Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
BMC Anesthesiol ; 22(1): 207, 2022 07 06.
Artículo en Inglés | MEDLINE | ID: mdl-35794519

RESUMEN

BACKGROUND: Dynamic obstruction of the left ventricular outflow tract resulting from systolic anterior motion of the mitral valve can be an unexpected cause of acute and severe perioperative hypotension in noncardiac surgery. We report a patient undergoing spinal anesthesia for transurethral resection of the prostate who experienced sudden hypoxemia caused by systolic anterior motion-induced mitral regurgitation but with a clinically picture simulating fluid overload. CASE PRESENTATION: An 83-year-old man with a history of hypertension was scheduled for transurethral resection of the prostate. One hour after spinal anesthesia, he developed acute restlessness and dyspnea, with pink frothy sputum and progressive hypoxemia. Slight hypertension was noted, and an electrocardiogram showed atrial fibrillation with a rapid ventricular response. Furosemide and nitroglycerin were thus administered for suspected fluid overload or transurethral resection of the prostate syndrome; however, he then became severely hypotensive. After tracheal intubation, intraoperative transesophageal echocardiography was promptly performed, which revealed an empty hypercontractile left ventricle, significant mitral regurgitation and mosaic flow signal in the left ventricular outflow tract. Following aggressive fluid therapy, his hemodynamic changes stabilized. Repeat echocardiography in intensive care unit confirmed the presence of systolic anterior motion of the anterior mitral leaflet obstructing the left ventricular outflow tract. We speculate that pulmonary edema was induced by systolic anterior motion-associated mitral regurgitation and rapid atrial fibrillation, and the initial management had worsened his hypovolemia and provoked left ventricular outflow tract obstruction and hemodynamic instability. CONCLUSIONS: Pulmonary edema caused by systolic anterior motion of the mitral valve can be difficult to clinically differentiate from that induced by fluid overload. Therefore, bedside echocardiography is paramount for timely diagnosis and prompt initiation of appropriate therapy in the perioperative care setting.


Asunto(s)
Anestesia Raquidea , Fibrilación Atrial , Insuficiencia de la Válvula Mitral , Edema Pulmonar , Resección Transuretral de la Próstata , Anciano de 80 o más Años , Anestesia Raquidea/efectos adversos , Humanos , Hipoxia , Masculino , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Edema Pulmonar/etiología , Resección Transuretral de la Próstata/efectos adversos
2.
Intensive Care Med ; 40(10): 1509-17, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25091791

RESUMEN

INTRODUCTION: Although statins have been shown to have cholesterol-lowering effects, their pleiotropic benefits on sepsis remain a matter of debate. In addition, the influence of statin potency on sepsis-related mortality has never been explored. The aim of our study was to determine the sepsis outcomes of low- and high-potency statin users and non-users. METHODS: This nationwide, population-based, propensity score-matched analysis used data from the linked administrative databases of Taiwan's National Health Insurance program. Patients were hospitalized for sepsis between 2000 and 2010. All-cause mortality and major adverse consequences of sepsis, such as in-hospital death, intensive care unit admission, shock events, and the use of mechanical ventilation, were assessed. Patients were divided into high-potency statin users (at least 10 mg rosuvastatin, at least 20 mg atorvastatin, or at least 40 mg simvastatin), low-potency statin users (all other statin treatments), and non-users. RESULTS: A propensity score-matched cohort of 27,792 statin users and 27,792 non-users was included. Of 27,792 statin users, 9,785 (35.2 %) were treated with high-potency statins and 18,007 (64.8 %) were treated with low-potency statins. The 1-year mortality risk was significantly lower among both low-potency [adjusted hazard ratio (aHR) 0.89, 95 % confidence interval (CI) 0.85-0.93] and high-potency (aHR 0.80, 95 % CI 0.75-0.86) statin users compared with non-users. The risks of mortality and adverse consequences of sepsis were lower among high-potency than among low-potency statin users. CONCLUSIONS: High-potency statin use is associated with a lower risk of sepsis-related mortality compared with low-potency statin use.


Asunto(s)
Inhibidores de Hidroximetilglutaril-CoA Reductasas/administración & dosificación , Sepsis/tratamiento farmacológico , Sepsis/mortalidad , Anciano , Comorbilidad , Femenino , Mortalidad Hospitalaria , Humanos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Revisión de Utilización de Seguros/estadística & datos numéricos , Estimación de Kaplan-Meier , Masculino , Programas Nacionales de Salud/estadística & datos numéricos , Evaluación de Procesos y Resultados en Atención de Salud/estadística & datos numéricos , Puntaje de Propensión , Modelos de Riesgos Proporcionales , Medición de Riesgo , Sepsis/complicaciones , Taiwán/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA