Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Radiology ; 308(3): e230524, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37698477

RESUMEN

Background The prognostic value of coronary CT angiography (CTA)-derived fractional flow reserve (FFR) beyond 1-year outcomes and in patients with high levels of coronary artery calcium (CAC) is uncertain. Purpose To assess the prognostic value of coronary CTA-derived FFR test results on 3-year clinical outcomes in patients with coronary stenosis and among a subgroup of patients with high levels of CAC. Materials and Methods This study represents a 3-year follow-up of patients with new-onset stable angina pectoris who were consecutively enrolled in the Assessing Diagnostic Value of Noninvasive CT-FFR in Coronary Care, known as ADVANCE (ClinicalTrials.gov: NCT02499679) registry, between December 2015 and October 2017 at three Danish sites. A high CAC was defined as an Agatston score of at least 400. A lesion-specific coronary CTA-derived FFR value of 2 cm with distal-to-stenosis value at or below 0.80 represented an abnormal test result. The primary end point was a composite of all-cause death and nonfatal spontaneous myocardial infarction. Event rates were estimated using the one-sample binomial model, and relative risk was compared between participants stratified by results of coronary CTA-derived FFR. Results This study included 900 participants: 523 participants with normal results (mean age, 64 years ± 9.6 [SD]; 318 male participants) and 377 with abnormal results from coronary CTA-derived FFR (mean age, 65 years ± 9.6; 264 male participants). The primary end point occurred in 11 of 523 (2.1%) and 25 of 377 (6.6%) participants with normal and abnormal coronary CTA-derived FFR results, respectively (relative risk, 3.1; 95% CI: 1.6, 6.3; P < .001). In participants with high CAC, the primary end point occurred in four of 182 (2.2%) and 19 of 212 (9.0%) participants with normal and abnormal coronary CTA-derived FFR results, respectively (relative risk, 4.1; 95% CI: 1.4, 11.8; P = .001). Conclusion In individuals with stable angina, a normal coronary CTA-derived FFR test result identified participants with a low 3-year risk of all-cause death or nonfatal spontaneous myocardial infarction, both in the overall cohort and in participants with high CAC scores. Clinical trial registration no. NCT02499679 Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Sinitsyn in this issue.


Asunto(s)
Angina Estable , Reserva del Flujo Fraccional Miocárdico , Infarto del Miocardio , Humanos , Masculino , Persona de Mediana Edad , Anciano , Angina Estable/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Pronóstico , Angiografía Coronaria , Tomografía Computarizada por Rayos X , Calcio
2.
Circulation ; 108(11): 1310-5, 2003 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-12939212

RESUMEN

BACKGROUND: Motexafin lutetium (MLu; Antrin) is a photosensitizer that is taken up by atherosclerotic plaque and concentrated within macrophages and vascular smooth muscle cells. After photoactivation with far red light, MLu facilitates production of cytotoxic oxygen radicals that mediate apoptosis. We assessed the safety and tolerability of phototherapy (PT) with MLu in patients undergoing percutaneous coronary intervention with stent deployment. METHODS AND RESULTS: An open-label, phase I, drug and light dose-escalation clinical trial of MLu PT enrolled 80 patients undergoing de novo coronary stent deployment. MLu was administered to 79 patients by intravenous infusion 18 to 24 hours before procedure, and photoactivation was performed after balloon predilatation and before stent deployment. Clinical evaluation, serial quantitative angiography, and intravascular ultrasound were performed periprocedurally and at 6 months follow-up. MLu PT was well tolerated without serious dose-limiting toxicities, and side effects (paresthesia and rash) were minor. No adverse angiographic outcomes were attributed to phototherapy. CONCLUSIONS: This study demonstrates that coronary MLu PT seems safe, and the maximum well-tolerated MLu dose and range of tolerated light doses were identified. These data can be used in phase II efficacy trials of MLu PT for the treatment of coronary atherosclerosis or vulnerable plaque.


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Metaloporfirinas/administración & dosificación , Fotoquimioterapia , Fármacos Fotosensibilizantes/administración & dosificación , Adulto , Angioplastia Coronaria con Balón , Terapia Combinada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Relación Dosis-Respuesta a Droga , Relación Dosis-Respuesta en la Radiación , Femenino , Estudios de Seguimiento , Humanos , Infusiones Intravenosas , Masculino , Metaloporfirinas/efectos adversos , Metaloporfirinas/uso terapéutico , Persona de Mediana Edad , Fotoquimioterapia/efectos adversos , Fármacos Fotosensibilizantes/efectos adversos , Fármacos Fotosensibilizantes/uso terapéutico , Stents , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA