Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Open Heart ; 7(2)2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32690548

RESUMEN

INTRODUCTION: Patient evaluation before cardiac resynchronisation therapy (CRT) remains heterogeneous across centres and it is suspected a proportion of patients with unfavourable characteristics proceed to implantation. We developed a unique CRT preassessment clinic (CRT PAC) to act as a final review for patients already considered for CRT. We hypothesised that this clinic would identify some patients unsuitable for CRT through updated investigations and review. The purpose of this analysis was to determine whether the CRT PAC led to savings for the National Health Service (NHS). METHODS: A decision tree model was made to evaluate two clinical pathways; (1) standard of care where all patients initially seen in an outpatient cardiology clinic proceeded directly to CRT and (2) management of patients in CRT PAC. RESULTS: 244 patients were reviewed in the CRT PAC; 184 patients were eligible to proceed directly for implantation and 48 patients did not meet consensus guidelines for CRT so were not implanted. Following CRT, 82.4% of patients had improvement in their clinical composite score and 57.7% had reduction in left ventricular end-systolic volume ≥15%. Using the decision tree model, by reviewing patients in the CRT PAC, the total savings for the NHS was £966 880. Taking into consideration the additional cost of the clinic and by applying this model structure throughout the NHS, the potential savings could be as much as £39 million. CONCLUSIONS: CRT PAC appropriately selects patients and leads to substantial savings for the NHS. Adopting this clinic across the NHS has the potential to save £39 million.


Asunto(s)
Terapia de Resincronización Cardíaca/economía , Toma de Decisiones Clínicas , Prestación Integrada de Atención de Salud/economía , Costos de la Atención en Salud , Cardiopatías/economía , Cardiopatías/terapia , Servicio Ambulatorio en Hospital/economía , Selección de Paciente , Medicina Estatal/economía , Anciano , Anciano de 80 o más Años , Terapia de Resincronización Cardíaca/efectos adversos , Ahorro de Costo , Análisis Costo-Beneficio , Técnicas de Apoyo para la Decisión , Árboles de Decisión , Prestación Integrada de Atención de Salud/organización & administración , Femenino , Cardiopatías/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Modelos Económicos , Servicio Ambulatorio en Hospital/organización & administración , Evaluación de Programas y Proyectos de Salud , Derivación y Consulta/economía , Medicina Estatal/organización & administración , Reino Unido
2.
Heart Rhythm ; 16(5): 702-709, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30528448

RESUMEN

BACKGROUND: Enhanced beat-to-beat variability of repolarization is strongly linked to arrhythmogenesis and is largely due to variation in ventricular action potential duration (APD). Previous studies in humans have relied on QT interval measurements; however, a direct relationship between beat-to-beat variability of APD and arrhythmogenesis in humans has yet to be demonstrated. OBJECTIVE: This study aimed to explore the beat-to-beat repolarization dynamics in patients with heart failure at the level of ventricular APD. METHODS: Forty-three patients with heart failure and implanted cardiac resynchronization therapy - defibrillator devices were studied. Activation-recovery intervals as a surrogate for APD were recorded from the left ventricular epicardial lead while pacing from the right ventricular lead to maintain a constant cycle length. RESULTS: During a mean follow-up of 23.6±13.6 months, 11 patients sustained ventricular fibrillation/ventricular tachycardia (VT/VF) and received appropriate implantable cardioverter-defibrillator therapies (antitachycardia pacing or shock therapy). Activation-recovery interval variability (ARIV) was significantly greater in patients with subsequent VT/VF than in those without VT/VF (3.55±1.3 ms vs 2.77±1.09 ms; P=.047). Receiver operating characteristic curve analysis (area under the curve 0.71; P=.046) suggested high- and low-risk ARIV groups for VT/VF. Kaplan-Meier survival analysis demonstrated that the time until first appropriate therapy for VT/VF was significantly shorter in the high-risk ARIV group (P=.028). ARIV was a predictor for VT/VF in the multivariate Cox model (hazard ratio 1.623; 95% confidence interval 1.1-2.393; P=.015). CONCLUSION: Increased left ventricular ARIV is associated with an increased risk of VT/VF in patients with heart failure.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Sistema de Conducción Cardíaco/fisiopatología , Insuficiencia Cardíaca , Ventrículos Cardíacos/fisiopatología , Taquicardia Ventricular , Análisis de Varianza , Desfibriladores Implantables , Femenino , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Factores de Riesgo , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA