Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Am Heart Assoc ; 11(13): e025697, 2022 07 05.
Artículo en Inglés | MEDLINE | ID: mdl-35766315

RESUMEN

Background The association between alcohol consumption, atrial substrate, and outcomes after atrial fibrillation (AF) ablation remains controversial. This study evaluated the impacts of drinking on left atrial substrate and AF recurrence after ablation. Methods and Results We prospectively enrolled 110 patients with AF without structural heart disease (64±12 years) from 2 institutions. High-density left atrial electroanatomic mapping was performed using a high-density grid multipolar catheter. We investigated the impact of alcohol consumption on left atrial voltage, left atrial conduction velocity, and AF ablation outcome. Patients were classified as abstainers (<1 drink/wk), mild drinkers (1-7 drinks/wk), or moderate-heavy drinkers (>7 drinks/wk). High-density mapping (mean 2287±600 points/patient) was performed on 49 abstainers, 27 mild drinkers, and 34 moderate-heavy drinkers. Low-voltage zone and slow-conduction zone were identified in 39 (35%) and 54 (49%) patients, respectively. There was no significant difference in the proportions of low-voltage zone and slow-conduction zone among the 3 groups. The success rate after a single ablation was significantly lower in drinkers than in abstainers (79.3% versus 95.9% at 12 months; mean follow-up, 18±8 months; P=0.013). The success rate after a single or multiple ablations was not significantly different among abstainers and drinkers. In multivariate analysis, alcohol consumption (P=0.02) and the presence of a low-voltage zone (P=0.032) and slow-conduction zone (P=0.02) were associated with AF recurrence after a single ablation, while low-voltage zone (P=0.023) and slow-conduction zone (P=0.024) were associated with AF recurrence after a single or multiple ablations. Conclusions Alcohol consumption was associated with AF recurrence after a single ablation but not changes in atrial substrate.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Consumo de Bebidas Alcohólicas/efectos adversos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Atrios Cardíacos , Humanos , Recurrencia , Resultado del Tratamiento
2.
J Cardiovasc Electrophysiol ; 29(10): 1379-1387, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30016003

RESUMEN

BACKGROUND: Differential pacing technique to confirm mitral isthmus (MI) block is sometimes challenging due to destroyed tissues after extensive ablation. The purpose of this study is to set an endpoint of MI ablation using conduction time around the mitral annulus (MA). METHODS: Forty-five consecutive patients with persistent atrial fibrillation who received MI linear ablation were included. The geometry and activation times of the left atrium around the MA were collected using a multipolar catheter before ablation. During coronary sinus (CS) pacing, the time between the stimulus and the wave-front collision at the opposite side of the MA (defined as T/2) was calculated, and the doubled value was defined as the estimated perimitral conduction time (E-PMCT). The endpoint for complete MI block was when the stimulus (at distal CS) minus the maximal delayed potential (St-MDP) on the MI interval reached the E-PMCT. RESULTS: St-MDP reached E-PMCT during MI ablation in 44/45 patients. Among these 44 patients, differential pacing revealed bidirectional block in 39/44 (88.6%), whereas in 5/44 (11.4%), the differential pacing was not possible because of the loss of capture of local potentials due to extensive applications around the linear line. In one patient, the St-MDP did not reach E-PMCT (E-PMCT: 148 ms, St-MDP :130 ms) and differential pacing revealed no MI block. E-PMCT values (median 176 ms) correlated strongly with St-MDP (median 185 ms, P < 0.0001, R = 0.98). CONCLUSIONS: Although E-PMCT differs between individuals, the value is significantly correlated with the St-MDP. This technique may be useful in providing an individual endpoint of MI ablation as an alternative to differential pacing.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial/cirugía , Estimulación Cardíaca Artificial , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Válvula Mitral/cirugía , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/fisiopatología , Valor Predictivo de las Pruebas , Venas Pulmonares/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA