Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.567
Filtrar
Más filtros

Intervalo de año de publicación
1.
Pacing Clin Electrophysiol ; 47(5): 653-660, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38583088

RESUMEN

Atrial tachycardia (AT) is a common rhythm disorder, especially in patients with atrial structural abnormalities. Although voltage mapping can provide a general picture of structural alterations which are mainly secondary to prior ablations, surgery or pressure/volume overload, data is scarce regarding the functional characteristics of low voltage regions in the atrium to predict critical isthmus of ATs. Recently, functional substrate mapping (FSM) emerged as a potential tool to evaluate the functionality of structurally altered regions in the atrium to predict critical sites of reentry. Current evidence suggested a clear association between deceleration zones of isochronal late activation mapping (ILAM) during sinus/paced rhythm and critical isthmus of reentry in patients with left AT. Therefore, these areas seem to be potential ablation targets even not detected during AT. Furthermore, abnormal conduction detected by ILAM may also have a role to identify the potential substrate and predict atrial fibrillation outcome after pulmonary vein isolation. Despite these promising findings, the utility of such an approach needs to be evaluated in large-scale comparative studies. In this review, we aimed to share our experience and review the current literature regarding the use of FSM during sinus/paced rhythm in the prediction of re-entrant ATs and discuss future implications and potential use in patients with atrial low-voltage areas.


Asunto(s)
Atrios Cardíacos , Humanos , Atrios Cardíacos/fisiopatología , Cicatriz/fisiopatología , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas , Taquicardia Supraventricular/cirugía , Taquicardia Supraventricular/fisiopatología , Mapeo del Potencial de Superficie Corporal/métodos
3.
Curr Protoc ; 4(2): e994, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38372479

RESUMEN

Cardiac arrhythmias are a common cardiac condition that might lead to fatal outcomes. A better understanding of the molecular and cellular basis of arrhythmia mechanisms is necessary for the development of better treatment modalities. To aid these efforts, various mouse models have been developed for studying cardiac arrhythmias. Both genetic and surgical mouse models are commonly used to assess the incidence and mechanisms of arrhythmias. Since spontaneous arrhythmias are uncommon in healthy young mice, intracardiac programmed electrical stimulation (PES) can be performed to assess the susceptibility to pacing-induced arrhythmias and uncover the possible presence of a proarrhythmogenic substrate. This procedure is performed by positioning an octopolar catheter inside the right atrium and ventricle of the heart through the right jugular vein. PES can provide insights into atrial and ventricular electrical activity and reveal whether atrial and/or ventricular arrhythmias are present or can be induced. Here, we explain detailed procedures used to perform this technique, possible troubleshooting scenarios, and methods to interpret the results obtained. © 2024 Wiley Periodicals LLC. Basic Protocol: Programmed electrical stimulation in mice.


Asunto(s)
Arritmias Cardíacas , Técnicas Electrofisiológicas Cardíacas , Ratones , Animales , Arritmias Cardíacas/terapia , Ventrículos Cardíacos , Atrios Cardíacos , Estimulación Eléctrica
4.
Cardiovasc Eng Technol ; 15(1): 52-64, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-37962813

RESUMEN

In clinical rhythmology, intracardiac bipolar electrograms (EGMs) play a critical role in investigating the triggers and substrates inducing and perpetuating atrial fibrillation (AF). However, the interpretation of bipolar EGMs is ambiguous due to several aspects of electrodes, mapping algorithms and wave propagation dynamics, so it requires several variables to describe the effects of these uncertainties on EGM analysis. In this narrative review, we critically evaluate the potential impact of such uncertainties on the design of cardiac mapping tools on AF-related substrate characterization. Literature suggest uncertainties are due to several variables, including the wave propagation vector, the wave's incidence angle, inter-electrode spacing, electrode size and shape, and tissue contact. The preprocessing of the EGM signals and mapping density will impact the electro-anatomical representation and the features extracted from the local electrical activities. The superposition of multiple waves further complicates EGM interpretation. The inclusion of these uncertainties is a nontrivial problem but their consideration will yield a better interpretation of the intra-atrial dynamics in local activation patterns. From a translational perspective, this review provides a concise but complete overview of the critical variables for developing more precise cardiac mapping tools.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Atrios Cardíacos , Técnicas Electrofisiológicas Cardíacas , Electrofisiología Cardíaca
5.
J Interv Card Electrophysiol ; 67(2): 303-317, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37354370

RESUMEN

BACKGROUND: Real-time phase mapping (ExTRa™) is useful in determining the strategy of catheter ablation for non-paroxysmal atrial fibrillation (AF). This study aimed to investigate the features of drivers of AF associated with its termination during ablation. METHODS: Thirty-six patients who underwent catheter ablation for non-paroxysmal AF using online real-time phase mapping (ExTRa™) were enrolled. A significant AF driver was defined as an area with a non-passively activated ratio of ≥ 50% on mapping analysis in the left atrium (LA). All drivers were simultaneously evaluated using a low-voltage area, complex fractionated atrial electrogram (CFAE), and rotational activity by unipolar electrogram analysis. The electrical characteristics of drivers were compared between patients with and without AF termination during the procedure. RESULTS: Twelve patients achieved AF termination during the procedure. The total number of drivers detected on the mapping was significantly lower (4.4 ± 1.6 vs. 7.4 ± 3.8, p = 0.007), and the drivers were more concentrated in limited LA regions (2.8 ± 0.9 vs. 3.9 ± 1.4, p = 0.009) in the termination group than in the non-termination group. The presence of drivers 2-6 with limited (≤ 3) LA regions showed a tenfold increase in the likelihood of AF termination, with 83% specificity and 67% sensitivity. Among 231 AF drivers, the drivers related to termination exhibited a greater overlap of CFAE (56.8 ± 34.1% vs. 39.5 ± 30.4%, p = 0.004) than the non-related drivers. The termination group showed a trend toward a lower recurrence rate after ablation (p = 0.163). CONCLUSIONS: Rotors responsible for AF maintenance may be characterized in cases with concentrated regions and fewer drivers on mapping.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/cirugía , Atrios Cardíacos/cirugía , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Resultado del Tratamiento
6.
Pacing Clin Electrophysiol ; 47(1): 28-35, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38029377

RESUMEN

BACKGROUND: Recently, a new OCTARAY® mapping catheter was commercially launched. The catheter is designed to enable high-density mapping and precise signal recording via 48 small electrodes arranged on eight radiating splines. The purpose of this study was to compare bipolar voltage and low-voltage-area size, and mapping efficacy between the OCTARAY catheter and the PENTARAY® catheter METHODS: Twelve consecutive patients who underwent initial and second ablations for persistent atrial fibrillation within 2 years were considered for enrollment. Voltage mapping was performed twice, first during the initial ablation using the PENTARY catheter and second during the second ablation using the OCTARAY Long 3-3-3-3-3 (L3) catheter. RESULTS: Mean voltage with the OCTARAY-L3 catheter (1.64 ± 0.57 mV) was 32.3% greater than that with the PENTARAY catheter (1.24 ± 0.46 mV, p < .0001) in total left atrium. Low-voltage-area (<0.50 mV) size with the OCTARAY-L3 catheter was smaller than that with the PENTARAY catheter (6.9 ± 9.7 vs. 11.4 ± 13.0 cm2 , p < .0001). The OCTARAY-L3 catheter demonstrated greater efficacy than the PENTARAY catheter in terms of shorter mapping time (606 ± 99 vs. 782 ± 211 s, p = .008) and more mapping points (3,026 ± 838 vs. 781 ± 342 points, p < .0001). CONCLUSION: The OCTARAY catheter demonstrated higher voltage recordings, narrower low-voltage areas, and a more efficacious mapping procedure than the PENTARAY catheter.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Técnicas Electrofisiológicas Cardíacas , Ablación por Catéter/métodos , Fibrilación Atrial/cirugía , Atrios Cardíacos , Catéteres
7.
Europace ; 25(11)2023 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-37961921

RESUMEN

AIMS: The aim of our study was to analyse the response to short-coupled atrial extrastimuli to identify areas of hidden slow conduction (HSC) and their relationship with the atrial fibrillation (AF) phenotype. METHODS AND RESULTS: Twenty consecutive patients with paroxysmal AF and persistent AF (10:10) underwent the first pulmonary vein isolation procedure. Triple short-coupled extrastimuli were delivered in sinus rhythm (SR), and the evoked response was analysed: sites exhibiting double or highly fragmented electrograms (EGM) were defined as positive for HSC (HSC+). The delta of the duration of the bipolar EGM was analysed, and bipolar EGM duration maps were built. High-density maps were acquired using a multipolar catheter during AF, SR, and paced rhythm. Spatial co-localization of HSC+ and complex fractionated atrial EGMs (CFAE) during AF was evaluated. Persistent AF showed a higher number and percentage of HSC+ than paroxysmal AF (13.9% vs. 3.3%, P < 0.001). The delta of EGM duration was 53 ± 22 ms for HSC+ compared with 13 ± 11 (10) ms in sites with negative HSC (HSC-) (P < 0.001). The number and density of HSC+ were lower than CFAE during AF (19 vs. 56 per map, P < 0.001). The reproducibility and distribution of HSC+ in repeated maps were superior to CFAE (P = 0.19 vs. P < 0.001). Sites with negative and positive responses showed a similar bipolar voltage in the preceding sinus beat (1.65 ± 1.34 and 1.48 ± 1.47 mV, P = 0.12). CONCLUSION: Functional mapping identifies more discrete and reproducible abnormal substrates than mapping during AF. The HSC+ sites in response to triple extrastimuli are more frequent in persistent AF than in paroxysmal AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Reproducibilidad de los Resultados , Técnicas Electrofisiológicas Cardíacas/métodos , Frecuencia Cardíaca , Atrios Cardíacos
8.
Pacing Clin Electrophysiol ; 46(11): 1341-1347, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37846820

RESUMEN

To provide an overview of the current application of high-density mapping (HDM) in the mechanism of complex atrial tachycardias (ATs). Complex ATs are frequently scar-related, after history of previous cardiac surgery and large scars. These scar-related ATs are difficult to manage medically and frequently recur after electrical cardioversion. HDM technologies have enabled rigorous elucidation of AT mechanisms in patients post cardiac surgery. This article showed the application of HDM technology in complex ATs from the mechanisms of complex ATs, the development of HDM technology, and the identification of scars or critical isthmus from HDM. HDM-guided approach is highly effective for identifying the ATs mechanism and critical isthmus.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Ablación por Catéter , Taquicardia Supraventricular , Humanos , Cicatriz , Técnicas Electrofisiológicas Cardíacas , Taquicardia Supraventricular/cirugía , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Resultado del Tratamiento , Atrios Cardíacos
9.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37470443

RESUMEN

AIMS: Electro-anatomical mapping may be critical to identify atrial fibrillation (AF) subjects who require substrate modification beyond pulmonary vein isolation (PVI). The objective was to determine correlations between pre-ablation mapping characteristics and 12-month outcomes after a single PVI-only catheter ablation of AF. METHODS AND RESULTS: This study enrolled paroxysmal AF (PAF), early persistent AF (PsAF; 7 days-3 months), and non-early PsAF (>3-12 months) subjects undergoing de novo PVI-only radiofrequency catheter ablation. Sinus rhythm (SR) and AF voltage maps were created with the Advisor HD Grid™ Mapping Catheter, Sensor Enabled™ for each subject, and the presence of low-voltage area (LVA) (low-voltage cutoffs: 0.1-1.5 mV) was investigated. Follow-up visits were at 3, 6, and 12 months, with a 24-h Holter monitor at 12 months. A Cox proportional hazards model identified associations between mapping data and 12-month recurrence after a single PVI procedure. The study enrolled 300 subjects (113 PAF, 86 early PsAF, and 101 non-early PsAF) at 18 centres. At 12 months, 75.5% of subjects were free from AF/atrial flutter (AFL)/atrial tachycardia (AT) recurrence. Univariate analysis found that arrhythmia recurrence did not correlate with AF diagnosis, but LVA was significantly correlated. Low-voltage area (<0.5 mV) >28% of the left atrium in SR [hazard ratio (HR): 4.82, 95% confidence interval (CI): 2.08-11.18; P = 0.0003] and >72% in AF (HR: 5.66, 95% CI: 2.34-13.69; P = 0.0001) was associated with a higher risk of AF/AFL/AT recurrence at 12 months. CONCLUSION: Larger extension of LVA was associated with an increased risk of arrhythmia recurrence. These subjects may benefit from substrate modification beyond PVI.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Frecuencia Cardíaca , Resultado del Tratamiento , Técnicas Electrofisiológicas Cardíacas , Recurrencia , Factores de Tiempo , Atrios Cardíacos , Aleteo Atrial/diagnóstico , Aleteo Atrial/cirugía , Aleteo Atrial/etiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
10.
Vet Med Sci ; 9(5): 1973-1979, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37491011

RESUMEN

Three dogs were diagnosed with right atrial thrombosis, thought to be secondary to systemic diseases. Specifically, two cases had hyperadrenocorticism and one case was diagnosed with pancreatitis with acute renal injury. In all cases, the thrombi were found within the right atrium, necessitating a differentiation from cardiac neoplasia. In all three cases, the structures assumed to be thrombi had irregular margins with interspersed hypoechoic regions, which were later confirmed as thrombi based on the responsiveness to therapy. All three cases were prescribed with the combination of clopidogrel and rivaroxaban.The thrombi gradually disappeared after initiation of the combination therapy. Complete resolution of right atrial thrombosis was noted in each dog treated with clopidogrel and rivaroxaban. This combination therapy appears to be safe and well tolerated. Diligent observation of the echocardiographic findings and clinical course allows the diagnosis of thrombosis.


Asunto(s)
Fibrilación Atrial , Enfermedades de los Perros , Cardiopatías , Trombosis , Perros , Animales , Fibrinolíticos/uso terapéutico , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/veterinaria , Rivaroxabán/uso terapéutico , Clopidogrel/uso terapéutico , Estudios de Seguimiento , Cardiopatías/diagnóstico por imagen , Cardiopatías/tratamiento farmacológico , Cardiopatías/veterinaria , Ecocardiografía/veterinaria , Atrios Cardíacos/diagnóstico por imagen , Trombosis/diagnóstico por imagen , Trombosis/tratamiento farmacológico , Trombosis/veterinaria , Enfermedades de los Perros/diagnóstico por imagen , Enfermedades de los Perros/tratamiento farmacológico
11.
JACC Clin Electrophysiol ; 9(7 Pt 2): 1082-1096, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37495319

RESUMEN

BACKGROUND: Dominant frequencies (DFs) or complex fractionated atrial electrograms (CFAEs), indicative of focal sources or rotational activation, are used to identify target sites for atrial fibrillation (AF) ablation in clinical studies, although the relationship among DF, CFAE, and activation patterns remains unclear. OBJECTIVES: This study sought to investigate the relationship between patterns of activation underlying DF and CFAE sites during AF. METHODS: Epicardial high-resolution mapping of the right and left atrium including Bachmann's bundle was performed in 71 participants. We identified the highest dominant frequency (DFmax) and highest degree of CFAE (CFAEmax) with the use of existing clinical criteria and classified patterns of activation as focal or rotational activation and smooth propagation, conduction block (CB), collision and remnant activity, and fibrillation potentials as single, double, or fractionated potentials containing, respectively, 1, 2, or 3 or more negative deflections. Relationships among activation patterns, DFmax, and potential types were investigated. RESULTS: DFmax were primarily located at the left atrioventricular groove and did not harbor focal activation (proportion focal waves: 0% [IQR: 0%-2%]). Compared with non-DFmax sites, DFmax were characterized by more frequent smooth propagation (22% [IQR: 7%-48%] vs 17% [IQR: 11%-24%]; P = 0.001), less frequent conduction block (69% [IQR: 51%-81%] vs 74% [IQR: 69%-78%]; P = 0.006), a higher proportion of single potentials (72% [IQR: 55%-84%] vs 6%1 [IQR: 55%-65%]; P = 0.003), and a lower proportion of fractionated potentials (4% [IQR: 1%-11%] vs 12% [IQR: 9%-15%]; P = 0.004). CFAEmax were mainly found at the pulmonary veins area, and only 1% [IQR: 0%-2%] of all CFAEmax contained focal activation. Compared with non-CFAEmax sites, CFAEmax sites were characterized by less frequent smooth propagation (1% [IQR: 0%-1%] vs 17% [IQR: 12%-24%]; P < 0.001) and more frequent remnant activity (20% [IQR: 12%-29%] vs 8% [IQR: 5%-10%]; P < 0.001), and harbored predominantly fractionated potentials (52% [IQR: 43%-66%] vs 12% [IQR: 9%-14%]; P < 0.001). CONCLUSIONS: Focal or rotational patterns of activation were not consistently detected at DFmax domains and CFAEmax sites. These findings do not support the concept of targeting DFmax or CFAEmax according to existing criteria for AF ablation.


Asunto(s)
Fibrilación Atrial , Humanos , Fibrilación Atrial/cirugía , Atrios Cardíacos , Técnicas Electrofisiológicas Cardíacas , Mapeo Epicárdico , Nodo Atrioventricular , Bloqueo Cardíaco
12.
Altern Ther Health Med ; 29(7): 160-165, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37442191

RESUMEN

Objective: This study aimed to analyze the clinical significance of body mass index (BMI), mean platelet volume (MPV), and left atrial structure in the recurrence of atrial fibrillation (AF) after treatment with catheter radiofrequency ablation. Methods: A total of 69 patients with AF who underwent catheter radiofrequency ablation at Beijing Anzhen Hospital from January 2020 to July 2021 (research group) were compared to 75 patients who underwent physical examination during the same period (control group). MPV levels were measured before and after treatment in both groups. Additionally, height and weight measurements were used to calculate BMI, while left atrial anteroposterior diameter, left atrial volume, and left atrial volume index were recorded using cardiac ultrasonography. Results: The research group exhibited higher BMI, MPV, left atrial anteroposterior diameter, left atrial volume, and left atrial volume index compared to the control group, and these parameters decreased after treatment (P < .05). Prognostic follow-up revealed that patients with AF recurrence had higher values for these parameters than those without recurrence (P < .05). Receiver Operating Characteristic analysis indicated that all these parameters had good predictive value for prognostic recurrence of AF (P < .05). Logistic regression analysis demonstrated that all the parameters were independent risk factors for prognostic atrial fibrillation recurrence (P < .05). Conclusions: BMI, MPV, and left atrial structure are associated with the occurrence and development of atrial fibrillation. These parameters provide an excellent assessment of the prognosis for AF recurrence after catheter radiofrequency ablation treatment. Monitoring changes in BMI, MPV, and left atrial structure in atrial fibrillation patients can contribute to more reliable prognostic information in clinical settings.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/cirugía , Índice de Masa Corporal , Volúmen Plaquetario Medio , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Ablación por Catéter/efectos adversos , Recurrencia , Resultado del Tratamiento
13.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37428890

RESUMEN

AIMS: Although the mechanism of an atrial tachycardia (AT) can usually be elucidated using modern high-resolution mapping systems, it would be helpful if the AT mechanism and circuit could be predicted before initiating mapping. OBJECTIVE: We examined if the information gathered from the cycle length (CL) of the tachycardia can help predict the AT-mechanism and its localization. METHODS: One hundred and thirty-eight activation maps of ATs including eight focal-ATs, 94 macroreentrant-ATs, and 36 localized-ATs in 95 patients were retrospectively reviewed. Maximal CL (MCL) and minimal CL (mCL) over a minute period were measured via a decapolar catheter in the coronary sinus. CL-variation and beat-by-beat CL-alternation were examined. Additionally, the CL-respiration correlation was analysed by the RhythmiaTM system. : Both MCL and mCL were significantly shorter in macroreentrant-ATs [MCL = 288 (253-348) ms, P = 0.0001; mCL = 283 (243-341) ms, P = 0.0012], and also shorter in localized-ATs [MCL = 314 (261-349) ms, P = 0.0016; mCL = 295 (248-340) ms, P = 0.0047] compared to focal-ATs [MCL = 506 (421-555) ms, mCL = 427 (347-508) ms]. An absolute CL-variation (MCL-mCL) < 24 ms significantly differentiated re-entrant ATs from focal-ATs with a sensitivity = 96.9%, specificity = 100%, positive predictive value (PPV) = 100%, and negative predictive value (NPV) = 66.7%. The beat-by-beat CL-alternation was observed in 10/138 (7.2%), all of which showed the re-entrant mechanism, meaning that beat-by-beat CL-alternation was the strong sign of re-entrant mechanism (PPV = 100%). Although the CL-respiration correlation was observed in 28/138 (20.3%) of ATs, this was predominantly in right-atrium (RA)-ATs (24/41, 85.7%), rather than left atrium (LA)-ATs (4/97, 4.1%). A positive CL-respiration correlation highly predicted RA-ATs (PPV = 85.7%), and negative CL-respiration correlation probably suggested LA-ATs (NPV = 84.5%). CONCLUSION: Detailed analysis of the tachycardia CL helps predict the AT-mechanism and the active AT chamber before an initial mapping.


Asunto(s)
Ablación por Catéter , Taquicardia Supraventricular , Humanos , Estudios Retrospectivos , Técnicas Electrofisiológicas Cardíacas , Taquicardia , Atrios Cardíacos , Resultado del Tratamiento
14.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37477953

RESUMEN

BACKGROUND AND AIMS: Atrial extrasystoles (AES) provoke conduction disorders and may trigger episodes of atrial fibrillation (AF). However, the direction- and rate-dependency of electrophysiological tissue properties on epicardial unipolar electrogram (EGM) morphology is unknown. Therefore, this study examined the impact of spontaneous AES on potential amplitude, -fractionation, -duration, and low-voltage areas (LVAs), and correlated these differences with various degrees of prematurity and aberrancy. METHODS AND RESULTS: Intra-operative high-resolution epicardial mapping of the right and left atrium, Bachmann's Bundle, and pulmonary vein area was performed during sinus rhythm (SR) in 287 patients (60 with AF). AES were categorized according to their prematurity index (>25% shortening) and degree of aberrancy (none, mild/opposite, moderate and severe). In total, 837 unique AES (457 premature; 58 mild/opposite, 355 moderate, and 154 severe aberrant) were included. The average prematurity index was 28% [12-45]. Comparing SR and AES, average voltage decreased (-1.1 [-1.2, -0.9] mV, P < 0.001) at all atrial regions, whereas the amount of LVAs and fractionation increased (respectively, +3.4 [2.7, 4.1] % and +3.2 [2.6, 3.7] %, P < 0.001). Only weak or moderate correlations were found between EGM morphology parameters and prematurity indices (R2 < 0.299, P < 0.001). All parameters were, however, most severely affected by either mild/opposite or severely aberrant AES, in which the effect was more pronounced in AF patients. Also, there were considerable regional differences in effects provoked by AES. CONCLUSION: Unipolar EGM characteristics during spontaneous AES are mainly directional-dependent and not rate-dependent. AF patients have more direction-dependent conduction disorders, indicating enhanced non-uniform anisotropy that is uncovered by spontaneous AES.


Asunto(s)
Fibrilación Atrial , Complejos Atriales Prematuros , Mapeo Epicárdico , Humanos , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos/diagnóstico por imagen
15.
Eur Heart J ; 44(35): 3339-3353, 2023 09 14.
Artículo en Inglés | MEDLINE | ID: mdl-37350738

RESUMEN

BACKGROUND AND AIMS: This study aimed to histologically validate atrial structural remodelling associated with atrial fibrillation. METHODS AND RESULTS: Patients undergoing atrial fibrillation ablation and endomyocardial atrial biopsy were included (n = 230; 67 ± 12 years old; 69 women). Electroanatomic mapping was performed during right atrial pacing. Voltage at the biopsy site (Vbiopsy), global left atrial voltage (VGLA), and the proportion of points with fractionated electrograms defined as ≥5 deflections in each electrogram (%Fractionated EGM) were evaluated. SCZtotal was calculated as the total width of slow conduction zones, defined as regions with a conduction velocity of <30 cm/s. Histological factors potentially associated with electroanatomic characteristics were evaluated using multiple linear regression analyses. Ultrastructural features and immune cell infiltration were evaluated by electron microscopy and immunohistochemical staining in 33 and 60 patients, respectively. Fibrosis, intercellular space, myofibrillar loss, and myocardial nuclear density were significantly associated with Vbiopsy (P = .014, P < .001, P < .001, and P = .002, respectively) and VGLA (P = .010, P < .001, P = .001, and P < .001, respectively). The intercellular space was associated with the %Fractionated EGM (P = .001). Fibrosis, intercellular space, and myofibrillar loss were associated with SCZtotal (P = .028, P < .001, and P = .015, respectively). Electron microscopy confirmed plasma components and immature collagen fibrils in the increased intercellular space and myofilament lysis in cardiomyocytes, depending on myofibrillar loss. Among the histological factors, the severity of myofibrillar loss was associated with an increase in macrophage infiltration. CONCLUSION: Histological correlates of atrial structural remodelling were fibrosis, increased intercellular space, myofibrillar loss, and decreased nuclear density. Each histological component was defined using electron microscopy and immunohistochemistry studies.


Asunto(s)
Fibrilación Atrial , Remodelación Atrial , Ablación por Catéter , Humanos , Femenino , Persona de Mediana Edad , Anciano , Fibrilación Atrial/cirugía , Técnicas Electrofisiológicas Cardíacas/métodos , Atrios Cardíacos , Frecuencia Cardíaca , Fibrosis
16.
J Cardiovasc Electrophysiol ; 34(8): 1613-1621, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37365931

RESUMEN

INTRODUCTION: Improved sinus rhythm (SR) maintenance rates have been achieved in patients with persistent atrial fibrillation (AF) undergoing pulmonary vein isolation plus additional ablation of low voltage substrate (LVS) during SR. However, voltage mapping during SR may be hindered in persistent and long-persistent AF patients by immediate AF recurrence after electrical cardioversion. We assess correlations between LVS extent and location during SR and AF, aiming to identify regional voltage thresholds for rhythm-independent delineation/detection of LVS areas. (1) Identification of voltage dissimilarities between mapping in SR and AF. (2) Identification of regional voltage thresholds that improve cross-rhythm substrate detection. (3) Comparison of LVS between SR and native versus induced AF. METHODS: Forty-one ablation-naive persistent AF patients underwent high-definition (1 mm electrodes; >1200 left atrial (LA) mapping sites per rhythm) voltage mapping in SR and AF. Global and regional voltage thresholds in AF were identified which best match LVS < 0.5 mV and <1.0 mV in SR. Additionally, the correlation between SR-LVS with induced versus native AF-LVS was assessed. RESULTS: Substantial voltage differences (median: 0.52, interquartile range: 0.33-0.69, maximum: 1.19 mV) with a predominance of the posterior/inferior LA wall exist between the rhythms. An AF threshold of 0.34 mV for the entire left atrium provides an accuracy, sensitivity and specificity of 69%, 67%, and 69% to identify SR-LVS < 0.5 mV, respectively. Lower thresholds for the posterior wall (0.27 mV) and inferior wall (0.3 mV) result in higher spatial concordance to SR-LVS (4% and 7% increase). Concordance with SR-LVS was higher for induced AF compared to native AF (area under the curve[AUC]: 0.80 vs. 0.73). AF-LVS < 0.5 mV corresponds to SR-LVS < 0.97 mV (AUC: 0.73). CONCLUSION: Although the proposed region-specific voltage thresholds during AF improve the consistency of LVS identification as determined during SR, the concordance in LVS between SR and AF remains moderate, with larger LVS detection during AF. Voltage-based substrate ablation should preferentially be performed during SR to limit the amount of ablated atrial myocardium.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos/cirugía
17.
Ann Med ; 55(1): 1431-1441, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37194486

RESUMEN

BACKGROUND: It is unknown which features of unipolar atrial electrogram (U-AEGM) morphology are affected by ageing and whether age-related changes in U-AEGM morphology are equally distributed throughout the right and left atria. PATIENTS AND METHODS: Epicardial high-resolution mapping was performed in patients undergoing coronary artery bypass grafting surgery during sinus rhythm (SR). Mapping areas include the right atrium (RA), left atrium (LA), pulmonary vein area (PVA) and Bachmann's bundle (BB). Patients were categorized into a young (age < 60) and aged (age ≥ 60) group. U-AEGM were classified as single potentials (SPs, one deflection), short double potentials (SDPs, deflection interval ≤ 15ms), long double potentials (LDPs, deflection interval > 15ms) and fractionated potentials (FPs, ≥3 deflections). RESULTS: A total of 213 patients (age: 67 (59-73) years; young group N = 58, aged group N = 155) were included. Only at BB, the proportion of SPs (p = 0.007) was significantly higher in the young group, while the proportion of SDPs (p = 0.051), LDPs (p = 0.004) and FPs (p = 0.006) was higher in the aged group. After adjusting for potential confounders, older age was associated with a reduction in SPs [regression coefficient (ß): -6.33, 95% confident interval (CI): -10.37 to -2.30] at the expense of an increased proportion of SDPs (ß: 2.49, 95% CI: 0.09 to 4.89), LDPs (ß: 1.94, 95% CI: 0.21 to 3.68) and FPs (ß: 1.90, 95% CI: 0.62 to 3.18). CONCLUSIONS: Age-related remodeling particularly affects BB as indicated by the decreased amount of non-SP at this location in the elderly.Key MessagesAgeing preferentially affects the morphology of unipolar atrial electrograms recorded at Bachmann's bundle.At Bachmann's bundle, the proportion of short double-, long double- and fractionated potentials increase during ageing at the expense of a decrease in the proportion of single potentials, reflecting aggravation of abnormalities in conduction.The increase in abnormal unipolar atrial electrograms at Bachmann's bundle during ageing supports the concept that Bachmann's bundle may play an important role in development of age-related arrhythmias such as atrial fibrillation.


Asunto(s)
Fibrilación Atrial , Mapeo Epicárdico , Anciano , Humanos , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos , Frecuencia Cardíaca
18.
Circ J ; 87(7): 973-981, 2023 06 23.
Artículo en Inglés | MEDLINE | ID: mdl-37258220

RESUMEN

BACKGROUND: An epicardial connection (EC) between the right-sided pulmonary venous (RtPV) carina and right atrium (RA) may preclude PV isolation, but its electrophysiological role during atrial fibrillation (AF) remains unknown.Methods and Results: This prospective observational study included 98 consecutive patients undergoing catheter ablation for AF, subdivided into the EC group (n=17) and non-EC group (n=80) based on observation of RA posterior wall breakthrough during RtPV pacing. Mean left atrial (LA) dominant frequency (mean DFLA) was defined as the averaged DFs at the right and left PVs and LA appendage. The regional DF was higher in the EC group vs. the non-EC group except at the left PV antrum. The DF at the RA appendage (RAA) and mean DFLAwere equivocal (6.5±0.7 vs. 6.6±0.7 Hz) in the EC group, but the mean DFLAwas significantly higher than that at the RAA (5.8±0.6 vs. 6.1±0.5 Hz, P=0.001) in the non-EC group, suggesting an LA-to-RA DF gradient. A significant correlation of DF between the RtPV antrum and RAA was observed in the EC group (P<0.001, r=0.84) but not in the non-EC group. CONCLUSIONS: An electrophysiological link via interatrial ECs might attenuate the hierarchical nature of activation frequencies of AF, leading to advanced electrical remodeling of the atria.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Atrios Cardíacos , Venas Pulmonares/cirugía , Técnicas Electrofisiológicas Cardíacas/métodos , Ablación por Catéter/métodos
19.
JACC Clin Electrophysiol ; 9(8 Pt 2): 1500-1512, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37204357

RESUMEN

BACKGROUND: Optimal method for voltage assessment in AF remains unclear. OBJECTIVES: This study evaluated different methods for assessing atrial voltage and their accuracy in identifying pulmonary vein reconnection sites (PVRSs) in atrial fibrillation (AF). METHODS: Patients with persistent AF undergoing ablation were included. De novo procedures: voltage assessment in AF with omnipolar voltage (OV) and bipolar voltage (BV) methodology and BV assessment in sinus rhythm (SR). Activation vector and fractionation maps were reviewed at voltage discrepancy sites on OV and BV maps in AF. AF voltage maps were compared with SR BV maps. Repeat ablation procedures: OV and BV maps in AF were compared to detect gaps in wide area circumferential ablation (WACA) lines that correlated with PVRS. RESULTS: Forty patients were included: 20 de novo and 20 repeat procedures. De novo procedure: OV vs BV maps in AF; average voltage 0.55 ± 0.18 mV vs 0.38 ± 0.12 mV; P = 0.002, voltage difference of 0.20 ± 0.07 mV; P = 0.003 at coregistered points and proportion of left atrium (LA) area occupied by low-voltage zones (LVZs) was smaller on OV maps (42.4% ± 12.8% OV vs 66.7% ± 12.7% BV; P < 0.001). LVZs identified on BV maps and not on OV maps correlated frequently to wavefront collision and fractionation sites (94.7%). OV AF maps agreed better with BV SR maps (voltage difference at coregistered points 0.09 ± 0.03 mV; P = 0.24) unlike BV AF maps (0.17 ± 0.07 mV, P = 0.002). Repeat ablation procedure: OV was superior in identifying WACA line gaps that correlated with PVRS than BV maps (area under the curve = 0.89, P < 0.001). CONCLUSIONS: OV AF maps improve voltage assessment by overcoming the impact of wavefront collision and fractionation. OV AF maps correlate better with BV maps in SR and more accurately delineate gaps on WACA lines at PVRS.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Cicatriz/patología , Técnicas Electrofisiológicas Cardíacas/métodos , Ablación por Catéter/métodos , Atrios Cardíacos
20.
Basic Clin Pharmacol Toxicol ; 133(2): 179-193, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37177881

RESUMEN

Post-operative atrial fibrillation (POAF) is the most common complication after cardiac surgery. Despite implementation of several pharmacological strategies, incidence of POAF remains at approximately 30%. An adenovirus vector encoding KCNH2-G628S has proven efficacious in a porcine model of AF. In this preclinical study, 1.5 × 1010 or 1.5 × 1012 Ad-KCNH2-G628S vector particles (vp) were applied to the atrial epicardium or 1.5 × 1012 vp were applied to the whole epicardial surface of New Zealand White rabbits. Saline and vector vehicle served as procedure controls. Animals were followed for up to 42 days. Vector genomes persisted in the atria up to 42 days, with no distribution to extra-thoracic organs. There were no adverse effects attributable to test article on standard toxicological endpoints or on blood pressure, left atrial or ventricular ejection fractions, electrocardiographic parameters, or serum IL-6 or troponin concentrations. Mononuclear infiltration of the myocardium of the atrial free walls of low-dose, but not high-dose animals was observed at 7 and 21 days, but these changes did not persist or affect cardiac function. After scaling for heart size, results indicate the test article is safe at doses up to 25 times the maximum proposed for the human clinical trial.


Asunto(s)
Fibrilación Atrial , Procedimientos Quirúrgicos Cardíacos , Conejos , Humanos , Animales , Porcinos , Distribución Tisular , Atrios Cardíacos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Miocardio , Complicaciones Posoperatorias/etiología , Canal de Potasio ERG1
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA