Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Nat Commun ; 13(1): 513, 2022 01 26.
Artículo en Inglés | MEDLINE | ID: mdl-35082313

RESUMEN

Loss of photoreceptors in atrophic age-related macular degeneration (AMD) results in severe visual impairment. Since the low-resolution peripheral vision is retained in such conditions, restoration of central vision should not jeopardize the surrounding healthy retina and allow for simultaneous use of the natural and prosthetic sight. This interim report, prespecified in the study protocol, presents the first clinical results with a photovoltaic substitute of the photoreceptors providing simultaneous use of the central prosthetic and peripheral natural vision in atrophic AMD. In this open-label single group feasibility trial (NCT03333954, recruitment completed), five patients with geographic atrophy have been implanted with a wireless 2 x 2 mm-wide 30 µm-thick device, having 378 pixels of 100 µm in size. All 5 patients achieved the primary outcome of the study by demonstrating the prosthetic visual perception in the former scotoma. The four patients with a subretinal placement of the chip demonstrated the secondary outcome: Landolt acuity of 1.17 ± 0.13 pixels, corresponding to the Snellen range of 20/460-20/565. With electronic magnification of up to a factor of 8, patients demonstrated prosthetic acuity in the range of 20/63-20/98. Under room lighting conditions, patients could simultaneously use prosthetic central vision and their remaining peripheral vision in the implanted eye and in the fellow eye.


Asunto(s)
Terapia por Estimulación Eléctrica/instrumentación , Terapia por Estimulación Eléctrica/métodos , Atrofia Geográfica/terapia , Degeneración Macular/terapia , Trastornos de la Visión/terapia , Percepción Visual , Prótesis Visuales , Anciano , Anciano de 80 o más Años , Estimulación Eléctrica , Diseño de Equipo , Anteojos , Humanos , Retina , Resultado del Tratamiento , Agudeza Visual
2.
J Neural Eng ; 4(1): S72-84, 2007 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-17325419

RESUMEN

The design of high-resolution retinal prostheses presents many unique engineering and biological challenges. Ever smaller electrodes must inject enough charge to stimulate nerve cells, within electrochemically safe voltage limits. Stimulation sites should be placed within an electrode diameter from the target cells to prevent 'blurring' and minimize current. Signals must be delivered wirelessly from an external source to a large number of electrodes, and visual information should, ideally, maintain its natural link to eye movements. Finally, a good system must have a wide range of stimulation currents, external control of image processing and the option of either anodic-first or cathodic-first pulses. This paper discusses these challenges and presents solutions to them for a system based on a photodiode array implant. Video frames are processed and imaged onto the retinal implant by a head-mounted near-to-eye projection system operating at near-infrared wavelengths. Photodiodes convert light into pulsed electric current, with charge injection maximized by applying a common biphasic bias waveform. The resulting prosthesis will provide stimulation with a frame rate of up to 50 Hz in a central 10 degrees visual field, with a full 30 degrees field accessible via eye movements. Pixel sizes are scalable from 100 to 25 microm, corresponding to 640-10,000 pixels on an implant 3 mm in diameter.


Asunto(s)
Terapia por Estimulación Eléctrica/instrumentación , Electrodos Implantados , Electrónica Médica/instrumentación , Óptica y Fotónica/instrumentación , Prótesis e Implantes , Enfermedades de la Retina/rehabilitación , Grabación en Video/instrumentación , Animales , Inteligencia Artificial , Terapia por Estimulación Eléctrica/métodos , Análisis de Falla de Equipo , Humanos , Interpretación de Imagen Asistida por Computador/instrumentación , Microelectrodos , Diseño de Prótesis , Retina/cirugía , Terapia Asistida por Computador/instrumentación , Terapia Asistida por Computador/métodos , Grabación en Video/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA