1.
JACC Clin Electrophysiol ; 6(2): 171-181, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-32081219

RESUMEN

OBJECTIVES: This study sought to validate the accuracy of noncontact electrograms against contact electrograms in the left atrium during sinus rhythm (SR) and atrial fibrillation (AF). BACKGROUND: Noncontact mapping offers the opportunity to assess global cardiac activation in the chamber of interest. A novel noncontact mapping system, which records intracardiac voltage to derive cellular charge sources (dipole density), allows real-time mapping of AF to guide ablation. METHODS: Noncontact and contact unipolar electrogram pairs were recorded simultaneously from multiple locations. Morphology correlation and timing difference of reconstructed electrograms obtained from a noncontact catheter were compared with those from contact electrograms obtained from a contact catheter at the same endocardial locations. RESULTS: A total of 796 electrogram pairs in SR and 969 electrogram pairs in AF were compared from 20 patients with persistent AF. The median morphology correlation and timing difference (ms) in SR was 0.85 (interquartile range [IQR]: 0.71 to 0.94) and 6.4 ms (IQR: 2.6 to 17.1 ms); in AF was 0.79 (IQR: 0.69 to 0.88) and 14.4 ms (IQR: 6.7 to 26.2 ms), respectively. The correlation was stronger and the timing difference was less when the radial distance (r) from the noncontact catheter center to the endocardium was ≤ 40 versus > 40 mm; 0.87 (IQR: 0.72 to 0.94) versus 0.73 (IQR: 0.56 to 0.88) and 5.7 ms (IQR: 2.6 to 15.4 ms) versus 15.1 ms (IQR: 4.1 to 27.7 ms); p < 0.01 when in SR; 0.81 (IQR: 0.69 to 0.89) versus 0.67 (IQR: 0.45 to 0.82) and 12.3 ms (IQR: 5.9 to 21.8 ms) versus 28.3 ms (IQR: 16.2 to 36.0 ms); p < 0.01 when in AF. CONCLUSIONS: This novel noncontact dipole density mapping system provides comparable reconstructed atrial electrogram measurements in SR or AF in human left atrium when the anatomical site of interest is ≤40 mm from the mapping catheter.


Asunto(s)
Fibrilación Atrial/fisiopatología , Técnicas Electrofisiológicas Cardíacas/métodos , Atrios Cardíacos/fisiopatología , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas/normas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA