Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiothorac Surg ; 16(1): 95, 2021 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-33879212

RESUMEN

BACKGROUND: The aim of this study is to compare the diagnostic efficacy and safety of video-assisted thoracoscopic surgery (VATS) with awake VATS (AVATS) pleural biopsy in undiagnosed exudative pleural effusions. METHODS: The diagnostic efficacy of pleural biopsy by uniportal VATS under general anesthesia or AVATS under local anesthesia and sedation performed by the same surgeon in patients with undiagnosed exudative pleural effusion between 2007 and 2020 were retrospectively evaluated. Test sensitivity, specificity, positive predictive value and negative predictive value were compared as well as age, gender, comorbidities, procedure safety, additional pleural-based interventions, duration time of operation and length of hospital stay. RESULTS: Of 154 patients with undiagnosed exudative pleural effusion, 113 (73.37%) underwent pleural biopsy and drainage with VATS, while 41 (26.62%) underwent AVATS pleural biopsy. Sensitivity, specificity, positive predictive value and negative predictive value were 92, 100, 100, and 85.71% for VATS, and 83.3, 100, 100, and 78.9% for AVATS, respectively. There was no significant difference in diagnostic test performance between the groups, (p = 0.219). There was no difference in the rate of complications [15 VATS (13.3) versus 4 AVATS (9.8%), p = 0.557]. Considering additional pleural-based interventions, while pleural decortication was performed in 13 (11.5%) cases in the VATS group, no pleural decortication was performed in AVATS group, (p = 0.021). AVATS group was associated with shorter duration time of operation than VATS (22.17 + 6.57 min. Versus 51.93 + 8.85 min., p < 0.001). Length of hospital stay was relatively shorter in AVATS but this was not statistically significant different (p = 0.063). CONCLUSIONS: Our study revealed that uniportal AVATS pleural biopsy has a similar diagnostic efficacy and safety profile with VATS in the diagnosis and treatment of patients with undiagnosed pleural effusion who have a high risk of general anesthesia due to advanced age and comorbidities. Accordingly, uniportal AVATS pleural biopsy may be considered in the diagnosis and treatment of all exudative undiagnosed pleural effusions.


Asunto(s)
Anestesia General , Anestesia Local , Sedación Consciente , Pleura/patología , Derrame Pleural/etiología , Derrame Pleural/patología , Cirugía Torácica Asistida por Video/métodos , Adulto , Anciano , Anciano de 80 o más Años , Biopsia , Femenino , Estudios de Seguimiento , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Tempo Operativo , Evaluación de Resultado en la Atención de Salud , Pleura/cirugía , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Sensibilidad y Especificidad , Vigilia
2.
Minerva Anestesiol ; 85(7): 746-755, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30621372

RESUMEN

BACKGROUND: It has been reported that noninvasive, objective tests are needed for determining the success of peripheral nerve blocks because conventional methods necessitate the cooperation of the patient. It is also known that the brachial plexus block causes vasodilatation and an increase in blood flow due to its sympathectomy effect. Our study aimed to determine whether Perfusion Index (PI) and measured regional hemodynamic changes using ultrasound were reliable parameters in evaluating the early success of an infraclavicular block. METHODS: Forty ASA I-III patients who were administered a successful infraclavicular block were included in this study. In addition to the baseline hemodynamic measurements, PI and regional hemodynamic parameters, such as brachial artery diameter (BAD), brachial arterial area (BAA), blood flow (BF), end-diastolic velocity (EDV), Resistance Index (RI), peak systolic velocity (PSV), and time average velocity (TAV) were measured. After completing the block procedure, all values were rerecorded at the 10th, 20th, and 30th minute. Patients with a successful block during the first 10 minutes were assigned to Group A, while patients with a successful block after the 10th minute were assigned to Group B. RESULTS: Statistically significant differences were observed for all regional hemodynamic variables and PI after 10 minutes. When the regional hemodynamic data and PI were compared between the groups, differences were identified for PI, BF, PSV, EDV, and TAV. Within the measured parameters, EDV was the parameter showing the greatest proportional change. CONCLUSIONS: Changes in EDV, especially RI and PI, provide more effective and objective results for the assessment of early regional block success.


Asunto(s)
Bloqueo Nervioso/métodos , Índice de Perfusión , Ultrasonografía Doppler , Adulto , Anestésicos Locales , Velocidad del Flujo Sanguíneo , Femenino , Hemodinámica , Humanos , Lidocaína , Masculino , Persona de Mediana Edad , Estimulación Eléctrica Transcutánea del Nervio/métodos , Extremidad Superior/irrigación sanguínea , Extremidad Superior/cirugía , Adulto Joven
3.
J Pak Med Assoc ; 66(4): 447-52, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27122274

RESUMEN

OBJECTIVE: To evaluate the changing levels of selenium, copper, zinc and iron in patients with sepsis and systemic inflammatory response syndrome and their influence on mortality. METHODS: The prospective study was conducted at a tertiary care university hospital in Zonguldak city in the western Black Sea region of Turkey from January 2012 to December 2013, and comprised patients with sepsis and systemic inflammatory response syndrome. Blood samples were taken on 1st, 3rd, 5th and 7th days to measure serum selenium, copper, zinc and iron levels. Patients' demographic data, presence of additional diseases and mortality were recorded. RESULTS: Of the 57 patients, 28(49.1%) were female and 29(50.9%) were male, with an overall mean age of 60.3±19.4 years, mean height of 166.1±11.4cm, mean weight of 76.5±17.5kg. Copper and zinc levels were in the normal range, while selenium and iron levels were lower than the limit values at all measuring periods. There was no significant difference between first and other days in accordance with element levels (p>0.05). Baseline copper levels in patients with malignancy were lower than patients without malignancy (p< 0.05). In hypertensive patients, baseline copper levels were higher and 7th day levels were lower than non-hypertensive (p< 0.05). Baseline selenium levels of those who died were lower than the other patients (p< 0.05). Selenium and iron levels were decreased in patients with sepsis-systemic inflammatory response syndrome and copper levels were lower in patients with malignancy, hypertension and chronic obstructive pulmonary disease (p< 0.05). There was no change in zinc levels of the patients. CONCLUSIONS: Reduced basal selenium levels of patients with sepsis and systemic inflammatory response syndrome were associated with mortality.


Asunto(s)
Cobre/sangre , Hierro/sangre , Selenio/sangre , Sepsis/sangre , Zinc/sangre , Adulto , Anciano , Comorbilidad , Diabetes Mellitus/epidemiología , Progresión de la Enfermedad , Femenino , Cardiopatías/epidemiología , Humanos , Hipertensión/epidemiología , Masculino , Persona de Mediana Edad , Neoplasias/epidemiología , Pronóstico , Estudios Prospectivos , Enfermedad Pulmonar Obstructiva Crónica/epidemiología , Insuficiencia Renal/epidemiología , Sepsis/mortalidad , Síndrome de Respuesta Inflamatoria Sistémica/sangre , Síndrome de Respuesta Inflamatoria Sistémica/mortalidad , Centros de Atención Terciaria , Turquía/epidemiología , Heridas y Lesiones/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA