Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Cardiovasc Med (Hagerstown) ; 22(10): 751-758, 2021 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-34009182

RESUMEN

AIMS: Radiation use in medicine has significantly increased over the last decade, and cardiologists are among the specialists most responsible for X-ray exposure. The present study investigates a broad range of aspects, from specific European Union directives to general practical principles, related to radiation management among a national cohort of cardiologists. METHODS AND RESULTS: A voluntary 31-question survey was run on the Italian Arrhythmology and Pacing Society (AIAC) website. From June 2019 to January 2020, 125 cardiologists, routinely performing interventional electrophysiology, participated in the survey. Eighty-seven (70.2%) participants are aware of the recent European Directive (Euratom 2013/59), although only 35 (28.2%) declare to have read the document in detail. Ninety-six (77.4%) participants register the dose delivered to the patient in each procedure, in 66.1% of the cases both as fluoroscopy time and dose area product. Years of exposition (P = 0.009) and working in centers performing pediatric procedures (P = 0.021) related to greater degree of X-ray equipment optimization. The majority of participants (72, 58.1%) did not recently attend radioprotection courses. The latter is related to increased awareness of techniques to reduce radiation exposure (96% vs. 81%, P = 0.022), registration of the delivered dose in each procedure (92% vs. 67%, P = 0.009), and X-ray equipment optimization (50% vs. 36%, P = 0.006). CONCLUSION: Italian interventional cardiologists show an acceptable level of radiation awareness and knowledge of updated European directives. However, there is clear space for improvement. Comparison to other health professionals, both at national and international levels, is needed to pursue proper X-ray management and protect public health.


Asunto(s)
Técnicas Electrofisiológicas Cardíacas , Exposición Profesional , Exposición a la Radiación , Administración de la Seguridad , Electrofisiología Cardíaca/normas , Cardiología/normas , Técnicas Electrofisiológicas Cardíacas/efectos adversos , Técnicas Electrofisiológicas Cardíacas/métodos , Técnicas Electrofisiológicas Cardíacas/normas , Conocimientos, Actitudes y Práctica en Salud , Humanos , Italia , Exposición Profesional/análisis , Exposición Profesional/prevención & control , Exposición Profesional/estadística & datos numéricos , Exposición a la Radiación/análisis , Exposición a la Radiación/prevención & control , Exposición a la Radiación/estadística & datos numéricos , Administración de la Seguridad/métodos , Administración de la Seguridad/organización & administración , Encuestas y Cuestionarios
2.
J Cardiovasc Med (Hagerstown) ; 21(4): 292-298, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32068573

RESUMEN

INTRODUCTION: Atrial fibrillation ablation has historically been guided by fluoroscopy, with the related enhanced risk deriving from radiation. Fluoroscopy exposure may be confined to guide the transseptal puncture. Small sample size study presented a new methodology to perform a totally fluoroless atrial fibrillation ablation in the case of a patent foramen ovale (PFO). We evaluated this methodology in a large sample size of patients and a multicentre experience. METHODS AND RESULTS: Two hundred and fifty paroxysmal atrial fibrillation patients referred for first atrial fibrillation ablation with a CARTO3 electroanatomic mapping system were enrolled. In 58 out of 250 patients, a PFO allowed crossing of the interatrial septum, and a completely fluoroless ablation was performed applying the new method (Group A). In the remaining patients, a standard transseptal puncture was performed (Group B). Pulmonary vein isolation was achieved in all patients with comparable procedural and clinical outcomes at short- and long-term follow-up. CONCLUSION: The presence of a PFO may allow a completely fluoroless well tolerated and effective atrial fibrillation ablation. Probing the fossa ovalis looking for the PFO during the procedure is desirable, as it is not time-consuming and can potentially be done in every patient undergoing atrial fibrillation ablation.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial/cirugía , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Foramen Oval Permeable , Venas Pulmonares/cirugía , Cirugía Asistida por Computador , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Femenino , Foramen Oval Permeable/diagnóstico por imagen , Frecuencia Cardíaca , Humanos , Italia , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Cirugía Asistida por Computador/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
3.
J Cardiovasc Med (Hagerstown) ; 21(2): 113-122, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31895131

RESUMEN

AIMS: We evaluated the ability of an ultrahigh mapping system to identify the most convenient Rhythmia ablation target (RAT) in intra-atrial re-entrant tachycardias (IART) in terms of the narrowest area to transect to interrupt the re-entry. METHODS: A total of 24 consecutive patients were enrolled with a total of 26 IARTs. The Rhythmia mapping system was used to identify the RAT in all IARTs. RESULTS: In 18 cases the RAT matched the mid-diastolic phase of the re-entry whereas in 8 cases the RAT differed. In these patients, the mid-diastolic tissue in the active circuit never represented the area with the slowest conduction velocity of the re-entry. The mean conduction velocity at the mid-diastolic site was significantly slower in the group of patients in which the RAT matched the mid-diastolic site (P = 0.0173) and that of the remaining circuit was significantly slower in the group in which the RAT did not match (P = 0.0068). The mean conduction velocity at the RAT was comparable between the two groups (P = 0.66). CONCLUSION: Identifying the RAT in challenging IARTs by means of high-density representation of the wavefront propagation of the tachycardia seems feasible and effective. In one-third of cases this approach identifies an area that differs from the mid-diastolic corridor.


Asunto(s)
Potenciales de Acción , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Frecuencia Cardíaca , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirugía , Ablación por Catéter/efectos adversos , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , España , Taquicardia Supraventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
4.
JACC Cardiovasc Interv ; 10(9): 879-888, 2017 05 08.
Artículo en Inglés | MEDLINE | ID: mdl-28473110

RESUMEN

OBJECTIVES: This study sought to evaluate the incidence and clinical effect of coronary chronic total occlusions (CTOs) in patients with ischemic cardiomyopathy receiving an implantable cardioverter-defibrillator (ICD) for secondary prevention of sudden cardiac death (SCD). BACKGROUND: CTOs are common in patients with ischemic cardiomyopathy, which is the major cause of SCD. However, the impact of CTO in SCD survivors receiving an ICD is unknown. METHODS: A total of 425 patients who had survived an episode of ventricular arrhythmias and underwent ICD implantation for secondary prevention in 8 centers were included. Coronary angiogram, CTO angiographic characteristics, and ventricular arrhythmia pattern were centrally analyzed. Primary and secondary endpoints were appropriate ICD therapies and mortality during a median follow-up of 4.1 years, according to the presence of CTO in the baseline angiogram. RESULTS: Appropriate ICD therapies were higher in patients with CTO (51.7% vs. 36.3%; p = 0.001 at 4 years). Left ventricular ejection fraction (LVEF) (p = 0.015) and CTO (p = 0.001) were independent predictors of appropriate ICD therapy. Ventricular arrhythmia onset was associated to a shorter coupling interval and lower prematurity index in CTO patients. Defibrillator therapies were independently associated with worse LVEF (p = 0.046) and renal dysfunction (p = 0.023) among patients with CTO, and a tendency was observed in patients with better collateral flow (p = 0.093). Patients with poorer renal function (p = 0.029), LVEF (p = 0.041), and CTO (p = 0.033) experienced higher mortality rate. CONCLUSIONS: Among ICD recipients for secondary prevention of SCD, coronary CTO conferred a higher risk of VA recurrence and mortality in long-term follow-up. Angiographic and VA patterns could provide insights into the mechanisms of SCD and may have implications for the use of interventions designed to limit ICD shocks in this high-risk population.


Asunto(s)
Arritmias Cardíacas/terapia , Angiografía Coronaria , Oclusión Coronaria/diagnóstico por imagen , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Técnicas Electrofisiológicas Cardíacas , Prevención Secundaria/instrumentación , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Enfermedad Crónica , Oclusión Coronaria/mortalidad , Muerte Súbita Cardíaca/etiología , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Europa (Continente)/epidemiología , Femenino , Humanos , Incidencia , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Modelos de Riesgos Proporcionales , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
5.
J Cardiovasc Electrophysiol ; 16(10): 1071-6, 2005 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16191117

RESUMEN

INTRODUCTION: The complexity of waveforms during atrial fibrillation may reflect critical activation patterns for the arrhythmia perpetuation. In this study, we introduce a novel concept of map, based on the analysis of the wave morphology, which gives a direct evidence in the human right atrium on the spatiotemporal distribution of fibrillatory wave complexity in paroxysmal (PAF) and chronic (CAF) atrial fibrillation. METHODS AND RESULTS: Electrograms were recorded from a 64-electrode catheter in the right atrium of 15 patients during PAF (n = 8) and CAF (n = 7). Wave similarity maps were constructed by calculating the degree of morphological similarity of activation waves (S) at each atrial site and by following its temporal evolution. During PAF the spatiotemporal distribution of the waveforms was highly consistent across the subjects and was determined by the anatomic location. Wave similarity maps showed the existence of an extended area with low similarity index, which covered the low posteroseptal atrium (S = 0.28 +/- 0.09) and the septal region (S = 0.22 +/- 0.04), and the presence of a large tongue with high similarity index, which penetrated the lateral wall (S = 0.55 +/- 0.08) starting from the high anterolateral atrium (S = 0.54 +/- 0.06). A completely different spatiotemporal pattern was seen during CAF. No distinct regions with different similarity indexes were recognized, but a uniformly distributed low similarity index (S = 0.27 +/- 0.07) was found. The spatial pattern was highly stable in time with fluctuations of S < 0.04. CONCLUSION: Quantification of the spatiotemporal distribution of fibrillatory wave complexity is feasible in humans by wave similarity mapping. Anatomic anchoring of waveforms during PAF and pattern destruction during CAF was determined.


Asunto(s)
Fibrilación Atrial/fisiopatología , Mapeo del Potencial de Superficie Corporal , Sistema de Conducción Cardíaco/fisiopatología , Adulto , Mapeo del Potencial de Superficie Corporal/métodos , Enfermedad Crónica , Técnicas Electrofisiológicas Cardíacas , Femenino , Atrios Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad
6.
Ital Heart J ; 3(4): 263-9, 2002 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-12025376

RESUMEN

BACKGROUND: This study investigated whether a minimal approach to typical atrial flutter ablation using an 8 mm tip catheter with a 150 W generator with only the documentation of clockwise block by means of local criteria predicts a good long-term outcome. METHODS: Seventy patients underwent typical atrial flutter ablation. A multipolar catheter was inserted into the coronary sinus (CS) and an 8 mm tip ablation catheter was used to ablate and map the isthmus. The ablation line was performed in the posteroseptal region. The clockwise block was confirmed by recording a corridor of double potentials along the line and by counterclockwise activation of the portion of the isthmus just beyond the lesion line as demonstrated by measuring the conduction times during CS pacing. RESULTS: In case of block, the mean distance between the two split atrial electrograms was 129 +/- 31 ms. Acute isthmus block was achieved in all 70 patients. The median of the radiofrequency pulses was 10 (range 1-36). No immediate or late complications were noted. The long-term follow-up (19.5 +/- 4 months) revealed recurrence of typical atrial flutter in 2 cases (2.8%). CONCLUSIONS: Our results demonstrate that the acute success rate following typical atrial flutter isthmus ablation using an 8 mm tip catheter with a 150 W generator is high. No complications occurred. Moreover, the documentation of just the clockwise isthmus block using a minimal approach according to local electrogram criteria is a good predictor of the long-term success.


Asunto(s)
Aleteo Atrial/cirugía , Ablación por Catéter , Electrocardiografía , Aleteo Atrial/fisiopatología , Técnicas Electrofisiológicas Cardíacas , Femenino , Sistema de Conducción Cardíaco/cirugía , Humanos , Masculino , Persona de Mediana Edad , Válvula Tricúspide , Vena Cava Inferior
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA