Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Nat Commun ; 13(1): 4374, 2022 07 28.
Artículo en Inglés | MEDLINE | ID: mdl-35902577

RESUMEN

Exposure to traumatic stress can lead to fear dysregulation, which has been associated with posttraumatic stress disorder (PTSD). Previous work showed that a polymorphism in the PACAP-PAC1R (pituitary adenylate cyclase-activating polypeptide) system is associated with PTSD risk in women, and PACAP (ADCYAP1)-PAC1R (ADCYAP1R1) are highly expressed in the hypothalamus. Here, we show that female mice subjected to acute stress immobilization (IMO) have fear extinction impairments related to Adcyap1 and Adcyap1r1 mRNA upregulation in the hypothalamus, PACAP-c-Fos downregulation in the Medial Amygdala (MeA), and PACAP-FosB/ΔFosB upregulation in the Ventromedial Hypothalamus dorsomedial part (VMHdm). DREADD-mediated inhibition of MeA neurons projecting to the VMHdm during IMO rescues both PACAP upregulation in VMHdm and the fear extinction impairment. We also found that women with the risk genotype of ADCYAP1R1 rs2267735 polymorphism have impaired fear extinction.


Asunto(s)
Polipéptido Hipofisario Activador de la Adenilato-Ciclasa/metabolismo , Receptores del Polipéptido Activador de la Adenilato-Ciclasa Hipofisaria , Animales , Extinción Psicológica , Miedo/fisiología , Femenino , Humanos , Hipotálamo/metabolismo , Ratones , Receptores del Polipéptido Activador de la Adenilato-Ciclasa Hipofisaria/genética , Receptores del Polipéptido Activador de la Adenilato-Ciclasa Hipofisaria/metabolismo
2.
J Chromatogr A ; 1202(2): 132-7, 2008 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-18640681

RESUMEN

The performance of microHPLC-microconcentric nebulizer-inductively coupled plasma-mass spectrometry (ICP-MS) coupling for the simultaneous determination of As(III), As(V), monomethylarsenic acid (MMA), dimethylarsinic acid (DMA), selenite (SeIV) and selenate (SeVI) in water was evaluated. The accurate reduction of the off-column dead volume, specially the capillary of the micronebulizer, as well as the optimization of chromatographic conditions led to the claimed advantages expected for microbore columns: a significant diminution of sample and solvent consumption without sacrificing sensitivity and the overall resolution in faster analysis time (less than 5 min). Detection limits are in the range 0.03-0.04 microg L(-1) for arsenic species and 0.35 microg L(-1) for selenium species. The developed method was validated by analysing different spiked environmental water samples. Linearity, tested up to 50 microg L(-1), showed correlation coefficients above 0.999 and no matrix effect for high saline water samples. Good accuracy and repeatability was obtained for spiked influent and effluent water treatment plant.


Asunto(s)
Arsénico/análisis , Cromatografía Líquida de Alta Presión/métodos , Espectrometría de Masas/métodos , Selenio/análisis , Ácido Cacodílico/análisis , Cromatografía Líquida de Alta Presión/instrumentación , Reproducibilidad de los Resultados , Ácido Selénico , Compuestos de Selenio/análisis , Selenito de Sodio/análisis , Contaminantes Químicos del Agua/análisis , Abastecimiento de Agua/análisis
3.
J Chromatogr A ; 1172(2): 179-85, 2007 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-17959190

RESUMEN

Relevant secondary interactions (hydrogen-bond type), additional to the main anion-exchange mechanism, were found when a method for As, Se and Cr speciation was developed based on microLC-inductively coupled plasma mass spectrometry (ICP-MS) coupling. In order to get the claimed analytical performance characteristics of the microbore columns, microLC systems are equipped with very narrow bore fused silica capillaries. When a mobile phase of NH(4)NO(3) at pH 8.7 was used, a notable tailing was observed for As(III), As(V), MMA and Se(IV), species containing hydroxyl groups in its chemical structure at this pH value. However, additional interactions appeared neither when the fused silica capillaries of the capillary LC system were substituted for polyetheretherketone (PEEK) nor operating at pH below 8.5. A mechanism to explain the additional interaction observed is proposed and tested in this work. It seems that high pH values produce a partial hydrolysis of the siloxane groups of the fused silica capillaries. Under these conditions, degradation products of silica, containing ionized silanol groups, reach the column and interact with the anion-exchange resin. Then, ionized silanol groups, retained on the column, can interact with the hydroxyl moiety of the aforementioned analytes leading to severe peak tailing and broadening. Different strategies were evaluated to solve the problem. The addition of a salt containing hydroxyl groups in the mobile phase such as hydrogen phosphate, the diminution of the pH and the use of PEEK capillaries in the microHPLC system demonstrated to be suitable. Finally, two alternative microHPLC-ICP-MS separations, based on a gradient elution of NH(4)NO(3) at pH 8.0 and NH(4)NO(3)/NH(4)H(2)PO(4) at pH 8.7, were optimized and compared. Results showed better peak shapes for some species when hydrogen phosphate was added to the mobile phase.


Asunto(s)
Resinas de Intercambio Aniónico/química , Arsenicales/análisis , Cromatografía Líquida de Alta Presión/métodos , Cromo/análisis , Miniaturización/instrumentación , Selenio/análisis , Cromatografía Líquida de Alta Presión/instrumentación , Cromatografía por Intercambio Iónico/métodos , Enlace de Hidrógeno , Concentración de Iones de Hidrógeno , Hidróxidos/química , Nitratos/química , Siloxanos/química , Espectrofotometría Atómica/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA