Artículo en Inglés | MEDLINE | ID: mdl-36281981

RESUMEN

The goal of this study was to assess the efficiency of antibiotic degradation applying different chemical treatment methods and their combinations. Thus, improvement in the efficiency of these methods when combined was quantified. The methods tested to degrade/mineralize the antibiotics amoxicillin (AMX) and ciprofloxacin (CIP) under different pH conditions (4, 7 and 10) were ultra-violet irradiation (UV254 nm), ultrasound (US), hydrogen peroxide (H2O2) and ozone (O3) alone and in combination. The results showed that individual methods were only partially efficient in the degradation/mineralization of antibiotics, except for ozonation at alkaline pH. In the combined methods, the best performance was obtained with US/UV/H2O2/O3 (pH 10, 20-min treatment), where the degradation rates for the antibiotics were 99.8% for CIP and 99.9% for AMX. For the mineralization efficiency the values obtained were 71.3% for CIP and 79.2% for AMX. The results of this study could contribute to the development and improvement of wastewater treatment aimed at avoiding the presence of residual antibiotics in the environment.


Asunto(s)
Ozono , Contaminantes Químicos del Agua , Purificación del Agua , Peróxido de Hidrógeno/química , Contaminantes Químicos del Agua/análisis , Oxidación-Reducción , Amoxicilina , Ciprofloxacina/química , Antibacterianos/química
2.
Environ Sci Pollut Res Int ; 28(13): 16532-16543, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33387324

RESUMEN

The degradation efficiency of the Fenton reaction or ozonolysis (O3) to treat soil contaminated by crude petroleum was studied in association with the sonolysis process. To quantify oxidation efficiency, total organic carbon (TOC) and chemical oxygen demand (COD) were measured, while biochemical oxygen demand (BOD5) was measured to estimate biodegradation potential. TOC removal efficiency ranged from 9 to 52% to the Fenton reaction without sonolysis, and 18% and 78% with sonolysis for reagent concentrations of 1% H2O2-100 mM Fe2+ and 20% H2O2-1 mM Fe2+, respectively. For ozonolysis (after 10 and 60 min of treatment), the reduction in TOC ranged from 9 to 43% without sonolysis and 15 to 61% with sonolysis. The Fenton reaction without sonolysis increased the biodegradability in relation to the non-oxidized sample by 6% (1% H2O2-100 mM Fe2+) and 26% (20% H2O2-1 mM Fe2+), and with sonolysis the corresponding values were 13% and 42%, respectively. The biodegradation potential under ozonolysis without sonolysis increased from 0.18 (10 min of treatment) to 0.38 (30 min of treatment), and with sonolysis these values were 0.26 and 0.58, respectively. Optimization of the remediation processes is essential to determine sequential treatment order and efficiency.


Asunto(s)
Ozono , Petróleo , Contaminantes Químicos del Agua , Peróxido de Hidrógeno , Hierro , Oxidación-Reducción , Suelo , Contaminantes Químicos del Agua/análisis