Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37428890

RESUMEN

AIMS: Although the mechanism of an atrial tachycardia (AT) can usually be elucidated using modern high-resolution mapping systems, it would be helpful if the AT mechanism and circuit could be predicted before initiating mapping. OBJECTIVE: We examined if the information gathered from the cycle length (CL) of the tachycardia can help predict the AT-mechanism and its localization. METHODS: One hundred and thirty-eight activation maps of ATs including eight focal-ATs, 94 macroreentrant-ATs, and 36 localized-ATs in 95 patients were retrospectively reviewed. Maximal CL (MCL) and minimal CL (mCL) over a minute period were measured via a decapolar catheter in the coronary sinus. CL-variation and beat-by-beat CL-alternation were examined. Additionally, the CL-respiration correlation was analysed by the RhythmiaTM system. : Both MCL and mCL were significantly shorter in macroreentrant-ATs [MCL = 288 (253-348) ms, P = 0.0001; mCL = 283 (243-341) ms, P = 0.0012], and also shorter in localized-ATs [MCL = 314 (261-349) ms, P = 0.0016; mCL = 295 (248-340) ms, P = 0.0047] compared to focal-ATs [MCL = 506 (421-555) ms, mCL = 427 (347-508) ms]. An absolute CL-variation (MCL-mCL) < 24 ms significantly differentiated re-entrant ATs from focal-ATs with a sensitivity = 96.9%, specificity = 100%, positive predictive value (PPV) = 100%, and negative predictive value (NPV) = 66.7%. The beat-by-beat CL-alternation was observed in 10/138 (7.2%), all of which showed the re-entrant mechanism, meaning that beat-by-beat CL-alternation was the strong sign of re-entrant mechanism (PPV = 100%). Although the CL-respiration correlation was observed in 28/138 (20.3%) of ATs, this was predominantly in right-atrium (RA)-ATs (24/41, 85.7%), rather than left atrium (LA)-ATs (4/97, 4.1%). A positive CL-respiration correlation highly predicted RA-ATs (PPV = 85.7%), and negative CL-respiration correlation probably suggested LA-ATs (NPV = 84.5%). CONCLUSION: Detailed analysis of the tachycardia CL helps predict the AT-mechanism and the active AT chamber before an initial mapping.


Asunto(s)
Ablación por Catéter , Taquicardia Supraventricular , Humanos , Estudios Retrospectivos , Técnicas Electrofisiológicas Cardíacas , Taquicardia , Atrios Cardíacos , Resultado del Tratamiento
2.
J Cardiovasc Electrophysiol ; 30(4): 528-537, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30656771

RESUMEN

INTRODUCTION: Adenosine triphosphate (ATP) sensitive atrial tachycardia (AT) has been treated by radiofrequency catheter ablation. Cryofreezing energy has emerged as a novel energy source for catheter ablation. The aim of this study was to investigate the efficacy and safety of cryofreezing ablation for ATP-sensitive AT. METHODS AND RESULTS: A total of six patients with ATP-sensitive ATs were included in this study. A single atrial extrastimulation was able to initiate and terminate these ATs in all six patients. The electrophysiological findings satisfied the diagnostic criteria of ATP-sensitive AT. The ablation catheter was located at the earliest activation site of atrial excitation during the AT, and cryofreezing energy was delivered through a cryoablation catheter to perform cryomapping at temperature of -30 or -80°C. When cryomapping successfully terminated the ATs, cryoablation at a temperature of -80°C was subsequently performed. The earliest atrial activation during AT was recorded at the Koch's triangle area associated with a distinct intra-atrial activation sequence from that recorded during ventricular pacing. Cryoablation was performed at successful cryomapping sites and resulted in the complete elimination of the AT in all six patients without affecting the bidirectional atrioventricular (AV) nodal conduction. CONCLUSION: Cryofreezing energy was safe and effective in treating ATP-sensitive ATs even in patients with its origins located in the vicinity of the AV node.


Asunto(s)
Adenosina Trifosfato/administración & dosificación , Criocirugía , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Taquicardia Supraventricular/cirugía , Potenciales de Acción , Adulto , Anciano , Criocirugía/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA