Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Métodos Terapéuticos y Terapias MTCI
Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Am J Surg ; 208(6): 1078-82; discussion 1082, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25440491

RESUMEN

BACKGROUND: Traumatic hemothorax (HTX) has been demonstrated to predictably contain low fibrinogen, low hematocrit, and low platelet counts. When analyzed on its own, shed HTX demonstrates coagulopathy. However, when mixed with normal pooled plasma (NPP) at physiologically relevant dilutions, HTX demonstrates accelerated coagulation. We hypothesize that when HTX is mixed with a patient's own plasma, the mixture will demonstrate hypercoagulability. The accelerated coagulation of this mixture would have important implications for the autotransfusion of HTX as a method of resuscitating a trauma patient. METHODS: Adult trauma patients from whom greater than 140 mL of HTX was evacuated within 1 hour of tube thoracostomy were included. HTX was sampled at 1 hour after evacuation, and a portion of the sample was centrifuged and stored as frozen plasma for later analysis. The remainder of the sample was analyzed (coagulation, hematology, electrolytes), and values were compared with concurrent venous values extracted via chart review. A citrate tube containing the patient's venous blood was additionally spun down and frozen for subsequent mixing study analysis. Coagulation was further evaluated by mixing serial dilutions of the previously frozen HTX with NPP. Additionally, the previously frozen HTX was mixed in serial dilutions with the previously frozen sample of patient plasma (PTP). RESULTS: Subjects (10) were enrolled based on inclusion criteria and collection of a discarded venous sample. In HTX samples analyzed alone, no thrombus was formed in any coagulation test (activated partial thromboplastin time [aPTT] > 180). The median aPTT value of PTP alone was 25.5. In 1-hour specimens mixed at a clinically relevant dilution of 1:4, HTX mixed with NPP had a mediana PTT value of 26.0, whereas HTX mixed with PTP had a median aPTT value of 21.7. Thus, the mixture of HTX + PTP demonstrated a statistically significantly lower aPTT than the mixture of HTX + NPP (P = 0.01). Additionally, the mixture of HTX and PTP shows a statistically significantly lower aPTT value than PTP alone (P = 0.03), indicating a hypercoagulable state. CONCLUSIONS: HTX demonstrates coagulopathy when analyzed independently, but is hypercoagulable when mixed with NPP or PTP. Furthermore, mixing studies show a statistically significantly lower aPTT when HTX is mixed with PTP versus HTX mixed with NPP. Thus, autotransfusion of HTX would likely produce a hypercoagulable state in vivo, and should not be used in place of other blood products to resuscitate a trauma patient. The autotransfusion of HTX may, however, be of use in a resource-limited environment where other blood products are not available.


Asunto(s)
Trastornos de la Coagulación Sanguínea/diagnóstico , Trastornos de la Coagulación Sanguínea/etiología , Hemotórax/sangre , Adulto , Análisis Químico de la Sangre , Recolección de Muestras de Sangre/métodos , Transfusión de Sangre Autóloga , Tubos Torácicos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Texas
2.
Am J Surg ; 206(6): 904-9; discussion 909-10, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24296097

RESUMEN

BACKGROUND: The evacuated hemothorax has been poorly described because it varies with time, it has been found to be incoagulable, and its potential effect on the coagulation cascade during autotransfusion is largely unknown. METHODS: This is a prospective descriptive study of adult patients with traumatic chest injury necessitating tube thoracostomy. Pleural and venous samples were analyzed for coagulation, hematology, and electrolytes at 1 to 4 hours after drainage. Pleural samples were also analyzed for their effect on the coagulation cascade via mixing studies. RESULTS: Thirty-four subjects were enrolled with a traumatic hemothorax. The following measured coagulation factors were significantly depleted compared with venous blood: international normalized ratio (>9 vs 1.1) (P < .001) and activated partial thromboplastin time (aPTT) (>180 vs 24.5 seconds) (P < .001). Mixing studies showed a dose-dependent increase in coagulation dilutions through 1:8 (P < .05). CONCLUSIONS: An evacuated hemothorax does not vary in composition significantly with time and is incoagulable alone. Mixing studies with hemothorax plasma increased coagulation, raising safety concerns.


Asunto(s)
Coagulación Sanguínea/fisiología , Transfusión de Sangre Autóloga/métodos , Drenaje/métodos , Hemotórax/terapia , Traumatismos Torácicos/complicaciones , Toracotomía/métodos , Adulto , Femenino , Estudios de Seguimiento , Hemotórax/sangre , Hemotórax/etiología , Humanos , Masculino , Persona de Mediana Edad , Tiempo de Tromboplastina Parcial , Estudios Prospectivos , Traumatismos Torácicos/sangre , Traumatismos Torácicos/cirugía , Resultado del Tratamiento , Cicatrización de Heridas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA