1.
J Evid Based Integr Med ; 29: 2515690X241241859, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38544476

RESUMEN

BACKGROUND: Pulse width, which can reflect qi, blood excess, and deficiency, has been used for diagnosing diseases and determining the prognosis in traditional Chinese medicine (TCM). This study aimed to devise an objective method to measure the pulse width based on an array pulse diagram for objective diagnosis. METHODS: The channel 6, the region wherein the pulse wave signal is the strongest, is located in the middle of the pulse sensor array and at the guan position of cunkou during data collection. Therefore, the main wave (h1) time of the pulse wave was collected from the channel 6 through calculation. The left h1 time was collected from the remaining 11 channels. The amplitudes at these time points were extracted as the h1 amplitudes for each channel. However, the pulse width could not be calculated accurately at 12 points. Consequently, a bioharmonic spline interpolation algorithm was used to interpolate the h1 amplitude data obtained from the horizontal and vertical points, yielding 651 (31 × 21) h1 amplitude data. The 651 data points were converted into a heat map to intuitively calculate the pulse width. The pulse width was calculated by multiplying the number of grids on the vertical axis with the unit length of the grid. The pulse width was determined by TCM doctors to verify the pulse width measurement accuracy. Meanwhile, a color Doppler ultrasound examination of the volunteers' radial arteries was performed and the intravascular meridian widths of the radial artery compared with the calculated pulse widths to determine the reliability. RESULTS: The pulse width determined using the maximal h1 amplitude method was comparable with the radial artery intravascular meridian widths measured using color Doppler ultrasound. The h1 amplitude was higher in the high blood pressure group and the pulse width was greater. CONCLUSIONS: The pulse width determined using the maximal h1 amplitude was objective and accurate. Comparison between the pulse widths of the normal and high blood pressure groups verified the reliability of the method.


Asunto(s)
Hipertensión , Humanos , Reproducibilidad de los Resultados , Frecuencia Cardíaca , Presión Sanguínea/fisiología , Medicina Tradicional China/métodos
2.
Artículo en Inglés | MEDLINE | ID: mdl-35287309

RESUMEN

Methods: The Tongue and Face Diagnosis Analysis-1 instrument and Pulse Diagnosis Analysis-1 instrument were used to collect the tongue image and sphygmogram of the subhealth fatigue population (n = 252) and disease fatigue population (n = 1160), and we mainly analyzed the tongue and pulse characteristics and constructed the classification model by using the logistic regression method. Results: The results showed that subhealth fatigue people and disease fatigue people had different characteristics of tongue and pulse, and the logistic regression model based on tongue and pulse data had a good classification effect. The accuracies of models of healthy controls and subhealth fatigue, subhealth fatigue and disease fatigue, and healthy controls and disease fatigue were 68.29%, 81.18%, and 84.73%, and the AUC was 0.698, 0.882, and 0.924, respectively. Conclusion: This study provided a new noninvasive method for the fatigue diagnosis from the perspective of objective tongue and pulse data, and the modern tongue diagnosis and pulse diagnosis have good application prospects.

3.
Artículo en Inglés | MEDLINE | ID: mdl-35222674

RESUMEN

Study on the objectivity of pulse diagnosis is inseparable from the instruments to obtain the pulse waves. The single-pulse diagnostic instrument is relatively mature in acquiring and analysing pulse waves, but the pulse information captured by single-pulse diagnostic instrument is limited. The sensor arrays can simulate rich sense of the doctor's fingers and catch multipoint and multiparameter array signals. How to analyse the acquired array signals is still a major problem in the objective research of pulse diagnosis. The goal of this study was to establish methods for analysing arrayed pulse waves and preliminarily apply them in hypertensive disorders. While a sensor array can be used for the real-time monitoring of twelve pulse wave channels, for each subject in this study, only the pulse wave signals of the left hand at the "guan" location were obtained. We calculated the average pulse wave (APW) per channel over a thirty-second interval. The most representative pulse wave (MRPW) and the APW were matched by their correlation coefficient (CC). The features of the MRPW and the features that corresponded to the array pulse volume (APV) parameters were identified manually. Finally, a clinical trial was conducted to detect these feature performance indicators in patients with hypertensive disorders. The independent-samples t-tests and the Mann-Whitney U-tests were performed to assess the differences in these pulse parameters between the healthy and hypertensive groups. We found that the radial passage (RP) APV h1, APV h3, APV h4, APV h3/h1 (P < 0.01), and APV h4/h1 (P < 0.05) were significantly higher in the hypertensive group than in the healthy group; the intermediate passage (IP) APV h4, APV h3/h1 (P < 0.05), and APV h4/h1 (P < 0.01) and the mean APV h3, APV h3/h1 (P < 0.05), and APV h4/h1 (P < 0.01) were significantly higher in the hypertensive group than in the healthy group, and the ulnar passage (UP) APV h4/h1 (P < 0.05) was clearly elevated in the hypertensive group. These results provide a preliminary validation of this novel approach for determining the APV by arrayed pulse wave analysis. In conclusion, we identified effective indicators of hypertensive vascular function. Traditional Chinese medicine (TCM) pulses comprise multidimensional information, and a sensor array could provide a better indication of TCM pulse characteristics. In this study, the validation of the arrayed pulse wave analysis demonstrates that the APV can reliably mirror TCM pulse characteristics.