Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 35(5): 942-949, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38462681

RESUMEN

INTRODUCTION: Mapping system is useful in ablation of atrioventricular nodal reentry tachycardia (AVNRT) and localization of anatomic variances. Voltage mapping identifies a low voltage area in the Koch triangle called low-voltage-bridge (LVB); propagation mapping identifies the collision point (CP) of atrial wavefront convergence. We conducted a prospective study to evaluate the relationship between LVB and CP with successful site of ablation and identify standard value for LVB. MATERIALS AND METHODS: Three-dimensional (3D) maps of the right atria were constructed from intracardiac recordings using the ablation catheter. Cut-off values on voltage map were adjusted until LVB was observed. On propagation map, atrial wavefronts during sinus rhythm collide in the site representing CP, indicating the area of slow pathway conduction. Ablation site was selected targeting LVB and CP site, confirmed by anatomic position on fluoroscopy and atrioventricular ratio. RESULTS: Twenty-seven consecutive patients were included. LVB and CP were present in all patients. Postprocedural evaluation identified standard cut-off of 0.3-1 mV useful for LVB identification. An overlap between LVB and CP was observed in 23 (85%) patients. Procedure success was achieved in all patient with effective site at first application in 22 (81%) patients. There was a significant correlation between LVB, CP, and the site of effective ablation (p = .001). CONCLUSION: We found correlation between LVB and CP with the site of effective ablation, identifying a voltage range useful for standardized LVB identification. These techniques could be useful to identify ablation site and minimize radiation exposure.


Asunto(s)
Potenciales de Acción , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Taquicardia por Reentrada en el Nodo Atrioventricular , Humanos , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Masculino , Femenino , Estudios Prospectivos , Persona de Mediana Edad , Resultado del Tratamiento , Adulto , Valor Predictivo de las Pruebas , Anciano , Nodo Atrioventricular/fisiopatología , Nodo Atrioventricular/cirugía , Factores de Tiempo
2.
J Cardiovasc Med (Hagerstown) ; 18(7): 478-489, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28514791

RESUMEN

AIMS: Atrial fibrillation recurrences after pulmonary vein isolation (PVI) are not uncommon and are frequently related to pulmonary vein reconnection. Adenosine/ATP can reveal dormant pulmonary vein conduction after PVI. Previous studies revealed that adenosine-guided Additional ablation could improve arrhythmia-free survival. We performed a meta-analysis to assess the impact of additional ablation to eliminate adenosine-induced transient pulmonary vein reconnection in terms of atrial fibrillation recurrence at follow-up. METHODS: MEDLINE/PubMed, Cochrane Library and references reporting atrial fibrillation ablation and adenosine/ATP-following PVI were screened, and studies were included if they matched inclusion and exclusion criteria. RESULTS: A total of 3524 patients were enrolled with a median follow-up of 13 (6-20) months. Overall, 70% (60-85) of patients in ATP-guided ablation vs. 63% (48-79) in no ATP-guided ablation were free of atrial fibrillation at follow-up. Pooled results revealed that ATP-guided ablation reduced the risk of atrial fibrillation recurrence of 42% [odds ratio (OR) 0.58, 0.41-0.81], but this result was primary because of the contribution of retrospective over-randomized studies [OR 0.48 (0.35-0.65) vs. 0.76 (0.42-1.40), respectively]. 3.2% of patients experienced an adverse event. ATP-guided ablation is related to a nonsignificant increase in fluoroscopy time (OR 1.71, 0.98-2.96) and to a significant increase in procedure time (OR 2.84, 1.32-6.09). CONCLUSION: Additional ablation aiming to eliminate adenosine-induced transient pulmonary vein reconnection failed to reduce the risk of atrial fibrillation recurrence at follow-up. Moreover, although adenosine-guided PVI is not affected by an augmented risk of adverse events, it is associated with a NS increased fluoroscopy exposure and significantly longer procedure duration. Further studies are required to identify the actual role of adenosine in PVI.


Asunto(s)
Adenosina Trifosfato/administración & dosificación , Adenosina/administración & dosificación , Fibrilación Atrial/cirugía , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Venas Pulmonares/cirugía , Adulto , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Valor Predictivo de las Pruebas , Venas Pulmonares/fisiopatología , Recurrencia , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA