Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
BMC Cardiovasc Disord ; 21(1): 319, 2021 06 30.
Artículo en Inglés | MEDLINE | ID: mdl-34193076

RESUMEN

BACKGROUND: Since the early descriptions of large series of accessory atrioventricular pathway ablations in adults and adolescents over 20 years ago, there have been limited published reports based on more recent experiences of large referral centers. We aimed to characterize accessory pathway distribution and features in a large community-based population that influence ablation outcomes using a tiered approach to ablation. METHODS: Retrospective analysis of 289 patients (age 14-81) who underwent accessory ablation from 2015-2019 was performed. Pathways were categorized into anteroseptal, left freewall, posteroseptal, and right freewall locations. We analyzed patient and pathway features to identify factors associated with prolonged procedure time parameters. RESULTS: Initial ablation success rate was 94.7% with long-term success rate of 93.4% and median follow-up of 931 days. Accessory pathways were in left freewall (61.6%), posteroseptal (24.6%), right freewall (9.6%), and anteroseptal (4.3%) locations. Procedure outcome was dependent on pathway location. Acute success was highest for left freewall pathways (97.1%) with lowest case times (144 ± 68 min) and fluoroscopy times (15 ± 19 min). Longest procedure time parameters were seen with anteroseptal, left anterolateral, epicardial-coronary sinus, and right anterolateral pathway ablations. CONCLUSIONS: In this community-based adult and adolescent population, majority of the accessory pathways are in the left freewall and posteroseptal region and tend to be more easily ablated. A tiered approach with initial use of standard ablation equipment before the deployment of more advance tools, such as irrigated tips and 3D mapping, is cost effective without sacrificing overall efficacy.


Asunto(s)
Fascículo Atrioventricular Accesorio/cirugía , Arritmias Cardíacas/cirugía , Ablación por Catéter/tendencias , Servicios de Salud Comunitaria/tendencias , Prestación Integrada de Atención de Salud/tendencias , Pautas de la Práctica en Medicina/tendencias , Irrigación Terapéutica/tendencias , Fascículo Atrioventricular Accesorio/diagnóstico , Fascículo Atrioventricular Accesorio/economía , Fascículo Atrioventricular Accesorio/fisiopatología , Potenciales de Acción , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/economía , Arritmias Cardíacas/fisiopatología , Ablación por Catéter/efectos adversos , Ablación por Catéter/economía , Toma de Decisiones Clínicas , Servicios de Salud Comunitaria/economía , Análisis Costo-Beneficio , Prestación Integrada de Atención de Salud/economía , Femenino , Costos de la Atención en Salud/tendencias , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Pautas de la Práctica en Medicina/economía , Estudios Retrospectivos , Irrigación Terapéutica/efectos adversos , Irrigación Terapéutica/economía , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
2.
Am J Cardiol ; 90(12): 1294-9, 2002 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-12480037

RESUMEN

This study was designed to assess the effects of tachycardia origin, the significance of atrial contribution, and the effects of left ventricular ejection fraction on hemodynamically tolerated ventricular tachycardia (VT) and supraventricular tachycardia (SVT). Forty-one subjects with inducible hemodynamically tolerated VT (n = 24) or SVT (n = 17) with mean ages of 60 +/- 13 and 40 +/- 16 years and mean ejection fractions of 32 +/- 15% and 59 +/- 5%, respectively, were studied. VT and SVT were induced by standard techniques, and femoral arterial blood pressure (BP) was recorded for 30 seconds. After tachycardia termination, with >/=3 minutes between conditions, ventricular overdrive pacing was performed from the right ventricular (RV) apex and then the RV outflow tract, followed by atrioventricular (AV) pacing at the tachycardia cycle length. Mean BP was measured every 5 seconds. Linear regression methods were used to model BP response for the 2 groups. There was a significant increase in BP over the 20-second interval after the induction of VT and SVT (0.55 +/- 0.21 and 1.0 +/- 0.20 mm Hg/s, respectively, p <0.05). In patients with hemodynamically tolerated VT, RV apex and RV outflow tract pacing at the tachycardia cycle length decreased BP by 6.7 +/- 2.0 (p <0.002) and 4.7 +/- 2.5 mm Hg (p = 0.06), respectively. AV pacing at the tachycardia cycle length did not improve BP compared with RV pacing alone. In patients with SVT, RV apex and RV outflow pacing at the tachycardia cycle length decreased BP by 5.6 +/- 2.9 (p = 0.05) and 4.1 +/- 2.7 mm Hg (p = 0.12), respectively. However, AV pacing at the tachycardia cycle length was associated with improved BP response over RV pacing alone. Increased age and lower ejection fraction adversely influenced BP response in the VT group and longer cycle length, and higher preinduction BP favorably influenced BP response in the SVT group. The determinants of BP response after tachycardia onset are complex and differ in patients with SVT and VT.


Asunto(s)
Presión Sanguínea/fisiología , Sistema de Conducción Cardíaco/fisiopatología , Taquicardia Supraventricular/fisiopatología , Taquicardia Ventricular/fisiopatología , Función Ventricular , Adulto , Factores de Edad , Determinación de la Presión Sanguínea/métodos , Estimulación Cardíaca Artificial/métodos , Técnicas Electrofisiológicas Cardíacas , Femenino , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Volumen Sistólico/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA