1.
Indian Pediatr ; 48(9): 689-96, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21169641

RESUMEN

OBJECTIVE: To compare phototherapy devices based on their physical and photo-biological characteristics viz spectral properties, maximum and mean irradiance, treatable percentage of body surface area, decay of irradiance over time and in vitro photoisomerisation of bilirubin. DESIGN: In vitro experimental study. SETTING: Ocular pharmacy laboratory at a tertiary care hospital. METHODLOGY: All the characteristics were measured at a fixed distance of 35 cm from one compact fluorescent lamp (CFL) and three light emitting diode (LED) phototherapy devices in a dark room with an irradiance of <0.1uW/cm2/nm. Estimation of products of in vitro photoisomerisation was done using liquid chromatography - tandem mass spectroscopy (LC-MS/MS). RESULTS: The emission spectral data were comparable between the phototherapy devices. The devices, however, differed in their maximum irradiance with the spot and indigenous LED units having the highest and lowest values, respectively (56.5 and 16.8uW/cm2/nm). The mean irradiance measured in 5x5cm grids falling within the silhouette of a term baby of the spot and improvised LED devices were low (26.8uW/cm2/nm and 11.5uW/cm2/nm, respectively) possibly due to unevenness in the irradiance of light falling within the silhouette. There was a significant difference in the amount of bilirubin left after exposure to light over a 2hour time period (% reduction of bilirubin) among the four devices (P=0.001); at 120 minutes after exposure, the amount of bilirubin left was lowest for the CFL (16%) and spot LED (17%) devices and highest for the indigenous LED unit (41%). CONCLUSIONS: The four phototherapy devices differed markedly in their physical and photobiological characteristics. Since the efficacy of a device is dependent not only on the maximum irradiance but also on the mean irradiance, rate of decay of irradiance, and treatable surface area of the foot print of light, each phototherapy device should have these parameters verified and confirmed before being launched for widespread use.


Asunto(s)
Hiperbilirrubinemia Neonatal/terapia , Fototerapia/instrumentación , Bilirrubina/metabolismo , Humanos , Hiperbilirrubinemia Neonatal/metabolismo , Recién Nacido , Fototerapia/normas , Reproducibilidad de los Resultados
2.
Indian Pediatr ; 47(2): 131-7, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19578227

RESUMEN

OBJECTIVE: To evaluate whether light-emitting diode (LED) phototherapy is as efficacious as compact fluorescent tube (CFT) phototherapy for the treatment of non-hemolytic jaundice in healthy term and late preterm neonates. STUDY DESIGN: Multi centre open label randomized controlled trial. SETTING: Four tertiary care neonatal units. SUBJECTS: Healthy term and late preterm neonates with non-hemolytic jaundice. INTERVENTION: Single-surface LED or CFT phototherapy. PRIMARY OUTCOME VARIABLE: Duration of phototherapy. RESULTS: A total of 272 neonates were randomized to receive LED (n=142) or CFT (n=130) phototherapy. The baseline demographic and biochemical variables were similar in the two groups. The median duration of phototherapy (IQR) in the two groups was comparable (26 (22-36) h vs. 25(22-36) h; P=0.44). At any time point, a similar proportion of neonates were under phototherapy in the two groups (log-rank test, P=0.38). The rate of fall of serum total bilirubin (STB) during phototherapy and the incidence of failure of phototherapy were also not different. An equal proportion of neonates had a rebound increase in STB needing restarting of phototherapy. Side effects were rare, comparable in the two groups and included hypothermia, hyperthermia, rash, skin darkening and dehydration. CONCLUSIONS: LED and CFT phototherapy units were equally efficacious in the management of non-hemolytic hyperbilirubinemia in healthy term and late preterm neonates.


Asunto(s)
Ictericia Neonatal/terapia , Fototerapia/instrumentación , Distribución de Chi-Cuadrado , Femenino , Humanos , Recién Nacido , Ictericia Neonatal/epidemiología , Estimación de Kaplan-Meier , Masculino , Fototerapia/métodos , Estadísticas no Paramétricas