Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Glob Pediatr Health ; 11: 2333794X241240574, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38577660

RESUMEN

Objectives. To evaluate the interaction between childhood asthma and S. 25(OH) cholecalciferol among Bangladeshi children. Methods. This case control study was conducted in child asthma clinic, Bangladesh Shishu Hospital Institute during March-August 2021. Comparison was made between clinically-diagnosed (following GINA guideline) asthmatic children (2-12 years-old) (cases = 87) and age and sex-matched children having no respiratory illness (controls = 90) using SPSS' (Statistical Package for Social Science, V.23.0 Windows) software. Results. Serum 25(OH) cholecalciferol was found to be significantly lower among the cases than the controls (P < .01). The cases had 3.4 times higher likelihood of having low vitamin D (combined deficient + insufficient) than the controls (P < .01). Conclusions. The results of the study demonstrate an association of Serum 25 (OH) cholecalciferol with asthma which underscores the importance of potential future trial to evaluate the efficacy of Vitamin-D supplementation for understanding the outcomes of asthmatic Bangladeshi children.

2.
IEEE J Biomed Health Inform ; 23(6): 2347-2353, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-30640639

RESUMEN

OBJECTIVE: Careful screening of bilirubin level in newborns is mandatory as per American Academy of Pediatrics (2004), to reduce incidents of kernicterus and acute bilirubin encephalopathy. Although, invasive capillary collection of blood and subsequent biochemical test is considered a gold standard for jaundice detection in neonates, transcutaneous bilirubin measurement using various non-invasive instruments is also used sporadically across the globe. The major aim of this study was to develop a non-invasive spectrometry-based technique for measurement of neonatal bilirubin level as an alternative of total serum bilirubin (TSB) test without limitations of other available bilirubinometers. METHODS: The instrument comprises of a light source and a spectroscopic detector. A light beam from source incident on the neonatal nail plate through optical fibers. The retro reflected light is acquired using the detector. An indigenously developed software is used to acquire and analyze the optical signal and to calculate the bilirubin value. The instrument was calibrated and validated in reference to TSB on 1033 subjects. MAJOR RESULTS: The result (r = 0.95 and P < 0.001) indicates a strong correlation between the bilirubin value obtained from our method and TSB. Time variant analysis of the subjects undergoing phototherapy provided a good correlation (r = 0.98). The repeatability test result shows the mean coefficient of variation is less than 5.0%. CONCLUSIONS: The indigenously developed non-invasive technique successfully detects the bilirubin level in newborns under various physiological conditions with high accuracy and precision.


Asunto(s)
Bilirrubina/sangre , Hiperbilirrubinemia Neonatal/diagnóstico , Procesamiento de Señales Asistido por Computador/instrumentación , Análisis Espectral/métodos , Diseño de Equipo , Humanos , Recién Nacido , Uñas/irrigación sanguínea , Análisis Espectral/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA