Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Matern Fetal Neonatal Med ; 33(1): 57-61, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29860925

RESUMEN

Background: The Bilicare™ is a new device that measures transcutaneous bilirubin (TcB) level at the ear pinna. There are only few studies which have evaluated its accuracy in clinical practice.Objective: This study aims to determine the accuracy of Bilicare™ as a predischarge screening tool in late preterm and term neonates and to define the optimal cutoff point for determining the need to measure total serum bilirubin (TSB).Methods: The 35 weeks' gestation or more and healthy neonates who underwent predischarge TSB measurement were enrolled. Bilicare™ TcB was measured within 30 minutes of blood sampling. Paired TcB and TSB data were analyzed.Results: We collected 214 paired samples. Mean age (SD) at TcB measurement was 57.17 (7.47) hours. Mean TSB (SD) was 9.79 (2.83) mg/dL. TcB showed a significant correlation with TSB (r = 0.84, r2 = 0.7). The mean difference (SD) between TcB and TSB was 0.7 (0.21) mg/dL (95%CI 0.49-0.91). TcB tended to overestimate TSB level at the TSB values of <12 mg/dL but underestimate at the higher TSB level. The accuracy of using TcB values to detect neonates who required phototherapy was 92.5%. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 78.3, 94.2, 62.1, and 97.3%, respectively. If TcB +3 mg/dL was applied as a cutoff point, the sensitivity, specificity, PPV, and NPV were 100, 53.9, 20.7, and 100%, respectively.Conclusions: Bilicare™ TcB and TSB measurements were well correlated. The TcB level +3 mg/dL could detect all neonates who had significant hyperbilirubinemia requiring phototherapy during their birth hospitalization.


Asunto(s)
Bilirrubina/sangre , Hiperbilirrubinemia Neonatal/diagnóstico , Tamizaje Neonatal/instrumentación , Alta del Paciente , Piel/diagnóstico por imagen , Bilirrubina/análisis , Estudios Transversales , Oído , Femenino , Edad Gestacional , Humanos , Hiperbilirrubinemia Neonatal/sangre , Recién Nacido , Enfermedades del Prematuro/sangre , Enfermedades del Prematuro/diagnóstico , Masculino , Tamizaje Neonatal/métodos , Tamizaje Neonatal/normas , Nacimiento Prematuro/sangre , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Piel/metabolismo , Nacimiento a Término/sangre , Factores de Tiempo
2.
J Matern Fetal Neonatal Med ; 33(10): 1688-1694, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-30235964

RESUMEN

Objectives: To develop an hour-specific transcutaneous bilirubin (TcB) nomogram for Thai neonates and to compare the ability of this nomogram with that of Bhutani's total serum bilirubin (TSB) nomogram for prediction of significant hyperbilirubinemia requiring phototherapy.Methods: Healthy Thai neonates, gestational age ≥35-week-gestation and birth weight ≥2000 grams were enrolled. Neonates who could not attend the postdischarge follow-up at our center were excluded. TcB measurements were routinely performed at 6 am and 6 pm using JM103 transcutaneous bilirubinometer until the neonates were discharged or received phototherapy. TcB levels were also measured at least once during 24-72 hours after discharge and thereafter depending on the pediatricians' decision. The nomogram was developed from the TcB data during age 12-144 hours of neonates who did not require phototherapy. The TcB values that obtained predischarge or before receiving phototherapy of all neonates were used to determine the predictive ability of this nomogram and Bhutani's TSB nomogram.Results: A total of 1071 neonates were included. Two hundred forty-one neonates (22.5%) required phototherapy. The nomogram was constructed using 4834 hour-specific TcB values. It provided a good prediction with the area under curve (AUC) of 0.89. The 75th percentile tract revealed sensitivity and negative predictive value (NPV) of 87.1 and 95.4% while that of the 40th percentile tract were 97.9 and 98.5% respectively. When Bhutani's nomogram was used, the AUC was 0.84. The sensitivity and NPV of the 75th percentile tract were 56.4 and 88.2%, and for the 40th percentile tract were 97.1 and 98.0% respectively.Conclusion: The newly developed TcB nomogram revealed slightly better predictive ability than Bhutani's TSB nomogram for term and late preterm Thai neonates who were the population with high prevalence of significant hyperbilirubinemia. The 40th percentile curve of both nomograms should be considered as an appropriate cut-off level for prediction.


Asunto(s)
Bilirrubina/análisis , Hiperbilirrubinemia Neonatal/diagnóstico , Tamizaje Neonatal/instrumentación , Nomogramas , Pueblo Asiatico , Femenino , Humanos , Hiperbilirrubinemia Neonatal/epidemiología , Recién Nacido , Masculino , Valor Predictivo de las Pruebas , Embarazo , Estudios Prospectivos , Tailandia/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA