Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Lab Med ; 51(1): 50-55, 2020 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-31150549

RESUMEN

OBJECTIVE: To evaluate how clinical practice was affected by the change in direct antiglobulin testing (DAT) methodologies and subsequent stronger reported DAT results at our large academic medical center. METHOD: We retrospectively reviewed DAT results of umbilical cord blood from infants with blood type A or B born to mothers with antibody-negative type O blood, based on records kept at the University of Alabama at Birmingham (UAB) Hospital, a 1400-bed academic medical center. RESULTS: We randomly chose 50 neonates with positive DAT results who had been tested using the tube method and 50 whose testing had used the gel method. Although 86% of results with the tube method were positive microscopically, 52% and 40% of the DAT results with the gel method were 1+ and 2+ positive, respectively. Further, we observed an increase in the number of neonates treated with phototherapy who had been tested using the gel method. CONCLUSION: We report that DATs performed using the gel method had increased DAT strength compared with tube testing, which led to increased use of phototherapy by our clinical colleagues.


Asunto(s)
Prueba de Coombs/normas , Hiperbilirrubinemia/sangre , Fototerapia/estadística & datos numéricos , Sistema del Grupo Sanguíneo ABO/inmunología , Centros Médicos Académicos/estadística & datos numéricos , Automatización de Laboratorios/métodos , Automatización de Laboratorios/normas , Prueba de Coombs/métodos , Femenino , Humanos , Hiperbilirrubinemia/diagnóstico , Hiperbilirrubinemia/terapia , Recién Nacido , Masculino , Distribución Aleatoria
2.
J Clin Apher ; 34(4): 490-494, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30673128

RESUMEN

PURPOSE: During a national shortage of calcium gluconate, we switched to calcium chloride for routine supplementation for peripheral blood stem cell (PBSC) collections. Subsequently, we analyzed the postprocedure ionized calcium level, as we aimed for an equivalent result compared to before the shortage. METHODS: Pharmacy representatives helped us to find an "equivalent" substitute for calcium gluconate at 46.5 mEq in 500 mL normal saline, infused at 100 mL/hour. After instituting a presumably comparable protocol using calcium chloride (40.8 mEq in 250 mL normal saline at a rate of 100 mL/hour), we reviewed ionized calcium results post-PBSC procedures to compare with those obtained with calcium gluconate. Having noticed a difference in the mean values, we adjusted the rate of calcium chloride to reach our desired outcome. RESULTS: Twenty-seven procedures were analyzed on 15 unique patients. We used the Spectra OPTIA with a whole blood: anticoagulant ratio of 13:1. Ionized calcium levels post-PBSC collection with the first calcium chloride protocol were significantly higher (P = 0.003) in nine patients treated. Subsequently, we decreased the calcium chloride infusion rate to 75 mL/hour and achieved similar mean levels to calcium gluconate (P = 0.382). CONCLUSION: Changes in replacement fluids for apheresis procedures can be complex, particularly when dealing with electrolytes that could be clinically significant at critically high or low levels. Once we recognized the need to take into account the amount of elemental calcium infused, we achieved the desired postprocedure ionized calcium results. This study can serve as a lesson for future shortages of infusions used during apheresis procedures.


Asunto(s)
Gluconato de Calcio/provisión & distribución , Calcio/administración & dosificación , Citaféresis/métodos , Calcio/farmacocinética , Cloruro de Calcio/administración & dosificación , Humanos , Células Madre de Sangre Periférica/citología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA