Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Orthop Res ; 37(7): 1489-1497, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30644138

RESUMEN

Particle-induced implant loosening is a major challenge to long-term survival of joint prostheses. Administration of intermittent parathyroid hormone (PTH) has shown potential in the treatment of cases of early-stage periprosthetic osteolysis, while sequential administration of intermittent PTH (iPTH) and bisphosphonates (Bps) has achieved significant effects on treatment of postmenopausal osteoporosis. The objective of this study was to determine whether sequential treatment could preserve bone mass and implant fixation during a pathological course of peri-implant osteolysis in a rat model. Ninety male Sprague Dawley rats were randomly divided into nine groups, four of which were used for confirmation of establishment of the peri-implant osteolysis model at two time points, while the other five were used to determine the efficiency of the sequential treatment on peri-implant osteolysis. Implant fixation and peri-implant bone mass were evaluated using biomechanical testing, micro-CT analysis, and histology at 6 and 12 weeks postoperative. The biomechanical test demonstrated that the maximum loading force during a push-out test was significantly elevated in the sequential treatment group compared to the osteolysis group and iPTH withdrawal group at 12 weeks. Peri-implant bone morphology also indicated a robust increase in bone volume in the sequential treatment group. Sequential administration of iPTH and Bps was effective in preventing experimental peri-implant osteolysis, resulting in improved implant fixation and increased peri-implant bone volume. Clinical significance: The innovative application of sequential treatment in peri-implant osteolysis could be used clinically to improve the prognosis of patients with early-stage periprosthetic osteolysis. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:1489-1497, 2019.


Asunto(s)
Conservadores de la Densidad Ósea/administración & dosificación , Osteólisis/tratamiento farmacológico , Hormona Paratiroidea/administración & dosificación , Falla de Prótesis/efectos de los fármacos , Ácido Zoledrónico/administración & dosificación , Animales , Huesos/diagnóstico por imagen , Huesos/patología , Evaluación Preclínica de Medicamentos , Masculino , Osteólisis/diagnóstico por imagen , Osteólisis/etiología , Osteólisis/patología , Distribución Aleatoria , Ratas Sprague-Dawley , Microtomografía por Rayos X
2.
Environ Sci Pollut Res Int ; 24(11): 10570-10583, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28283969

RESUMEN

The secondary effluent from biological treatment process in chemical industrial plant often contains refractory organic matter, which deserves to be further treated in order to meet the increasingly stringent environmental regulations. In this study, the key role of biogenic manganese oxides (BioMnOx) in enhanced removal of highly recalcitrant 1,2,4-triazole from bio-treated chemical industrial wastewater was investigated. BioMnOx production by acclimated manganese-oxidizing bacterium (MOB) consortium was confirmed through scanning electronic microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and X-ray diffraction (XRD) analysis. Pseudomonas and Bacillus were found to be the most predominant species in acclimated MOB consortium. Mn2+ could be oxidized optimally at neutral pH and initial Mn2+ concentration below 33 mg L-1. However, 1,2,4-triazole removal by BioMnOx produced occurred optimally at slightly acidic pH. High dosage of both Mn2+ and 1,2,4-triazole resulted in decreased 1,2,4-triazole removal. In a biological aerated filter (BAF) coupled with manganese oxidation, 1,2,4-triazole and total organic carbon removal could be significantly enhanced compared to the control system without the participation of manganese oxidation, confirming the key role of BioMnOx in the removal of highly recalcitrant 1,2,4-triazole. This study demonstrated that the biosystem coupled with manganese oxidation had a potential for the removal of various recalcitrant contaminants from bio-treated chemical industrial wastewater.


Asunto(s)
Compuestos de Manganeso/química , Triazoles/química , Aguas Residuales , Manganeso/química , Oxidación-Reducción , Óxidos/química
3.
Chin Med J (Engl) ; 125(2): 244-8, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22340553

RESUMEN

BACKGROUND: Ceramic bearing surfaces have been introduced to prevent osteolysis after total hip arthroplasty (THA), but little is known about the difference in clinical and radiological results between pure alumina and sandwich alumina bearings. The purpose of this study was to analyze the results obtained with third-generation alumina-on-alumina THA with two different designs both in liner and femoral stem fixation after a minimum follow-up of 4.2 years. METHODS: The results of 195 primary alumina-on-alumina THAs in 167 patients were evaluated. The procedures were performed between January 1998 and October 2006. Three patients died and 11 patients were lost to follow-up, leaving a total of 153 patients (181 hips) available for study. In the 88 group A patients, 107 hips were implanted using pure alumina bearings with cementless femoral stems. These patients were followed for (6.84 ± 1.49) years. In the 65 group B patients, 74 hips were implanted using sandwich alumina ceramic bearings with cemented femoral stems. These patients had a follow-up period of (7.73 ± 1.60) years. Patients in both groups were evaluated clinically and radiographically. RESULTS: One ceramic liner fracture occurred in group A and five took place in group B (P < 0.05), four of them revised for liner fracture. In each group, one acetabular shell migration happened without liner breakage and two hips developed deep infections, and all these six hips received revisions. Nine femoral components loosened in group B, with seven undergoing revisions. Kaplan-Meier survivorship at 5 years for revision of any component for any reason in group A was 96.26% compared to 90.54% in group B (P < 0.05). Better function was determined in group A (average Harris hip scores: 92.13 ± 2.85) than in group B (average Harris hip scores: 86.03 ± 4.21) and the difference was significant (P < 0.05). Squeaking was not recorded in either group. CONCLUSIONS: The sandwich design of the acetabular bearings can not reduce the migration rate in ceramic bearings but increase the liner fracture rate compared to pure ceramic liners. The high loosening rate in fluted and taped designed cemented stems with sandwich liners warrant caution to their use.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Adulto , Anciano , Anciano de 80 o más Años , Óxido de Aluminio , Cerámica , Femenino , Prótesis de Cadera , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Resultado del Tratamiento
4.
Zhonghua Yi Xue Za Zhi ; 91(47): 3316-9, 2011 Dec 20.
Artículo en Chino | MEDLINE | ID: mdl-22333195

RESUMEN

OBJECTIVE: To explore the intermediate outcomes of third-generation alumina-on-alumina total hip arthroplasty (THA). METHODS: A consecutive series of 165 primary alumina-on-alumina total hip arthroplasties were performed in 135 patients. Three patients died and 13 patients lost follow-up so that a total of 119 patients (146 hips) were available for study. The mean patient age was 53.4 ± 11.0 years old (range: 26 - 79). Hydroxyapatite. (HA)-coated press-fit acetabular cups were used in all cases. At femoral side, 123 cases were implanted with HA-coated uncemented stems and 23 cases implanted with high polished double taped cemented stems. All patients were evaluated clinically and radiographically after a minimal follow-up duration of 60 months. RESULTS: The preoperative mean Harris hip score of 49.6 ± 7.9 points improved to 91.7 ± 3.0 points at the last follow-up (P < 0.05). The 5-year survival for any reason lead to revision was 96.6%. Five hips were under revision, 1 for acetabular shell loosening and migration, 1 for Vancouver B2 periprosthetic fracture, 1 for fracture of pure alumina liner and 2 for infections. All other prostheses demonstrated no radiographic evidence of loosening. No periprosthetic osteolysis was found. There were 2 cases of dislocations and 2 patients presented postoperatively with "squeaking-like" hips. CONCLUSION: The clinical and radiographic outcomes after primary THA with third-generation ceramic-on-ceramic bearing surfaces are favorable after a minimal follow-up duration of 5 years. The modified alumina-on-alumina bearing implants offer a better option for younger and active patients.


Asunto(s)
Óxido de Aluminio , Artroplastia de Reemplazo de Cadera/instrumentación , Cerámica , Prótesis de Cadera , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA