RESUMEN
Acute phase proteins are useful inflammatory markers in horses. Haptoglobin (Hp) serum level is increased in horses undergoing different inflammatory processes, including arthritis. However, Hp concentration has not been assessed in inflammatory synovial fluid (SF). The aim of the present study was to investigate the Hp response in serum and SF in horses undergoing experimentally induced arthritis. For this purpose, serum and SF samples were collected from 12 animals before amphotericin B-induced arthritis was created (T0, healthy) and 15days after the lesion induction (T1, joint inflammation) and Hp was determined by single radial immunodiffusion. The Hp increase between T0 and T1 was significant in both serum and SF, and serum Hp concentration at T0 was significantly higher than in SF, but significant differences were not found at T1, indicating a higher Hp increase in SF. A significant positive correlation for Hp concentration between serum and SF samples was found. These results highlight the potential usefulness of Hp as inflammatory marker in horses, showing for the first time the increase of Hp in SF from joint inflammation in the horse.
Asunto(s)
Artritis/veterinaria , Haptoglobinas/metabolismo , Enfermedades de los Caballos/sangre , Enfermedades de los Caballos/metabolismo , Animales , Artritis/sangre , Artritis/metabolismo , Artritis Experimental/sangre , Artritis Experimental/metabolismo , Biomarcadores/sangre , Biomarcadores/metabolismo , Caballos , Mediadores de Inflamación/sangre , Mediadores de Inflamación/metabolismo , Masculino , Líquido Sinovial/metabolismo , Factores de TiempoRESUMEN
Llevamos a cabo un estudio en 35 pacientes en los cuales realizamos la operación de Putti-Platt para corrección de inestabilidad anterior del hombro. En estos pacientes se utilizó anestesia local intra y extraarticular con bupivacaína 0.2 por ciento en solución con epinefrina 1:500,000, aplicando dosis máximas de 40 mg. La operación de Putti-Platt se realizó a través de una vía de abordaje de tamaño no mayor de 4 cm. La tolerancia a las intervenciones fue excelente en todos los casos requiriéndose dosis mínimas de fentanyl/diacepam para proporcionar al paciente una sedación mínima y un confort adecuados. La analgesia postoperatoria también fue excelente, en algunos pacientes hasta por 16 horas. No existieron complicaciones atribuibles al método anestésico ni a la técnica quirúrgica. La rehabilitación fue más temprana y el tiempo de hospitalización disminuyó ya que el paciente puede ser manejado incluso como ambulatorio