The proposed detection and tracking methods are automatic and can detect and track CS, ablation, and lasso catheters simultaneously and in real-time. The accuracy of the proposed methods is sub-mm and the methods are robust toward low-dose x-ray fluoroscopic images, which are mainly used during EP procedures to maintain low radiation dose.


Asunto(s)
Catéteres , Técnicas Electrofisiológicas Cardíacas/instrumentación , Ablación por Catéter , Fluoroscopía , Humanos , Factores de Tiempo
18.
Heart Rhythm ; 7(1): 2-8, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19962945

RESUMEN

BACKGROUND: Peri-mitral atrial flutter (PMFL) is commonly encountered in patients undergoing atrial fibrillation (AF) ablation. OBJECTIVE: The purpose of this study was to determine the electrophysiologic characteristics, procedural success, and medium-term outcomes in patients with PMFL. METHODS: The study consisted of 50 consecutive patients (45 men and 5 women, age 57 +/- 12 years) with PMFL following or during AF ablation. Of the 50 PMFLs, 24 occurred during AF ablation (16 at index ablation and 8 at repeat procedure for recurrent AF), and 26 developed during follow-up. Ablation of PMFL was performed by creating a linear lesion joining the mitral annulus to the left inferior pulmonary vein. RESULTS: The incidence of PMFL was higher in patients with mitral isthmus (MI) ablation performed during AF ablation, prior to the development of PMFL, than in those in whom MI ablation was not performed (23% vs 8%, P = .04). Following the procedure, PMFL was more frequent in patients with prior MI ablation than in those without (41% vs 15%, P <.01). Seventy percent (35/50) were terminated by ablation with 6.4 +/- 6.9 minutes of radiofrequency application. Among patients in whom PMFL terminated, supplemental ablation was required for bidirectional conduction block in 66% (23/35). MI block was achieved in 92% (46/50) using 13.6 +/- 7.4 minutes of ablation. At mean follow-up of 19 +/- 4 months, 96% of patients were free from PMFL. CONCLUSION: PMFL can be terminated by MI ablation, but the procedure is proarrhythmic. Supplemental ablation is necessary to establish bidirectional block of the line despite termination of PMFL in the majority of patients.


Asunto(s)
Fibrilación Atrial/cirugía , Aleteo Atrial/etiología , Ablación por Catéter/efectos adversos , Válvula Mitral/cirugía , Fibrilación Atrial/complicaciones , Aleteo Atrial/epidemiología , Aleteo Atrial/cirugía , Técnicas Electrofisiológicas Cardíacas , Femenino , Francia/epidemiología , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Válvula Mitral/fisiopatología , Estudios Prospectivos , Venas Pulmonares , Reoperación , Factores de Riesgo
19.
J Am Coll Cardiol ; 51(10): 1003-10, 2008 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-18325439

RESUMEN

OBJECTIVES: This study sought to determine the characteristics of atrial electrograms predictive of slowing or termination of atrial fibrillation (AF) during ablation of chronic AF. BACKGROUND: There is growing recognition of a role for electrogram-based ablation. METHODS: Forty consecutive patients (34 male, 59 +/- 10 years) undergoing ablation for chronic AF persisting for a median of 12 months (range 1 to 84 months) were included. After pulmonary vein isolation and roof line ablation, electrogram-based ablation was performed in the left atrium and coronary sinus. Targeted electrograms were acquired in a 4-s window and characterized by: 1) percentage of continuous electrical activity; 2) bipolar voltage; 3) dominant frequency; 4) fractionation index; 5) mean absolute value of derivatives of electrograms; 6) local cycle length; and 7) presence of a temporal gradient of activation. Electrogram characteristics at favorable ablation regions, defined as those associated with slowing (a >or=6-ms increase in AF cycle length) or termination of AF were compared with those at unfavorable regions. RESULTS: The AF was terminated by electrogram-based ablation in 29 patients (73%) after targeting a total of 171 regions. Ablation at 37 (22%) of these regions was followed by AF slowing, and at 29 (17%) by AF termination. The percentage of continuous electrical activity and the presence of a temporal gradient of activation were independent predictors of favorable ablation regions (p = 0.016 and p = 0.038, respectively). Other electrogram characteristics at favorable ablation regions were not significantly different from those at unfavorable ablation regions. CONCLUSIONS: Catheter ablation at sites displaying a greater percentage of continuous activity or a temporal activation gradient is associated with slowing or termination of chronic AF.


Asunto(s)
Fibrilación Atrial/fisiopatología , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/cirugía , Electrocardiografía , Femenino , Cardiopatías/complicaciones , Humanos , Masculino , Persona de Mediana Edad
20.
J Cardiovasc Electrophysiol ; 18(11): 1140-6, 2007 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17711438

RESUMEN

INTRODUCTION: The coronary sinus (CS) is a complex structure comprising a mesh of circumferential muscular fibers with oblique connections to both atria. We describe further evidence for the clinical importance of CS arrhythmogenicity in maintaining atrial fibrillation (AF) in humans. METHODS: Since January 2004, following a sequential approach, the CS and the inferior left atrium were ablated in 144 patients with symptomatic drug refractory AF. Patients were included for analysis when this step resulted in the electrical dissociation of the CS from both atria with restoration of sinus rhythm, but with continued arrhythmic activity in the CS. The electrophysiologic mechanism of the confined arrhythmia was considered as focal activity (automaticity or triggered activity) by the presence of electrograms spanning less than 75% of the cycle length in the CS. RESULTS: After restoration of sinus rhythm, four male patients (3% of the patients, three persistent and one permanent AF) were identified in whom arrhythmia continued within the CS. Repetitive activity confined to the disconnected CS was inconsistent in occurrence, as well as in duration (1 sec to 15 min) and cycle length (from 158 to 380 ms). For all four patients, electrogram mapping of the entire CS was compatible with a focal mechanism. In two patients, bursts alternating with slow dissociated activity suggested automaticity. In one patient, local activity consistently coupled to the previous sinus beat favored triggered activity. CONCLUSIONS: This study provides evidence that the CS may be a potential source of focal rapid activity maintaining AF.


Asunto(s)
Fibrilación Atrial/fisiopatología , Seno Coronario/fisiopatología , Adulto , Fibrilación Atrial/cirugía , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS