Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Medicinas Tradicionales
Métodos Terapéuticos y Terapias MTCI
Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Extra Corpor Technol ; 55(2): 70-81, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37378439

RESUMEN

BACKGROUND: Blood loss is common during surgical procedures, especially in open cardiac surgery. Allogenic blood transfusion is associated with increased morbidity and mortality. Blood conservation programs in cardiac surgery recommend re-transfusion of shed blood directly or after processing, as this decreases transfusion rates of allogenic blood. But aspiration of blood from the wound area is often associated with increased hemolysis, due to flow induced forces, mainly through development of turbulence. METHODS: We evaluated magnetic resonance imaging (MRI) as a qualitative tool for detection of turbulence. MRI is sensitive to flow; this study uses velocity-compensated T1-weighted 3D MRI for turbulence detection in four geometrically different cardiotomy suction heads under comparable flow conditions (0-1250 mL/min). RESULTS: Our standard control suction head Model A showed pronounced signs of turbulence at all flow rates measured, while turbulence was only detectable in our modified Models 1-3 at higher flow rates (Models 1 and 3) or not at all (Model 2). CONCLUSIONS: The comparison of flow performance of surgical suction heads with different geometries via acceleration-sensitized 3D MRI revealed significant differences in turbulence development between our standard control Model A and the modified alternatives (Models 1-3). As flow conditions during measurement have been comparable, the specific geometry of the respective suction heads must have been the main factor responsible. The underlying mechanisms and causative factors can only be speculated about, but as other investigations have shown, hemolytic activity is positively associated with degree of turbulence. The turbulence data measured in this study correlate with data from other investigations about hemolysis induced by surgical suction heads. The experimental MRI technique used showed added value for further elucidating the underlying physical phenomena causing blood damage due to non-physiological flow.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Hemólisis , Humanos , Succión , Imagen por Resonancia Magnética , Transfusión de Sangre Autóloga/métodos
2.
Perfusion ; 34(1): 58-66, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30052109

RESUMEN

BACKGROUND: Re-transfusion of autologous blood is an important aspect of intraoperative blood management. Hemolysis and platelet dysfunction due to turbulence in the blood suction system strongly impede later usage of suction blood for re-transfusion. The aim of this study was to analyze the effects of a novel surgical-blood suction system with an automatic control setup for minimization of turbulence in the blood flow. METHODS: We compared the turbulence-controlled suction system (TCSS) with a conventional suction system and untreated control blood in vitro. Blood cell counts, hemolysis levels according to free hemoglobin (fHb) and platelet function were analyzed to determine the integrity of the suction blood. RESULTS: In the conventional suction system, we found a strong increase of the fHb levels. In contrast, erythrocyte integrity was almost completely preserved when using the TCSS. We obtained similar results regarding platelet function. The expression of platelet glycoproteins, such as GP IIb/IIIa and P-selectin, native or after stimulation with ADP, were markedly impaired by the conventional system, but not by the TCSS. In addition, platelet aggregometry revealed significant platelet dysfunction in conventional suction blood, but less aggregation impairments were present in blood samples from the TCSS. CONCLUSION: Our findings on an in vitro assessment show major improvements in red blood cell integrity and platelet function of suction blood when using the TCSS compared to a conventional suction system. These results reflect a significant benefit for autologous re-transfusion. We suggest testing the TCSS in surgery for clinical evaluation.


Asunto(s)
Pérdida de Sangre Quirúrgica/prevención & control , Plaquetas/patología , Transfusión de Sangre Autóloga , Hemólisis , Succión/instrumentación , Puente Cardiopulmonar , Hemoglobinas/análisis , Hemostasis , Humanos , Pruebas de Función Plaquetaria , Estudios Prospectivos , Procedimientos Quirúrgicos Vasculares
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA