Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Thorac Dis ; 15(12): 6889-6897, 2023 Dec 30.
Artículo en Inglés | MEDLINE | ID: mdl-38249895

RESUMEN

Background: The detection of pulmonary nodules significantly impacts the lives and mental health of patients. Although the 2020 National Comprehensive Cancer Network (NCCN) guidelines recommend scheduled surveillance for nodules ≤8 mm, patients often opt to have their nodules surgically removed. Methods: A cross-sectional questionnaire was administered to patients with small pulmonary nodules who presented to a local grade 3 hospital with small pulmonary nodules and decided to receive surgery versus prescribed monitoring. The questionnaire included four aspects: (I) patient characteristics; (II) nodule-specific knowledge; (III) doctor-patient communication; and (IV) nodular-specific distress. Nodular-specific distress was measured by the Impact of Event Scale-Revised (IES-R). Results: A total of 234 (69%) patients responded to the survey and were included in the final analysis. Poor performance in activities of daily living (ADLs), the presence of solid nodules, multifocal disease, and a family history of lung cancer were significantly associated with reported anxiety. Most notably, facilitating patient choice for surgery was the computed tomography (CT) scan results, with reference to lung nodule size and number of nodules, where concerns related to lung nodule, cancer risk, and fear of surgery or death had a significant psychological impact on patients. Conclusions: In this cohort of patients who elected to have their small pulmonary nodules surgically removed, we identified key factors underlying their anxiety toward guideline recommended surveillance. Our findings will be useful for clinicians when discussing treatment options with their patients.

2.
Prep Biochem Biotechnol ; 47(9): 881-888, 2017 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-28708469

RESUMEN

In this study, an efficient ultrasound-assisted aqueous two-phase extraction method was used for the extraction of anthocyanins from Lycium ruthenicum Murr. An ethanol/ammonium sulfate system was chosen for the aqueous two-phase system due to its fine partitioning and recycling behaviors. Single-factor experiments were conducted to determine the optimized composition of the system, and the response surface methodology was used for the further optimization of the ultrasound-assisted aqueous two-phase extraction. The optimal conditions were as follows: a salt concentration of 20%, an ethanol concentration of 25%, an extraction time of 33.7 min, an extraction temperature of 25°C, a liquid/solid ratio of 50:1 w/w, pH value of 3.98, and an ultrasound power of 600 W. Under the above conditions, the yields of anthocyanins reached 4.71 mg/g dry sample. For the further purification, D-101 resin was used, and the purity of anthocyanins reached 25.3%. In conclusion, ultrasound-assisted aqueous two-phase extraction was an efficient, ecofriendly, and economical method, and it may be a promising technique for extracting bioactive components from plants.


Asunto(s)
Antocianinas/aislamiento & purificación , Fraccionamiento Químico/métodos , Lycium/química , Extractos Vegetales/química , Sonicación/métodos , Sulfato de Amonio/química , Etanol/química , Transición de Fase
3.
Med Devices (Auckl) ; 6: 203-9, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24348077

RESUMEN

Devices which can obtain comparable bilaterally symmetrical acupoints (BSA) multifrequency impedances (MFI) are often needed in the detection of the energy balance states of acupoints in traditional Chinese medicine. To satisfy these needs, a two-channel impedance measurement system has been introduced which is capable of accurately and simultaneously measuring BSA MFI. The system includes a set of five electrodes, two of which are injected with exciting current signal to synchronously and equally excite BSA; the other three electrodes are used as sensors to simultaneously sense the response signal from both sides. The system also includes a PC-based time-domain signal testing platform with arbitrary current waveform generation and three channels (one exciting current and two response voltages) simultaneously sampling, and a set of MFI simultaneously unbiased computing algorithms based on special odd multisine current signal input. Preliminary validating experiments suggest that the system allows accurate and synchronous measurement of BSA MFI at least in the frequency range of 10 Hz to 60 kHz, and the obtained BSA MFI are well comparable.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA