Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Neurology ; 95(9): e1244-e1256, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-32690786

RESUMEN

OBJECTIVE: To prospectively evaluate safety and efficacy of brain-responsive neurostimulation in adults with medically intractable focal onset seizures (FOS) over 9 years. METHODS: Adults treated with brain-responsive neurostimulation in 2-year feasibility or randomized controlled trials were enrolled in a long-term prospective open label trial (LTT) to assess safety, efficacy, and quality of life (QOL) over an additional 7 years. Safety was assessed as adverse events (AEs), efficacy as median percent change in seizure frequency and responder rate, and QOL with the Quality of Life in Epilepsy (QOLIE-89) inventory. RESULTS: Of 256 patients treated in the initial trials, 230 participated in the LTT. At 9 years, the median percent reduction in seizure frequency was 75% (p < 0.0001, Wilcoxon signed rank), responder rate was 73%, and 35% had a ≥90% reduction in seizure frequency. We found that 18.4% (47 of 256) experienced ≥1 year of seizure freedom, with 62% (29 of 47) seizure-free at the last follow-up and an average seizure-free period of 3.2 years (range 1.04-9.6 years). Overall QOL and epilepsy-targeted and cognitive domains of QOLIE-89 remained significantly improved (p < 0.05). There were no serious AEs related to stimulation, and the sudden unexplained death in epilepsy (SUDEP) rate was significantly lower than predefined comparators (p < 0.05, 1-tailed χ2). CONCLUSIONS: Adjunctive brain-responsive neurostimulation provides significant and sustained reductions in the frequency of FOS with improved QOL. Stimulation was well tolerated; implantation-related AEs were typical of other neurostimulation devices; and SUDEP rates were low. CLINICALTRIALSGOV IDENTIFIER: NCT00572195. CLASSIFICATION OF EVIDENCE: This study provides Class IV evidence that brain-responsive neurostimulation significantly reduces focal seizures with acceptable safety over 9 years.


Asunto(s)
Epilepsia Refractaria/terapia , Terapia por Estimulación Eléctrica/métodos , Epilepsias Parciales/terapia , Neuroestimuladores Implantables , Calidad de Vida , Adolescente , Adulto , Anciano , Trastorno Depresivo/epidemiología , Epilepsia Refractaria/fisiopatología , Epilepsia Refractaria/psicología , Epilepsias Parciales/fisiopatología , Epilepsias Parciales/psicología , Femenino , Estudios de Seguimiento , Humanos , Hemorragias Intracraneales/epidemiología , Masculino , Trastornos de la Memoria/epidemiología , Persona de Mediana Edad , Estudios Prospectivos , Infecciones Relacionadas con Prótesis/epidemiología , Ensayos Clínicos Controlados Aleatorios como Asunto , Estado Epiléptico/epidemiología , Muerte Súbita e Inesperada en la Epilepsia/epidemiología , Suicidio/estadística & datos numéricos , Resultado del Tratamiento , Adulto Joven
2.
Epilepsia ; 61(3): 408-420, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32072621

RESUMEN

OBJECTIVE: To describe seizure outcomes in patients with medically refractory epilepsy who had evidence of bilateral mesial temporal lobe (MTL) seizure onsets and underwent MTL resection based on chronic ambulatory intracranial EEG (ICEEG) data from a direct brain-responsive neurostimulator (RNS) system. METHODS: We retrospectively identified all patients at 17 epilepsy centers with MTL epilepsy who were treated with the RNS System using bilateral MTL leads, and in whom an MTL resection was subsequently performed. Presumed lateralization based on routine presurgical approaches was compared to lateralization determined by RNS System chronic ambulatory ICEEG recordings. The primary outcome was frequency of disabling seizures at last 3-month follow-up after MTL resection compared to seizure frequency 3 months before MTL resection. RESULTS: We identified 157 patients treated with the RNS System with bilateral MTL leads due to presumed bitemporal epilepsy. Twenty-five patients (16%) subsequently had an MTL resection informed by chronic ambulatory ICEEG (mean = 42 months ICEEG); follow-up was available for 24 patients. After MTL resection, the median reduction in disabling seizures at last follow-up was 100% (mean: 94%; range: 50%-100%). Nine patients (38%) had exclusively unilateral electrographic seizures recorded by chronic ambulatory ICEEG and all were seizure-free at last follow-up after MTL resection; eight of nine continued RNS System treatment. Fifteen patients (62%) had bilateral MTL electrographic seizures, had an MTL resection on the more active side, continued RNS System treatment, and achieved a median clinical seizure reduction of 100% (mean: 90%; range: 50%-100%) at last follow-up, with eight of fifteen seizure-free. For those with more than 1 year of follow-up (N = 21), 15 patients (71%) were seizure-free during the most recent year, including all eight patients with unilateral onsets and 7 of 13 patients (54%) with bilateral onsets. SIGNIFICANCE: Chronic ambulatory ICEEG data provide information about lateralization of MTL seizures and can identify additional patients who may benefit from MTL resection.


Asunto(s)
Lobectomía Temporal Anterior/métodos , Epilepsia Refractaria/cirugía , Epilepsia del Lóbulo Temporal/cirugía , Lóbulo Temporal/cirugía , Adulto , Anciano , Epilepsia Refractaria/fisiopatología , Terapia por Estimulación Eléctrica , Electrocorticografía , Epilepsia del Lóbulo Temporal/fisiopatología , Femenino , Humanos , Neuroestimuladores Implantables , Masculino , Persona de Mediana Edad , Monitoreo Ambulatorio , Procedimientos Neuroquirúrgicos , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
3.
Epilepsia ; 58(6): 994-1004, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28398014

RESUMEN

OBJECTIVE: Evaluate the seizure-reduction response and safety of mesial temporal lobe (MTL) brain-responsive stimulation in adults with medically intractable partial-onset seizures of mesial temporal lobe origin. METHODS: Subjects with mesial temporal lobe epilepsy (MTLE) were identified from prospective clinical trials of a brain-responsive neurostimulator (RNS System, NeuroPace). The seizure reduction over years 2-6 postimplantation was calculated by assessing the seizure frequency compared to a preimplantation baseline. Safety was assessed based on reported adverse events. RESULTS: There were 111 subjects with MTLE; 72% of subjects had bilateral MTL onsets and 28% had unilateral onsets. Subjects had one to four leads placed; only two leads could be connected to the device. Seventy-six subjects had depth leads only, 29 had both depth and strip leads, and 6 had only strip leads. The mean follow-up was 6.1 ± (standard deviation) 2.2 years. The median percent seizure reduction was 70% (last observation carried forward). Twenty-nine percent of subjects experienced at least one seizure-free period of 6 months or longer, and 15% experienced at least one seizure-free period of 1 year or longer. There was no difference in seizure reduction in subjects with and without mesial temporal sclerosis (MTS), bilateral MTL onsets, prior resection, prior intracranial monitoring, and prior vagus nerve stimulation. In addition, seizure reduction was not dependent on the location of depth leads relative to the hippocampus. The most frequent serious device-related adverse event was soft tissue implant-site infection (overall rate, including events categorized as device-related, uncertain, or not device-related: 0.03 per implant year, which is not greater than with other neurostimulation devices). SIGNIFICANCE: Brain-responsive stimulation represents a safe and effective treatment option for patients with medically intractable epilepsy, including patients with unilateral or bilateral MTLE who are not candidates for temporal lobectomy or who have failed a prior MTL resection.


Asunto(s)
Encéfalo/fisiopatología , Estimulación Encefálica Profunda/métodos , Epilepsia Refractaria/fisiopatología , Epilepsia Refractaria/terapia , Terapia por Estimulación Eléctrica/métodos , Electroencefalografía , Epilepsias Parciales/fisiopatología , Epilepsias Parciales/terapia , Epilepsia del Lóbulo Temporal/fisiopatología , Epilepsia del Lóbulo Temporal/terapia , Adolescente , Adulto , Dominancia Cerebral/fisiología , Electrodos Implantados , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Cuidados a Largo Plazo , Masculino , Persona de Mediana Edad , Adulto Joven
4.
Epilepsia ; 58(6): 1005-1014, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28387951

RESUMEN

OBJECTIVE: Evaluate the seizure-reduction response and safety of brain-responsive stimulation in adults with medically intractable partial-onset seizures of neocortical origin. METHODS: Patients with partial seizures of neocortical origin were identified from prospective clinical trials of a brain-responsive neurostimulator (RNS System, NeuroPace). The seizure reduction over years 2-6 postimplantation was calculated by assessing the seizure frequency compared to a preimplantation baseline. Safety was assessed based on reported adverse events. Additional analyses considered safety and seizure reduction according to lobe and functional area (e.g., eloquent cortex) of seizure onset. RESULTS: There were 126 patients with seizures of neocortical onset. The average follow-up was 6.1 implant years. The median percent seizure reduction was 70% in patients with frontal and parietal seizure onsets, 58% in those with temporal neocortical onsets, and 51% in those with multilobar onsets (last observation carried forward [LOCF] analysis). Twenty-six percent of patients experienced at least one seizure-free period of 6 months or longer and 14% experienced at least one seizure-free period of 1 year or longer. Patients with lesions on magnetic resonance imaging (MRI; 77% reduction, LOCF) and those with normal MRI findings (45% reduction, LOCF) benefitted, although the treatment response was more robust in patients with an MRI lesion (p = 0.02, generalized estimating equation [GEE]). There were no differences in the seizure reduction in patients with and without prior epilepsy surgery or vagus nerve stimulation. Stimulation parameters used for treatment did not cause acute or chronic neurologic deficits, even in eloquent cortical areas. The rates of infection (0.017 per patient implant year) and perioperative hemorrhage (0.8%) were not greater than with other neurostimulation devices. SIGNIFICANCE: Brain-responsive stimulation represents a safe and effective treatment option for patients with medically intractable epilepsy, including adults with seizures of neocortical onset, and those with onsets from eloquent cortex.


Asunto(s)
Corteza Cerebral/fisiopatología , Estimulación Encefálica Profunda/métodos , Epilepsia Refractaria/fisiopatología , Epilepsia Refractaria/terapia , Terapia por Estimulación Eléctrica/métodos , Electroencefalografía , Neocórtex/fisiopatología , Adolescente , Adulto , Mapeo Encefálico , Estimulación Encefálica Profunda/instrumentación , Terapia por Estimulación Eléctrica/instrumentación , Electrodos Implantados , Epilepsias Parciales/fisiopatología , Epilepsias Parciales/terapia , Epilepsia Parcial Compleja/fisiopatología , Epilepsia Parcial Compleja/terapia , Epilepsia Parcial Motora/fisiopatología , Epilepsia Parcial Motora/terapia , Epilepsia Tónico-Clónica/fisiopatología , Epilepsia Tónico-Clónica/terapia , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
5.
Epilepsia ; 55(3): 432-41, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24621228

RESUMEN

OBJECTIVE: To demonstrate the safety and effectiveness of responsive stimulation at the seizure focus as an adjunctive therapy to reduce the frequency of seizures in adults with medically intractable partial onset seizures arising from one or two seizure foci. METHODS: Randomized multicenter double-blinded controlled trial of responsive focal cortical stimulation (RNS System). Subjects with medically intractable partial onset seizures from one or two foci were implanted, and 1 month postimplant were randomized 1:1 to active or sham stimulation. After the fifth postimplant month, all subjects received responsive stimulation in an open label period (OLP) to complete 2 years of postimplant follow-up. RESULTS: All 191 subjects were randomized. The percent change in seizures at the end of the blinded period was -37.9% in the active and -17.3% in the sham stimulation group (p = 0.012, Generalized Estimating Equations). The median percent reduction in seizures in the OLP was 44% at 1 year and 53% at 2 years, which represents a progressive and significant improvement with time (p < 0.0001). The serious adverse event rate was not different between subjects receiving active and sham stimulation. Adverse events were consistent with the known risks of an implanted medical device, seizures, and of other epilepsy treatments. There were no adverse effects on neuropsychological function or mood. SIGNIFICANCE: Responsive stimulation to the seizure focus reduced the frequency of partial-onset seizures acutely, showed improving seizure reduction over time, was well tolerated, and was acceptably safe. The RNS System provides an additional treatment option for patients with medically intractable partial-onset seizures.


Asunto(s)
Terapia por Estimulación Eléctrica/tendencias , Epilepsias Parciales/diagnóstico , Epilepsias Parciales/terapia , Neuroestimuladores Implantables/tendencias , Adolescente , Adulto , Anciano , Método Doble Ciego , Terapia por Estimulación Eléctrica/instrumentación , Terapia por Estimulación Eléctrica/métodos , Epilepsias Parciales/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Calidad de Vida/psicología , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
6.
Brain Stimul ; 6(5): 718-26, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23538208

RESUMEN

Long-term stability of the electrode-tissue interface may be required to maintain optimal neural recording with subdural and deep brain implants and to permit appropriate delivery of neuromodulation therapy. Although short-term changes in impedance at the electrode-tissue interface are known to occur, long-term changes in impedance have not previously been examined in detail in humans. To provide further information about short- and long-term impedance changes in chronically implanted electrodes, a dataset from 191 persons with medically intractable epilepsy participating in a trial of an investigational responsive neurostimulation device (the RNS(®) System, NeuroPace, Inc.) was reviewed. Monopolar impedance measurements were available for 391 depth and subdural leads containing a total of 1564 electrodes; measurements were available for median 802 days post-implant (range 28-1634). Although there were statistically significant short-term impedance changes, long-term impedance was stable after one year. Impedances for depth electrodes transiently increased during the third week after lead implantation and impedances for subdural electrodes increased over 12 weeks post-implant, then were stable over the subsequent long-term follow-up. Both depth and subdural electrode impedances demonstrated long-term stability, suggesting that the quality of long-term electrographic recordings (the data used to control responsive brain stimulation) can be maintained over time.


Asunto(s)
Encéfalo/fisiología , Impedancia Eléctrica , Terapia por Estimulación Eléctrica/métodos , Epilepsia/terapia , Neuroestimuladores Implantables , Método Doble Ciego , Terapia por Estimulación Eléctrica/instrumentación , Electrodos , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA