Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Métodos Terapéuticos y Terapias MTCI
Tipo del documento
Intervalo de año de publicación
1.
Artículo en Chino | WPRIM | ID: wpr-985515

RESUMEN

Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.


Asunto(s)
Embarazo , Niño , Humanos , Femenino , Hemoglobina Glucada , Estudios de Cohortes , Diabetes Mellitus/diagnóstico , Sensibilidad y Especificidad , Curva ROC
2.
Chinese Medical Journal ; (24): 391-397, 2005.
Artículo en Inglés | WPRIM | ID: wpr-250921

RESUMEN

<p><b>BACKGROUND</b>Recent studies have indicated that chronic stress may give rise to brain damage, which is related to the genesis of depression. The purpose of this study is to investigate the effects of extract of Ginkgo biloba (EGb) and venlafaxine on depression.</p><p><b>METHODS</b>Rats were treated with chronic and comprehensive stress to create a depression model. Immunohistochemistry was used to detect the expression of brain-derived neurotrophic factor (BDNF) in the hippocampal CA3 neurons of rats treated with different drugs. Behavioral changes of these rats were also examined.</p><p><b>RESULTS</b>The expression of BDNF in the hippocampal CA3 neurons of the depression model decreased with a reduction in exploring behavior and a significant increase in fecal production. The expression of neuron nitric-oxide synthase (nNOS) protein also increased in the rats compared to normal controls. The rats treated with EGb and venlafaxine showed an increase in expression of BDNF and exploring behavior compared to untreated rats, but a decrease in nNOS and fecal production.</p><p><b>CONCLUSIONS</b>Rats sustain damage to the brain after being subjected to chronic and comprehensive stress. Our research has indicated that combined EGb with venlafaxine enhances the protection of neurons and decreases damage to the brain, while relieving the side effects of synthetic antidepressants.</p>


Asunto(s)
Animales , Masculino , Ratas , Antidepresivos de Segunda Generación , Lesiones Encefálicas , Metabolismo , Factor Neurotrófico Derivado del Encéfalo , Ciclohexanoles , Depresión , Quimioterapia , Medicamentos Herbarios Chinos , Ginkgo biloba , Química , Hipocampo , Metabolismo , Fitoterapia , Ratas Wistar , Clorhidrato de Venlafaxina
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA