1.
Pract Lab Med ; 34: e00308, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36713933

RESUMEN

Objectives: Cancer antigen (CA) 72-4 assay is widely used for monitoring gastric and ovarian cancers. The antigen is a mucin-like, tumor-associated glycoprotein known as TAG-72. It has been identified and characterized using two different monoclonal antibodies, CC49 and B72.3, which recognize its glycochain epitopes, Galß(1-3) sialyl-Tn and sialyl-Tn antigens, respectively. This study describes the quantitative analytical performance of a newly developed CA 72-4 assay, ARCHITECT CA 72-4. Design: and Methods: The ARCHITECT CA 72-4 assay was developed using the ARCHITECT i2000SRs and three ARCHITECT i1000SRs. The assay performance was evaluated based on guidance from CLSI (Clinical and Laboratory Standards Institute) and correlation against Elecsys CA 72-4. Results: In the total precision study, the minimum coefficient of variation (CV) for Control/Panel samples over 4 U/mL was 1.1%. The measuring interval was from 0.95 to 200 U/mL with good linearity; and limits of blank (LoB), detection (LoD), and quantitation (LoQ) were 0.09, 0.18, and 0.95 U/mL, respectively. High dose hook effect; differences among specimen tube types; and interference of common drugs, potential cross-reactants, and endogenous substances were not observed. Significantly, this assay has high biotin tolerance at 4875 mg/mL and correlates well with the Elecys CA 72-4 assay (correlation coefficient: 0.95). Conclusions: ARCHITECT CA 72-4 is a highly sensitive and precise assay for CA 72-4 measurement in human sera and plasma.

2.
Clin Chem Lab Med ; 58(8): 1302-1313, 2020 07 28.
Artículo en Inglés | MEDLINE | ID: mdl-32160154

RESUMEN

Background This is a second part of report on the IFCC global multicenter study conducted in Saudi Arabia to derive reference intervals (RIs) for 20 immunoassay analytes including five tumor makers, five reproductive, seven other hormones and three vitamins. Methods A total of 826 apparently healthy individuals aged ≥18 years were recruited in three clinical laboratories located in western, central and eastern Saudi Arabia using the protocol specified for the global study. All serum specimens were measured using Abbott, Architect analyzers. Multiple regression analysis (MRA) was performed to explore sources of variation of each analyte: age, body mass index (BMI), physical exercise and smoking. The magnitude of variation of reference values (RVs) attributable to sex, age and region was calculated by ANOVA as a standard deviation ratio (SDR). RIs were derived by the parametric (P) method. Results MRA revealed that region, smoking and exercise were not relevant sources of variation for any analyte. Based on SDR and actual between-sex differences in upper limits (ULs), we chose to partition RIs by sex for all analytes except for α-fetoprotein and parathyroid hormone (PTH). Age-specific RIs were required in females for ferritin, estradiol, progesterone, testosterone, follitropin, luteotropin and prolactin (PRL). With prominent BMI-related increase, RIs for insulin and C-peptide were derived after excluding individuals with BMI > 32 kg/m2. Individuals taking vitamin D supplements were excluded in deriving RIs for vitamin D and PTH. Conclusions RIs of major immunoassay analytes specific for Saudi Arabians were established in careful consideration of various biological sources of variation.


Asunto(s)
Pruebas de Química Clínica/normas , Inmunoensayo/normas , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valores de Referencia , Arabia Saudita , Adulto Joven
3.
Clin Biochem ; 48(18): 1330-6, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26210849

RESUMEN

OBJECTIVES: Protein induced by vitamin K absence or antagonist II (PIVKA-II), an abnormal form of prothrombin, has been used as an aid in the diagnosis of hepatocellular cancer (HCC) as a tumor marker. We developed a fully automated quantitative immunoassay for PIVKA-II on the ARCHITECT® i systems. The aim of this study was to evaluate the analytical performance of this assay. DESIGN AND METHOD: Assay imprecision, sensitivity, dilution linearity, high dose hook effect, sample type equivalency, assay interferences of potential interfering materials and correlation with Picolumi PIVKA-II (Eidia, Tokyo, Japan) were evaluated. RESULTS: The percentage coefficient of variation (%CV) of total imprecision ranged from 2.8% to 5.4% with 10 levels of samples. The limit of blank (LoB), limit of detection (LoD), and limit of quantitation (LoQ) were less than 0.63 mAU/mL, 1.62 mAU/mL, and 8.25 mAU/mL, respectively. Linearity up to 30,000 mAU/mL, no high dose hook effect, no difference among sample types and no interference of common drugs and endogenous substances were observed. Correlation study with the Picolumi PIVKA-II gave a correlation coefficient of 0.93 and a regression slope of 1.07. CONCLUSIONS: The results demonstrate that the fully automated prototype ARCHITECT PIVKA-II assay is an accurate, highly sensitive and precise assay for the measurement of PIVKA-II levels in human sera and plasmas.


Asunto(s)
Automatización de Laboratorios/normas , Biomarcadores de Tumor/genética , Inmunoensayo/normas , Mediciones Luminiscentes/normas , Precursores de Proteínas/genética , Protrombina/genética , Biomarcadores/sangre , Biomarcadores de Tumor/sangre , Carcinoma Hepatocelular/sangre , Carcinoma Hepatocelular/diagnóstico , Carcinoma Hepatocelular/genética , Expresión Génica , Humanos , Inmunoensayo/instrumentación , Límite de Detección , Neoplasias Hepáticas/sangre , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/genética , Mediciones Luminiscentes/instrumentación , Precursores de Proteínas/sangre
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA