Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Circ Arrhythm Electrophysiol ; 9(2): e003706, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26850881

RESUMEN

BACKGROUND: We sought to evaluate the safety and feasibility of a minimally fluoroscopic approach using the CARTOUNIVU module during scar-related ventricular tachycardia (VT) ablation. METHODS AND RESULTS: Consecutive patients with structural heart disease undergoing VT ablation using the CARTOUNIVU module were prospectively included and classified depending on their VT substrate: (1) ischemic VT (IVT) and (2) nonischemic VT and depending on the presence of an epicardial access. Radiation exposure parameters and major and minor procedure-related complications were registered. A near-zero fluoroscopy exposure was defined as those procedures with an effective dose ≤1 mSv. A total of 44 VT ablation procedures were performed in 41 patients (22 IVT and 19 nonischemic VT). The use of the CARTOUNIVU module resulted in low levels of radiation exposure: median total fluoroscopy time and effective dose of 6.08 (1.51-12.36) minutes and 2.15 (0.58-8.22) mSv, respectively. Patients with IVT had lower radiation exposure than patients with nonischemic VT (total fluoroscopy time, 2.53 [1.22-11.22] versus 8.51 [5.55-17.34] minutes; P=0.016). Epicardial access was associated with significantly higher levels of radiation exposure. Complications occurred in 4.9% patients, none of them being related to the use of the image integration tool. A near-zero fluoroscopy ablation could be performed in 14 of 44 procedures (32%), 43% of IVT procedures, and 50% of procedures with endocardial access only. CONCLUSIONS: The use of the CARTOUNIVU module during scar-related VT ablation resulted in low levels of radiation exposure. A near-zero fluoroscopy approach can be achieved in up to half of the procedures, especially in IVT patients with endocardial ablation.


Asunto(s)
Ablación por Catéter/métodos , Sistema de Conducción Cardíaco/cirugía , Cardiopatías/complicaciones , Radiografía Intervencional/métodos , Taquicardia Ventricular/cirugía , Potenciales de Acción , Anciano , Ablación por Catéter/efectos adversos , Técnicas Electrofisiológicas Cardíacas , Estudios de Factibilidad , Femenino , Fluoroscopía , Sistema de Conducción Cardíaco/fisiopatología , Cardiopatías/diagnóstico , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Estudios Prospectivos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Radiografía Intervencional/efectos adversos , Factores de Riesgo , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
5.
Pacing Clin Electrophysiol ; 31(6): 709-13, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18507543

RESUMEN

BACKGROUND: Several studies showed the beneficial effect of pacemaker implantation on cognitive performance in patients with bradycardia. But it has never been investigated if patients with chronotropic incompetence may improve their cognitive performance if treated by a rate-adaptive system reacting to mental stress in comparison to the most frequently used accelerometer-driven pacing. METHODS: The randomized, single-blind, multicenter COGNITION study evaluates if closed loop stimulation (CLS) offers incremental benefit in the speed of cognitive performance and the overall well-being of elderly patients with bradycardia compared with accelerometer-based pacing. Four hundred chronotropically incompetent patients older than 55 years will be randomized 3-6 weeks after implantation to CLS or accelerometer sensor. Follow-up visits are performed after 12 and 24 months. The speed of cognitive performance, which is the underlying function influencing all other aspects of cognitive performance, will be assessed by the number connection test, a standardized psychometric test for the elderly. Secondary endpoints include patient self-assessment of different aspects of health (by visual analogue scales), quality of life (by SF-8 health survey), the incidence of atrial fibrillation (episodes lasting for longer than 24 hours), and the frequency of serious adverse events. CONCLUSION: In the ongoing COGNITION study, we aim at long-term comparison of two rate-adaptive systems, focusing on the cognitive performance of the patients, which was neglected in the past evaluation of pacemaker sensors.


Asunto(s)
Fibrilación Atrial/prevención & control , Biorretroalimentación Psicológica/métodos , Trastornos del Conocimiento/prevención & control , Trastornos del Conocimiento/psicología , Marcapaso Artificial/psicología , Marcapaso Artificial/estadística & datos numéricos , Ensayos Clínicos Controlados Aleatorios como Asunto , Fibrilación Atrial/psicología , Alemania/epidemiología , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA