Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Cardiovasc Electrophysiol ; 31(6): 1436-1447, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32227530

RESUMEN

INTRODUCTION: Accurate identification of slow conducting regions in patients with scar-related atrial tachycardia (AT) is difficult using conventional electrogram annotation for cardiac electroanatomic mapping (EAM). Estimating delays between neighboring mapping sites is a potential option for activation map computation. We describe our initial experience with CARTO 3 Coherent Mapping (Biosense Webster Inc,) in the ablation of complex ATs. METHODS: Twenty patients (58 ± 10 y/o, 15 males) with complex ATs were included. We created three-dimensional EAMs using CARTO 3 system with CONFIDENSE and a high-resolution mapping catheter (Biosense Webster Inc). Local activation time and coherent maps were used to aid in the identification of conduction isthmus (CI) and focal origin sites. System-defined slow or nonconducting zones and CI, defined by concealed entrainment (postpacing interval < 20 ms), CV < 0.3 m/s and local fractionated electrograms were evaluated. RESULTS: Twenty-six complex ATs were mapped (mean: 1.3 ± 0.7 maps/pt; 4 focal, 22 isthmus-dependent). Coherent mapping was better in identifying CI/breakout sites where ablation terminated the tachycardia (96.2% vs 69.2%; P = .010) and identified significantly more CI (mean/chamber 2.0 ± 1.1 vs 1.0 ± 0.7; P < .001) with narrower width (19.8 ± 10.5 vs 43.0 ± 23.9 mm; P < .001) than conventional mapping. Ablation at origin and CI sites was successful in 25 (96.2%) with long-term recurrence in 25%. CONCLUSIONS: Coherent mapping with conduction velocity vectors derived from adjacent mapping sites significantly improved the identification of CI sites in scar-related ATs with isthmus-dependent re-entry better than conventional mapping. It may be used in conjunction with conventional mapping strategies to facilitate recognition of slow conduction areas and critical sites that are important targets of ablation.


Asunto(s)
Potenciales de Acción , Cicatriz/complicaciones , Técnicas Electrofisiológicas Cardíacas , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca , Taquicardia Supraventricular/diagnóstico , Anciano , Algoritmos , Ablación por Catéter , Cicatriz/diagnóstico , Femenino , Sistema de Conducción Cardíaco/cirugía , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Proyectos Piloto , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Procesamiento de Señales Asistido por Computador , Taquicardia Supraventricular/etiología , Taquicardia Supraventricular/fisiopatología , Taquicardia Supraventricular/cirugía , Factores de Tiempo , Resultado del Tratamiento
2.
J Cardiovasc Electrophysiol ; 30(6): 952-963, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30983063

RESUMEN

INTRODUCTION: Phase singularity (PS) mapping provides additional insight into the AF mechanism and is accurate in identifying rotors. The study aimed to evaluate the feasibility of PS mapping in identifying AF rotors using data obtained from an automatic ultra-rapid high-resolution mapping system with a high-density mini-basket catheter. METHODS: Twenty-three pigs underwent rapid right atrial (RA) pacing (RAP 480 bpm) for 5 weeks before the experiment. During AF, RA endocardial automatic continuous mappings with a mini-basket catheter were generated using an automatic ultra-rapid mapping system. Both fractionation mapping and waveform similarity measurements using a PS mapping algorithm were applied on the same recording signals to localize substrates maintaining AF. RESULTS: Seventeen (74%) pigs developed sustained AF after RAP. Three were excluded because of periprocedural ventricular arrhythmia and corrupted digital data. RA fractionation maps were acquired with 6.17 ± 4.29 minutes mean acquisition time, 13768 ± 12698 acquisition points mapped during AF from 581 ± 387 beats. Fractionation mapping identified extensively distributed (66.7%) RA complex fractionated atrial electrogram (CFAE), whereas the nonlinear analysis identified high similarity index (SI > 0.7) parts in limited areas (23.7%). There was an average of 1.67 ± 0.87 SI sites with 0.43 ± 0.76 rotor/focal source/chamber. AF termination occurred in 11/16 (68.75%) AF events in 14 pigs during ablation targeting max CFAE. There was a higher incidence of rotor/focal source at AF termination sites compared with non-AF termination sites (54.5% vs 0%, P = 0.011). CONCLUSIONS: The data obtained from ultra-rapid high-density automatic mapping is feasible and effective in identifying AF rotors/focal sources using PS technique, and those critical substrates were closely related to AF procedural termination.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial/diagnóstico , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca , Algoritmos , Animales , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Catéteres Cardíacos , Ablación por Catéter , Modelos Animales de Enfermedad , Técnicas Electrofisiológicas Cardíacas/instrumentación , Estudios de Factibilidad , Sistema de Conducción Cardíaco/cirugía , Valor Predictivo de las Pruebas , Procesamiento de Señales Asistido por Computador , Sus scrofa , Factores de Tiempo
3.
Pacing Clin Electrophysiol ; 42(2): 216-223, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30536679

RESUMEN

INTRODUCTION: Adjunctive driver-guided ablation in addition to pulmonary vein isolation has been proposed as a strategy to improve procedural success and outcomes for various populations with atrial fibrillation (AF). First, this study aimed to evaluate the different mapping techniques for driver/rotor identification and second to evaluate the benefits of driver/rotor-guided ablation in patients with paroxysmal and persistent AF (PerAF). METHODS: We searched the electronic database in PubMed using the keywords "atrial fibrillation," "rotor," "rotational driver," "atrial fibrillation source," and "drivers" for both randomized controlled trials and observational controlled trials. Clinical studies reporting efficacy or safety outcomes of driver-guided ablation for paroxysmal AF or (PerAF) were identified. We performed subgroup analyses comparing different driver mapping methods in patients with PerAF. The odds ratios (ORs) with random effects were analyzed. RESULTS: Out of 175 published articles, seven met the inclusion criteria, of which two were randomized controlled trials, one was quasiexperimental study, and four observational studies (three case-controlled studies and one cross-sectional study). Overall, adjunctive driver-guided ablation was associated with higher rates of acute AF termination (OR: 4.62, 95% confidence interval [CI]: 2.12-10.08; P < 0.001), lower recurrence of any atrial arrhythmia (OR: 0.44, 95% CI: 0.30-0.065; P < 0.001), and comparable complication incidence. CONCLUSIONS: Adjunctive driver-guided catheter ablation suggested an increased freedom from AF/AT relative to conventional strategies, irrespective of the mapping techniques. Furthermore, phase mapping appears to be superior to electrogram-based driver mapping in PerAF ablation.


Asunto(s)
Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Humanos , Estudios Observacionales como Asunto , Ensayos Clínicos Controlados Aleatorios como Asunto
4.
Int J Cardiol ; 272: 90-96, 2018 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-30173923

RESUMEN

BACKGROUND: Intracardiac electrogram recording is influenced by the electrode size and inter-electrode spacing. Smaller electrodes with a closer inter-electrode spacing may improve the mapping resolution and outcome. METHODS: Substrate mapping of the left atrium and residual pulmonary vein (PV) potentials during sinus rhythm was sequentially performed using a 3.5-mm electrode tip catheter and a 1-mm electrode multielectrode catheter in 33 patients (Group 1) that underwent repeat atrial fibrillation (AF) procedures. PV gap identification and electrophysiological characteristics were compared. Arrhythmia freedom was compared with a propensity matched (1:2) control group (66 patients, Group 2) undergoing repeat AF procedures guided by wide inter-electrode spacing catheter. RESULTS: In the Group 1 patients, the total area of residual PV potentials measured using the 1-mm catheter was larger than that measured by the 3.5-mm catheter. Overall 1.97 ±â€¯0.59 (1-3) and 1.49 ±â€¯0.62 (1-3) PVs were identified by the 1-mm electrode and 3.5 mm catheters, respectively (P = 0.02). The gaps not identified by the 3.5 mm catheter had a smaller width and lower voltage. Radiofrequency catheter ablation in the areas with residual PV potentials identified by the 1-mm catheter resulted in complete electrical isolation of the PVs. Arrhythmia freedom at one year of follow-up was achieved in 26 of 33 (78.8%) patients in Group 1, which was significantly higher than the matched control group (33/66 [50%], P < 0.05). CONCLUSION: In the patients with a previous PV isolation, mapping with small, closely spaced electrodes can increase the detection rate of residual PV potentials and improve the outcome.


Asunto(s)
Ablación por Catéter/instrumentación , Electrocardiografía/instrumentación , Técnicas Electrofisiológicas Cardíacas/instrumentación , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Angiografía por Tomografía Computarizada/instrumentación , Angiografía por Tomografía Computarizada/métodos , Electrocardiografía/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Femenino , Humanos , Masculino , Microelectrodos , Persona de Mediana Edad , Estudios Prospectivos
5.
J Cardiovasc Electrophysiol ; 29(2): 298-307, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29071756

RESUMEN

BACKGROUND: Septal ventricular outflow tract ventricular arrhythmias (OT-VAs) are defined as septal origin VAs from the right ventricular or left ventricular OT. Patients with septal OT-VAs may require a sequential bilateral OT ablation. This study aimed to evaluate the electrophysiological characteristics and ablation outcome in patients with septal OT-VAs. METHODS: We retrospectively analyzed the electrocardiography and electrophysiological parameters in 96 patients (mean age 49 ± 15 years, 49 male) undergoing bilateral activation mapping before catheter ablation of idiopathic septal OT-VAs. The patients were categorized into three groups based on the successful ablation sites, including the right ventricular outflow tract (RVOT), RVOT/left ventricular outflow tract (LVOT), and LVOT. RESULTS: Mapping in the three groups demonstrated a gradually decreasing and increasing trend in the earliest activation time obtained from the RVOT and LVOT, respectively. The absolute earliest activation time discrepancy (AEAD) of ≤18 milliseconds could predict the requirement for a sequential bilateral ablation with a sensitivity and specificity of 100.0% and 93.7%, respectively. The small AEAD (≤21 milliseconds) was associated with a higher recurrence rate in patients receiving a successful unilateral ablation, while patients with a longer distance between the bilateral OT earliest activation sites (DEA > 26 mm) increased future recurrences after an initially successful sequential bilateral ablation. CONCLUSIONS: The application of bilateral OT-VA activation mapping and the measurement of the AEAD and DEA provided not only pivotal information for the ablation strategy, but also prognostic implications for recurrences in patients with septal OT-VAs.


Asunto(s)
Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas , Taquicardia Ventricular/cirugía , Tabique Interventricular/cirugía , Potenciales de Acción , Adulto , Anciano , Ablación por Catéter/efectos adversos , Electrocardiografía , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda , Función Ventricular Derecha , Tabique Interventricular/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA