Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Heart Rhythm ; 18(12): 2148-2157, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34438043

RESUMEN

BACKGROUND: Ventricular arrhythmias (VAs) ablated successfully at the right-left subvalvular interleaflet triangle (R-L ILT) between right and left coronary cusps have not been fully characterized. OBJECTIVE: The purpose of this study was to investigate the electrophysiological characteristics of these VAs and their relationships with the left ventricular (LV) summit. METHODS: Twenty-eight VAs ablated successfully at the R-L ILT were studied. RESULTS: Ninety-six percent of VAs had an early precordial electrocardiographic transition. R-wave amplitude in lead V1 was relatively high (RS morphology, R-wave amplitude 0.35 ± 0.09 mV; R/S ratio 0.35 ± 0.27), whereas the morphology of lead I was R-shaped in 71% and M-shaped in 50% of VAs. Earliest potential was recorded at the R-L ILT in 13 of 28 patients and the left pulmonary sinus cusp (LC) in 6 of 28 patients. Mapping the summit communicating vein (summit-CV) failed because of anatomic or instrumental limitations in these 19 patients. In the other 9 patients, earliest potential was successfully recorded at the summit-CV, while perfect pacemapping was achieved. Poor pace mapping was achieved at the R-L ILT or LC in most patients (27/28). Target site was located at the top of the R-L ILT in all cases. A presystolic potential was present at the target site in 18 of 28 patients. A U-curve via the retrograde method was conventionally used to reach the top of the R-L ILT. CONCLUSION: VAs ablated successfully at the R-L ILT have unique electrophysiological characteristics, and R-L ILT may be an endocardial anatomic ablation target for VAs originating from the base of the LV summit.


Asunto(s)
Mapeo del Potencial de Superficie Corporal/métodos , Ablación por Catéter , Sistema de Conducción Cardíaco , Taquicardia Ventricular , Adulto , Electrofisiología Cardíaca , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Electrocardiografía/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Femenino , Sistema de Conducción Cardíaco/patología , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Masculino , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/terapia , Resultado del Tratamiento
2.
BMJ Open ; 11(8): e045302, 2021 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-34341035

RESUMEN

INTRODUCTION: Recent studies have shown that the His-Purkinje system pacing (HPSP) can achieve electrocardiomechanical synchronisation, and thus improve cardiac function. For patients with pacing-induced cardiomyopathy (PICM) who should be treated with pacemaker upgrade, the HPSP is a viable alternative to cardiac resynchronisation therapy (CRT). However, no randomised controlled trial has been performed to evaluate the efficacy and safety of HPSP in patients with PICM. The present study compared the efficacy and safety of HPSP with that of traditional CRT in the treatment of patients with PICM. METHODS AND ANALYSIS: This study is a single-centre, randomised controlled non-inferiority trial. This trial was carried out at the cardiac centre of Beijing Anzhen Hospital. A total of 46 patients with PICM who needed pacemaker upgrade treatment between January 2022 and December 2023 will be enrolled in this study. Patients will be randomised into an investigational group (HPSP) and a control group (CRT) at a 1:1 ratio. The primary outcome is the duration of QRS complex (QRS width), and the secondary outcomes are NT-proBNP (N terminal pro B type natriuretic peptide), C reactive protein, the number of antibiotics used, left ventricular ejection fraction, end systolic volume, end diastolic volume, the hospitalisation duration, the incidence of postoperative infection, pacemaker parameters (threshold, sensing and impedance), the 6-minute walking test, and quality of life (36-Item Short Form Survey scale), all-cause mortality, cardiovascular death, heart failure-related rehospitalisation rate, other rehospitalisation rates, major complication rates and procedure costs. ETHICS AND DISSEMINATION: This study has been approved by the Beijing Anzhen Hospital Medical Ethics Committee (No. 2020043X). TRIAL REGISTRATION NUMBER: Chinese Clinical Trial Registry (ChiCTR2000034265).


Asunto(s)
Terapia de Resincronización Cardíaca , Cardiomiopatías , Insuficiencia Cardíaca , Cardiomiopatías/terapia , Insuficiencia Cardíaca/terapia , Humanos , Calidad de Vida , Ensayos Clínicos Controlados Aleatorios como Asunto , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
3.
Biomater Sci ; 9(14): 4843-4853, 2021 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-33998610

RESUMEN

Iridium(iii) complexes are potent candidates for photodynamic therapy (PDT), but some key drawbacks still hamper clinical translation, such as poor operability in the phototherapeutic window, high dark toxicity, and low reactive oxygen species (ROS) production efficiency. In this work, a near-infrared phosphorescent Ir(iii) complex conjugated to a xanthene dye, NIR-Ir-XE, is reported with highly favourable properties for mitochondria-targeted imaging and cancer phototherapy. The generation of the triplet excited state of a xanthene moiety endows the NIR-Ir-XE to form singlet oxygen (1O2) for use as a photodynamic therapy agent after irradiation with visible light. Compared with the xanthene-free Ir(iii) counterpart (NIR-Ir-bpy), the xanthene-modified cyclometalated Ir(iii) photosensitizer NIR-Ir-XE exhibits higher 1O2 generation efficiency, negligible dark toxicity and a better therapeutic effect. Importantly, a clear correlation between cell death and intracellular generation of 1O2 derived from NIR-Ir-XE after light irradiation was demonstrated. The corresponding in vivo photo-antitumor performance was further demonstrated to be effective in tumor-bearing mice. The observed properties of NIR-Ir-XE qualify it as a promising PDT agent.


Asunto(s)
Iridio , Fotoquimioterapia , Animales , Ratones , Mitocondrias , Fármacos Fotosensibilizantes , Xantenos
4.
Pacing Clin Electrophysiol ; 44(10): 1691-1700, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33734464

RESUMEN

BACKGROUND: Left atrial posterior wall isolation (PWI) is commonly used with persistent atrial fibrillation (AF) ablation. However, potentials are often still recorded in the posterior wall after pulmonary vein isolation (PVI), roof linear ablation, and bottom linear ablation in clinical practice. We aimed to explore the methodological approach and electrophysiological characteristics of PWI. METHODS: A total of 36 patients who attended our center with long-standing persistent AF were retrospectively analyzed. After routine PVI and roof and bottom linear ablation, complete PWI was confirmed in sinus rhythm by voltage mapping and high-output pacing. Otherwise, activation mapping and voltage mapping were used to guide ablation on the line or inside the posterior wall until bidirectional block was achieved. RESULTS: The first-pass success rate of PWI was 39%. In the remaining 61% of patients with posterior wall electrograms, activation mapping in sinus rhythm showed that the earliest activation point was not on the ablation line but in a relatively dispersed focal area, possibly related to epicardial muscular sleeve insertion. Voltage mapping revealed a focal high-voltage area in the posterior wall matching the relatively dispersed earliest activation site, in which an average of five points of ablation achieved complete PWI without serious esophageal injury. The middle zone contained 80% of the additional posterior wall ablation points. CONCLUSIONS: PWI was performed safely and effectively with an average of five additional ablation points in the posterior wall in 61% of patients under the guidance of voltage mapping.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Fibrilación Atrial/fisiopatología , Técnicas Electrofisiológicas Cardíacas , Femenino , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/cirugía , Estudios Retrospectivos
5.
Heart Fail Rev ; 26(3): 735-745, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33098491

RESUMEN

Cardiac resynchronization therapy (CRT) based on biventricular pacing (BVP) is an invaluable intervention currently used in heart failure (HF) patients. The therapy involves electromechanical dyssynchrony, which can not only improve heart function and quality of life but also reduce hospitalization and mortality rates. However, approximately 30% to 40% of patients remain unresponsive to conventional BVP in clinical practice. In the recent years, extensive research has been employed to find a more physiological approach to cardiac resynchronization. The His-Purkinje system pacing (HPSP) including His bundle pacing (HBP) and left bundle branch area pacing (LBBaP) may potentially be the future of CRT. These technologies present various advantages including offering an almost real physiological pacing, less complicated procedures, and economic feasibility. Additionally, other methods, such as isolated left-ventricular pacing and multipoint pacing, may in the future be important but non-mainstream alternatives to CRT because currently, there is no strong evidence to support their effectiveness. This article reviews the current situation and latest progress in CRT, explores the existing technology, and highlights future prospects in the development of CRT.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Electrocardiografía , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos , Humanos , Calidad de Vida , Resultado del Tratamiento , Función Ventricular Izquierda
6.
Clin Cardiol ; 43(9): 1009-1016, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32506504

RESUMEN

BACKGROUND: Right atrial electroanatomical mapping may be combined with SoundStar 3D diagnostic ultrasound catheter (EAM-ICE) as a zero-fluoroscopy procedure for radiofrequency catheter ablation (RFCA). We aimed to evaluate the efficiency and safety of zero-fluoroscopy transseptal puncture guided by EAM-ICE and fluoroscopy combined with intracardiac echocardiography (F-ICE) in patients with paroxysmal atrial fibrillation (PAF). HYPOTHESIS: Zero-fluoroscopy transseptal puncture is an effective and safe procedure. METHODS: This study had a prospective design. A total of 57 patients with PAF were enrolled and assigned to two groups. Twenty-seven patients were enrolled in the EAM-ICE group, and 30 patients were enrolled in the F-ICE group. RESULTS: There were no statistically significant differences in baseline patient characteristics between groups. Transseptal puncture was successful in all patients (57/57, 100%). Total procedure time and duration of transseptal puncture were lower in the F-ICE group (199.4 ± 26.0 minutes vs 150.7 ± 22.1 minutes, P = 0.000; 118.4 ± 19.7 vs 70.5 ± 13.5 minutes, P = 0.000). There was no use of fluoroscopy in the EAM-ICE group (0 mGy vs 70.5 ± 13.5 mGy); the duration of fluoroscopy in the EAM-ICE group was negligible (0 minutes vs 5.4 ± 1.9 minutes). No procedural complication occurred in either group. CONCLUSIONS: EAM-ICE guided zero-fluoroscopy transseptal puncture is an effective and safe procedure.


Asunto(s)
Fibrilación Atrial/cirugía , Tabique Interatrial/diagnóstico por imagen , Cateterismo Cardíaco , Ablación por Catéter , Ecocardiografía , Técnicas Electrofisiológicas Cardíacas , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Beijing , Cateterismo Cardíaco/efectos adversos , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/fisiopatología , Punciones , Radiografía Intervencional , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA