Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Pharm Biomed Anal ; 207: 114398, 2022 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-34626939

RESUMEN

Natural sweeteners are in high demand as a part of a healthy lifestyle. Among them, sweeteners with decreased caloric value and suitability for diabetes patients are most requested. Extension in their consumption extends the need for their quality control. A fast gradient UHPLC coupled with charged aerosol detection enabling quantitation of stevioside, rebaudioside A-D, and steviolbioside in commercial sweeteners and Stevia rebaudiana plant extracts has been developed. The method was developed to achieve high efficiency, simplicity, versatility, and low solvent consumption. All steviol glycosides were baseline-separated in less than 4 min with a total run time of 7 min. Buffer-free eluents were used in the separations and only 2.45 mL solvent were needed per analysis. The Luna Omega Polar column featuring polar modification of the C18 stationary phase was employed with mobile phases composed of water and acetonitrile for the excellent separation of polar steviol glycosides. The flow rate of the mobile phase 0.35 mL/min, column temperature 50 °C and injection volume 2 µL were used. Critical pair of glycosides, stevioside and rebaudioside A, were baseline separated with a resolution of 2.41. The universal charged aerosol detector allowed quantitation of steviol glycosides with a limit of detection and quantitation 0.15 and 0.5 µg/mL, respectively. Method intra-day precision was less than 2% (RSD), and the recovery was 89.6-105.0% and 93.8-111.4% for plant material and sweetener tablets, respectively. The quantity of steviol glycosides in three out of four commercial sweeteners was 3.0-12.3% higher than declared. The content was about 12.4% less than declared in one sample. But the difference from the labeled content corresponded to trueness and precision of the developed method together with variability of sweeteners production. The most abundant glycoside detected in sweeteners was stevioside followed by rebaudioside A. A leaf-to-stem ratio describing the dominant accumulation of steviol glycosides in leaves affected the differences in the amount of steviol glycosides among plant samples.


Asunto(s)
Diterpenos de Tipo Kaurano , Stevia , Aerosoles , Cromatografía Líquida de Alta Presión , Diterpenos de Tipo Kaurano/análisis , Glucósidos , Glicósidos , Humanos , Extractos Vegetales , Hojas de la Planta/química , Edulcorantes/análisis
2.
Anal Bioanal Chem ; 411(6): 1219-1228, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30617392

RESUMEN

A fully automated method for the determination of lovastatin in dietary supplements containing red yeast rice has been developed. It uses a sequential injection analysis system combined with solid-phase extraction applying highly selective molecularly imprinted polymer sorbent. A miniaturized column for on-line extraction was prepared by packing 4.5 mg of the sorbent in a 5.0 × 2.5-mm-i.d. cartridge, which was used in the flow manifold. Sequential injection analysis manifold enabled all steps of lovastatin extraction and continuous spectrophotometric detection at 240 nm. A limit of detection of 60 µg g-1, a limit of quantitation of 200 µg g-1, and a linear calibration range of 200-2000 µg g-1 were achieved. Intra-day and inter-day precision values (RSD) were ≤ 6.7% and ≤ 4.9%, respectively, and method recovery values of spiked red yeast rice extracts at 200, 1000, and 2000 µg g-1 concentration levels were 82.9, 95.2, and 87.7%. Our method was used for determination of lovastatin lactone in four dietary supplements containing red yeast rice as a natural source of lovastatin, also known as monacolin K. The extracted samples were subsequently analyzed by the reference UHPLC-MS/MS method. Statistical comparison of results (F test, t test, α = 0.05) obtained by both methods did not reveal significant difference. A substantial advantage of the new automated approach is high sample throughput thanks to the analysis time of 7.5 min, miniaturization via down-scaling the extraction column, and smaller sample and solvent consumption, as well as reduced generation of waste. Graphical abstract ᅟ.


Asunto(s)
Anticolesterolemiantes/análisis , Productos Biológicos/análisis , Suplementos Dietéticos/análisis , Lovastatina/análisis , Impresión Molecular/métodos , Extracción en Fase Sólida/métodos , Cromatografía Líquida de Alta Presión/instrumentación , Cromatografía Líquida de Alta Presión/métodos , Diseño de Equipo , Análisis de Inyección de Flujo/instrumentación , Análisis de Inyección de Flujo/métodos , Límite de Detección , Impresión Molecular/instrumentación , Polímeros/química , Extracción en Fase Sólida/instrumentación , Espectrofotometría Ultravioleta/instrumentación , Espectrofotometría Ultravioleta/métodos , Espectrometría de Masas en Tándem/instrumentación , Espectrometría de Masas en Tándem/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA