Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Audiol Neurootol ; 25(1-2): 91-95, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31661687

RESUMEN

INTRODUCTION: The vestibular implant could become a clinically useful device in the near future. This study investigated the feasibility of restoring the high-frequency dynamic visual acuity (DVA) with a vestibular implant, using the functional Head Impulse Test (fHIT). METHODS: A 72-year-old female, with bilateral vestibulopathy and fitted with a modified cochlear implant incorporating three vestibular electrodes (MED-EL, Innsbruck, Austria), was available for this study. Electrical stimulation was delivered with the electrode close to the lateral ampullary nerve in the left ear. The high-frequency DVA in the horizontal plane was tested with the fHIT. After training, the patient underwent six trials of fHIT, each with a different setting of the vestibular implant: (1) System OFF before stimulation; (2) System ON, baseline stimulation; (3) System ON, reversed stimulation; (4) System ON, positive stimulation; (5) System OFF, without delay after stimulation offset; and (6) System OFF, 25 min delay after stimulation offset. The percentage of correct fHIT scores for right and left head impulses were compared between trials. RESULTS: Vestibular implant stimulation improved the high-frequency DVA compared to no stimulation. This improvement was significant for "System ON, baseline stimulation" (p = 0.02) and "System ON, positive stimulation" (p < 0.001). fHIT scores changed from 19 to 44% (no stimulation) to maximum 75-94% (System ON, positive stimulation). CONCLUSION: The vestibular implant seems capable of improving the high-frequency DVA. This functional benefit of the vestibular implant illustrates again the feasibility of this device for clinical use in the near future.


Asunto(s)
Vestibulopatía Bilateral/terapia , Implantes Cocleares , Terapia por Estimulación Eléctrica , Vestíbulo del Laberinto/fisiopatología , Agudeza Visual/fisiología , Anciano , Austria , Vestibulopatía Bilateral/fisiopatología , Femenino , Prueba de Impulso Cefálico , Humanos , Resultado del Tratamiento , Nervio Vestibular/fisiopatología
2.
Vision Res ; 48(16): 1705-1718, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18572220

RESUMEN

Retinal prostheses attempt to restore some amount of vision to totally blind patients. Vision evoked this way will be however severely constrained because of several factors (e.g., size of the implanted device, number of stimulating contacts, etc.). We used simulations of artificial vision to study how such restrictions of the amount of visual information provided would affect performance on simple pointing and manipulation tasks. Five normal subjects participated in the study. Two tasks were used: pointing on random targets (LEDs task) and arranging wooden chips according to a given model (CHIPs task). Both tasks had to be completed while the amount of visual information was limited by reducing the resolution (number of pixels) and modifying the size of the effective field of view. All images were projected on a 10 degrees x 7 degrees viewing area, stabilised at a given position on the retina. In central vision, the time required to accomplish the tasks remained systematically slower than with normal vision. Accuracy was close to normal at high image resolutions and decreased at 500 pixels or below, depending on the field of view used. Subjects adapted quite rapidly (in less than 15 sessions) to performing both tasks in eccentric vision (15 degrees in the lower visual field), achieving after adaptation performances close to those observed in central vision. These results demonstrate that, if vision is restricted to a small visual area stabilised on the retina (as would be the case in a retinal prosthesis), the perception of several hundreds of retinotopically arranged phosphenes is still needed to restore accurate but slow performance on pointing and manipulation tasks. Considering that present prototypes afford less than 100 stimulation contacts and that our simulations represent the most favourable visual input conditions that the user might experience, further development is required to achieve optimal rehabilitation prospects.


Asunto(s)
Ceguera/rehabilitación , Terapia por Estimulación Eléctrica/métodos , Percepción de Forma/fisiología , Prótesis e Implantes , Desempeño Psicomotor , Adaptación Fisiológica/fisiología , Adulto , Ceguera/fisiopatología , Terapia por Estimulación Eléctrica/instrumentación , Femenino , Humanos , Aprendizaje/fisiología , Masculino , Psicofísica , Campos Visuales/fisiología , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA