Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Heart Rhythm ; 16(10): 1523-1530, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31048064

RESUMEN

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) has established its role in the prevention of sudden cardiac death in a defined population. Inappropriate shocks and device malfunction in S-ICD therapy may be caused by myopotential (MP) oversensing. OBJECTIVE: The purpose of this study was to systematically evaluate a cohort of consecutive S-ICD patients for MP inducibility. METHODS: After S-ICD implantation, all vectors (primary [PrimV], secondary [SecV], alternative [AltV]) were analyzed during isometric chest press (ICP), lifting and holding a 20-kg weight, and side plank exercise (SPE), supporting the body weight on the left arm. When MPs were induced, signal classification was assessed: adequate noise detection, induced undersensing (R waves classified as noise), and oversensing (noise annotated as R waves). In case of noise induction in the current vector, device reprogramming to a noise-free vector was done. RESULTS: We systematically assessed 41 patients. In nearly all patients (90.2%), MPs were inducible. ICP was the most potent inductor of MPs. Whereas SecV (70.7%) and AltV (75.6%) were most vulnerable during ICP, PrimV was most affected during SPE (51.2%). In only a few cases did the S-ICD software distinguish correctly between MPs and QRS. MPs predominantly led to undersensing (up to 65.9%), but in up to 22% of patients MP-induced oversensing occurred but did not lead to tachycardia detection. No relation was seen between S-ICD lead and generator position and MP inducibility. CONCLUSION: Induction of MPs during physical exercise was observed frequently. Although in most cases MP noise led to undersensing, oversensing events were commonly observed.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Prueba de Esfuerzo/métodos , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/terapia , Adulto , Electrofisiología Cardíaca , Estudios de Cohortes , Electrocardiografía/métodos , Diseño de Equipo , Seguridad de Equipos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Prospectivos , Radiografía Torácica/métodos , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA